• Wholesale Price Soil Ph Sensor - Rain sensor stainless steel outdoor hydrological station – Huacheng

Wholesale Price Soil Ph Sensor - Rain sensor stainless steel outdoor hydrological station – Huacheng

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We keep on with our enterprise spirit of "Quality, Efficiency, Innovation and Integrity". We intention to create extra worth for our buyers with our prosperous resources, superior machinery, experienced workers and superb services for Barometric Measurement, Sensor Air Temperature, Pipette Straw, Through more than 8 years of business, we have accumulated rich experience and advanced technologies in the production of our products.
Wholesale Price Soil Ph Sensor - Rain sensor stainless steel outdoor hydrological station – Huacheng Detail:

Water-carrying caliber Ф200 ± 0.6mm
Measuring range ≤4mm / min (precipitation intensity)
Resolution 0.2mm (6.28ml)
Accuracy ± 4% (indoor static test, rain intensity is 2mm / min)
Power supply mode DC 5V 
DC 12V 
DC 24V 
Other
Output form Current 4 ~ 20mA
Switching signal: On-off of reed switch
Voltage: 0~2.5V 
Voltage: 0~5V    
Voltage 1 ~ 5V
Other
Instrument line length Standard: 5 meters
Other
Working temperature 0 ~ 50 ℃
Storage temperature -10 ℃ ~ 50 ℃

1. If equipped with a weather station produced by the company, directly connect the sensor to the corresponding interface on the weather station using a sensor line;

2. If the sensor is purchased separately, as the sensor outputs a set of switching signals, the cable connector does not matter positive and negative. Connect the sensor to the circuit as shown in the figure.

lf-0004-rain

If the sensor outputs other signals, the corresponding line sequence and function of the conventional sensor are as follows:

Line color Output signal
Voltage Current communication
Red Power + Power + Power +
Black(green) Power ground Power ground Power ground
Yellow Voltage signal Current signal A+/TX
Blue     B-/RX

lf-0004-rain1

Structure Dimensions 

lf-0004-rain2

Transmitter size  

1. the serial format
Data bits 8 bits
Stop bit 1 or 2
Check Digit None
Baud rate 9600 Communication interval is at least 1000ms
2. Communication format
[1] Write device address
Send: 00 10 Adress CRC (5 bytes)
Returns: 00 10 CRC (4 bytes)
Note: 1. The address bit of the read and write address command must be 00.
2. Adress is 1 byte and the range is 0-255.
Example: Send 00 10 01 BD C0
Returns 00 10 00 7C
[2] Read device address
Send: 00 20 CRC (4 bytes)
Returns: 00 20 Adress CRC (5 bytes)
Explanation: Adress is 1 byte, the range is 0-255
For example: Send 00 20 00 68
Returns 00 20 01 A9 C0
[3] Read real-time data
Send: Adress 03 00 00 00 01 XX XX
Note: as shown below:

Code Function definition Note
Adress Station number (address)  
03 Function code  
00  00 Initial address  
00  01 Read points  
XX XX CRC Check code,front low later high  

Returns: Adress 03 02 XX XX XX XX YY YY
Note

Code Function definition Note
Adress Station number (address)  
03 Function code  
02 Read unit byte  
XX  XX Data (high before, low after) Hex
XX  XX CRCCheck code  

To calculate the CRC code:
1. The preset 16-bit register is FFFF in hexadecimal (that is, all are 1). Call this register the CRC register.
2. XOR the first 8-bit data with the lower bit of the 16-bit CRC register and put the result in the CRC register.
3. Shift the contents of the register to the right by one bit (toward the low bit), fill the highest bit with 0, and check the lowest bit。
4. If the least significant bit is 0: repeat step 3 (shift again), if the least significant bit is 1: the CRC register is XORed with the polynomial A001 (1010 0000 0000 0001).
5. Repeat steps 3 and 4 until 8 times to the right, so that the entire 8-bit data has been processed.
6. Repeat steps 2 to 5 for the next 8-bit data processing.
7. The CRC register finally obtained is the CRC code.
8. When the CRC result is put into the information frame, the high and low bits are exchanged, and the low bit is first.

RS485 circuit

1. The installation position of the sensor can be selected on the ground, self-made big tube, iron pillar flange or on the roof of the house according to actual requirements.
2. Adjust the three leveling screws on the chassis to make the level bubble indication level (the bubble stays in the center of the circle), and then slowly tighten the three M8 × 80 fixing expansion screws; if the level bubble changes, you need to readjust.
3. Assemble and fix the sensor as shown in the figure above.
4. After fixing, open the rain bucket and cut off the nylon cable ties on the funnel, slowly inject fresh water into the rain sensor, and observe the turning process of the bucket to check whether the data is received on the acquisition instrument. Finally, quantitative water (60-70mm) is injected. If the data displayed by the acquisition instrument is consistent with the amount of injected water, the instrument is normal, otherwise it must be repaired and adjusted.
5. Avoid disassembling the sensor during installation.

