This sensor is used to measure the spectral range of 0.3-3μm, solar radiation, can also be used to measure the incident solar radiation to the slant of the reflected radiation can be measured, such as the induction downwardly facing, light shielding ring measurable scattered radiation. Therefore, it can be widely applied to the use of solar energy, meteorology, agriculture, building materials, aging and atmospheric pollution and other departments to do the measurement of solar radiation energy.
Sensitivity | 7~14μV/w.m-2 |
Spectral range | 0.3-3μm |
Measuring range | 0 ~ 2000W/m2 |
Power supply | DC 5V |
DC 12V | |
DC 24V | |
Other | |
Output in the form | Pulse: Pulse signal |
Current: 4~20mA | |
Voltage: 0~2.5V | |
Voltage: 1~5V | |
Voltage: 0 ~ 20mV | |
RS232 | |
RS485 | |
Other | |
Instrument Line length | Standard: 2.5m |
Other | |
Response time | ≤ 35 seconds (99%) |
Internal resistance | approximately 350Ω |
Stability | ≤ ± 2% |
Cosine response | ≤7% (solar elevation angle of 10 °) |
Azimuth response error | ≤5% (solar elevation angle of 10 °) |
Temperature characteristics | ±2% (-10 ℃ to +40 ℃) |
Working ambient temperature | -40 ° C ~ +50 ° C |
Non-linear | ≤ 2% |
Weight | 2.5kg |
The sensor should be installed in the space, around the place above the sensing surface without any obstacles. Then the radiation table cable plug is on the north, adjust level position, firmly fixed, then the total radiation sensor output cable acquisition equipment connected to observation. The best cable is securely fixed to the mounting bracket to reduce the fracture or interruptions occur intermittently windy days.
Wiring instructions
Sensor name | Wiring color | Output Description | Corresponding plug pins |
TBQ Total radiation sensor | Red line | Positive signal output | Foot 1 of the four-pin plug |
Black line | Negative signal output | Foot 2 of the four-pin plug |
1. Serial format
8 data bits
1 stop bit
Parity None
Baud rate 9600 two communication interval of at least 1000ms
2. The communication format
[1] Is written to the device address
Send: 00 10 00 AA (16 hexadecimal data)
Description: 00 – Broadcast address (must be 0); 10 – Write operation (fixed); 00 – Address command (fixed); AA -Write the new address (only,1-255)
Returns: OK (OK return success)
[2] To read the device address
Sent: 000,300 (hexadecimal data)
Description: 00 – Broadcast address (must be 0); 03 – Read operation (fixed); 00 – Address command (fixed)
Returns: Address = XXX (ASCII code data, such as Address = 001, Address = 123, etc.)
Description: Address – address instructions; XXX – Address data, less than three integers, preceded by 0;
[1] Which units followed with a carriage return wrap data, two-byte hexadecimal data 0x0D 0x0A;
[2] The above description ignores transition spaces and ‘=’ character.
[3] Read real-time data
Send: AA 03 0F (16 decimal data)
Description: AA – Device address (only 1-255); 03 – Read operation (fixed); 0F – Data address (fixed)
Returns: The TBQ = XXXX W/m2 (ASCII code data, such as TBQ = 0400 W/m2 TBQ = 1000 W/m2 etc.)
Description: TBQ – TBQ total convergence of f our integers, preceded by 0; W/m2 – units
[1] Which units followed with a carriage return wrap data, two-byte hexadecimal data 0x0D 0x0A.
[2] The above description ignores transition spaces and ‘=’ character.
The sensor wires in the wiring method according to the instructions in the, and then placed in the position for the measurement of radiation, turn on the power and collection instrument switch, you can get the radiation value of the measurement points.
1. Please check the packaging is intact, and check whether the product model is consistent with the selection.
2. Do not live wiring, the wiring is complete check correct before electricity.
3. Do not tamper with the product factory welded components or wires.
4. The sensor is a precision device, use Do not disassemble, contact with the sensor surface with sharp objects or corrosive liquid, so as to avoid damage to the product.
5. Save the certificate and certificate maintenance together with product return.
1. When analog output, showing values significantly larger / smaller. Check the pass dirt or debris on the sensor sensing port; if so, with a dry net cloth to wipe away.
2. When analog output the display instrument represents a value of 0 or is not in range to within. May be due to wiring problems lead to acquisition instrument is unable to obtain the correct letter, please check the wiring is correct, firmly.
3. If the above reasons, please contact the manufacturer.
1. It is not allowed to demolition or loose filter mask, so as not to affect the measurement accuracy. Open or covered with a metal cover especially careful, because the filter mask precious and fragile. Filter mask to maintain smooth, often with a soft cloth or fur smear.
2. Filter mask should not has water, nor should be water vapor condensation hood. Desiccant desiccator should always check whether to change the tide (from blue to red or white), otherwise it must be promptly replaced or desiccant will get the oven to dry so that it changed back to blue again.
3. TBQ total radiation sensor waterproof performance is good, generally a short period of time or smaller precipitation cannot stamped. But the rainfall heavy rains (snow, ice, etc.) or a longer time, for the protection of the radiation table, observers is necessary, according to the specific circumstances of the best stamped, the rain stopped as soon as the cover is open.
4. TBQ total radiation sensor use for more than two years, re-calibration of its sensitivity by the manufacturer or metering department.
TBQ total radiation sensor from the factory on the date one year due to the non-human factors causing quality problems, the production unit is responsible for free repair or replacement. If the user man-made damage, will be charged the cost of fees, but does not charge maintenance fees. In addition, I solemnly promised to be responsible for products manufactured lifelong maintenance.
No. |
Power supply |
Export Signal |
Explain |
LF-0010 - |
|
|
TBQ total radiation sensor (Transmitter) |
|
5V- |
|
5VPower supply |
12V- |
|
12VPower supply |
|
24V- |
|
24VPower supply |
|
Z- |
|
No power |
|
|
V |
0-5V |
|
A1 |
4-20mA |
||
A2 |
0-20mA |
||
W1- |
RS232 |
||
W2- |
RS485 |
||
V3- |
0-20mV |
||
X- |
Other |
||
E.g.: LF-0010-12V-A: TBQ total radiation sensor 12V power supply, 4-20mA current signal output |
Product detail pictures:
Related Product Guide:
Our commission should be to provide our end users and clients with very best excellent and aggressive portable digital products and solutions for Top Suppliers Rain Water Sensor - LF-0010 TBQ Total Radiation Sensor – Huacheng , The product will supply to all over the world, such as: Germany, Comoros, Poland, With the technology as the core, develop and produce high-quality merchandise according to the diverse needs of the market. With this concept,the company will continue to develop merchandise with high added values and continuously improve items,and will present many customers with the best goods and services!
By Patricia from Estonia - 2017.06.22 12:49
In our cooperated wholesalers, this company has the best quality and reasonable price, they are our first choice.
By Jill from United States - 2017.05.02 11:33