1. Please check whether the packaging is intact and check whether the product model is consistent with the selection.
2. Do not connect line with power on. Only check the wiring and make sure the power is on.
3. The sensor cable length will affect the output signal of the product. Do not arbitrarily place the components or wires that have been soldered when the product leaves the factory. If there is a need for change, please contact the manufacturer.
4. The sensor should be inspected regularly to remove dust, mud, sand, leaves and insects, so as not to block the water flow channel of the upper tube (funnel). The cylindrical filter can be removed and washed with water.
5. There is dirt on the inner wall of the dump bucket, which can be washed with water or alcohol or detergent aqueous solution. It is strictly forbidden to wipe with fingers or other objects, so as not to get oily or scratch the inner wall of the dump bucket.
6. During freezing in winter, the instrument should be stopped and can be taken back to the room.
7. Please save the verification certificate and the certificate of conformity, and return it with the product when repairing.

1. The display meter has no indication. The collector may not be able to obtain the information correctly due to wiring problems. Please check whether the wiring is correct and firm.
2. The displayed value of the display is obviously inconsistent with the actual situation. Please empty the water bucket and refill the bucket with a certain amount of water (60-70mm), and clean the inside wall of the bucket.
3. If it is not the above reasons, please contact the manufacturer.

No Power supply Output Signal Instructions
LF-0004     Rain sensor
  5V-    
12V-    
24V-    
YV-    
  M Switch signal output
V 0-2.5V
V 0-5V
W2 RS485
A1 4-20mA
X Other
E.g.: LF-0014-5V-M: Rain sensor. 5V power supply, switch signal output

Product detail pictures:

Wholesale Price Soil Ph Sensor - Rain sensor stainless steel outdoor hydrological station – Huacheng detail pictures

Wholesale Price Soil Ph Sensor - Rain sensor stainless steel outdoor hydrological station – Huacheng detail pictures

Wholesale Price Soil Ph Sensor - Rain sensor stainless steel outdoor hydrological station – Huacheng detail pictures

Wholesale Price Soil Ph Sensor - Rain sensor stainless steel outdoor hydrological station – Huacheng detail pictures


Related Product Guide:

Our corporation puts emphasis about the administration, the introduction of talented staff, plus the construction of team building, attempting hard to improve the quality and liability consciousness of team members. Our organization successfully attained IS9001 Certification and European CE Certification of Wholesale Price Soil Ph Sensor - Rain sensor stainless steel outdoor hydrological station – Huacheng , The product will supply to all over the world, such as: United States, Islamabad, European, We've got sufficient experience in producing products according to samples or drawings. We warmly welcome customers from home and abroad to visit our company, and to cooperate with us for a splendid future together.
  • Adhering to the business principle of mutual benefits, we have a happy and successful transaction, we think we will be the best business partner.
    5 Stars By Faithe from Czech - 2018.07.27 12:26
    The after-sale warranty service is timely and thoughtful, encounter problems can be resolved very quickly, we feel reliable and secure.
    5 Stars By Alexander from Lahore - 2017.06.25 12:48
    Write your message here and send it to us

    Related products

    • One of Hottest for Atmospheric Dew Point - Microcomputer automatic calorimeter – Huacheng

      One of Hottest for Atmospheric Dew Point - Mic...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Newly Arrival  Ultrasonic Drum Level Sensor – PH Sensor – Huacheng

      Newly Arrival Ultrasonic Drum Level Sensor ...

      The new-generation PHTRSJ soil pH sensor solves the shortcomings of traditional soil pH that requires professional display instruments, tedious calibration, difficult integration, high power consumption, high price, and difficult to carry. ● New soil pH sensor, realizing online real-time monitoring of soil pH. ● It adopts the most advanced solid dielectric and large-area polytetrafluoroethylene liquid junction, which is not easy to block and maintenance-free. ● High integration, small size, l...

    • Professional China  Noise Meter - Microcomputer automatic calorimeter – Huacheng

      Professional China Noise Meter - Microcompute...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • High Quality for 3ml Plastic Transfer Pipettes - Microcomputer automatic calorimeter – Huacheng

      High Quality for 3ml Plastic Transfer Pipettes ...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • OEM Supply Transfer Pipet - Microcomputer automatic calorimeter – Huacheng

      OEM Supply Transfer Pipet - Microcomputer auto...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Hot-selling Industrial Combustible Gas Methane Alarm - Portable pump suction single gas detector User’s Manual – Huacheng

      Hot-selling Industrial Combustible Gas Methane ...

      System configuration 1. Table1 Material List of Portable pump suction single gas detector Gas Detector USB Charger Please check materials immediately after unpacking. The Standard is necessary accessories. The Optional can be chosen according to your needs. If you have no need to calibrate, set the alarm parameters, or read the alarm record, don’t purchase the optional accessories. System parameter Charging Time: about 3hours~6 hours Charging Voltage: DC5V Service Time: Combustible ...