We also supply merchandise sourcing and flight consolidation companies. We now have our very own manufacturing facility and sourcing business. We could present you with almost every kind of product relevant to our solution array for Wired Rain Sensor, Popular Univeral Pipette, Ultrasonic Multiparameter Sensor, Welcome worldwide customers to contact us for business and long-term cooperation. We will be your reliable partner and supplier of auto parts and accessories in China.
Special Design for Mass Air Flow Sensor Temperature - Soil temperature and humidity sensor soil transmitter – Huacheng Detail:

Measurement range soil moisture 0 ~ 100% soil temperature -20 ~ 50 ℃
Soil wet resolution 0.1%
Temperature resolution 0.1 ℃
Soil wet accuracy ± 3%
Temperature accuracy ± 0.5 ℃
Power supply mode DC 5V 
DC 12V 
DC 24V 
Other
Output form Current: 4~20mA 
Voltage: 0~2.5V 
Voltage: 0~5V    
RS232
RS485
TTL Level: (frequency; Pulse width)
Other
Load resistance Voltage type: RL≥1K
Current type: RL≤250Ω
Working temperature -50 ℃ ~ 80 ℃
Relative humidity 0 to 100%
Product weight 220 g probe with transmitter 570 g
Product power consumption about 420 mW

Soil humidity:
Voltage type (0 ~ 5V output):
R = V / 5 × 100%
(R is the soil moisture value and V is the output voltage value (V))
Current type (4 ~ 20mA output):
R = (I-4) / 16 × 100%
(R is the soil moisture value, I is the output current value (mA))

Soil temperature:
Voltage type (0 ~ 5V output):
T = V / 5 × 70-20
(T is the measured temperature value (℃), V is the output voltage value (V), this formula corresponds to the measurement range -20 ~ 50 ℃)
Current type (4 ~ 20mA)
T = (I-4) / 16 × 70 -20
(T is the measured temperature value (℃), I is the output current (mA), this formula corresponds to the measurement range -20 ~ 50 ℃)

1. If equipped with a weather station produced by the company, directly connect the sensor to the corresponding interface on the weather station using a sensor line;

2. If the transmitter is purchased separately, the corresponding line sequence of the transmitter is:

Line color Output signal
Voltage Current communication
Red Power + Power + Power +
Black(green) Power ground Power ground Power ground
Yellow Voltage signal Current signal A+/TX
Blue     B-/RX

Transmitter voltage and current output wiring:

Wiring for voltage output mode

Wiring for voltage output mode

Wiring for voltage output mode 1

Wiring for current output mode

Structure Dimensions

Structure Dimensions

Structure Dimensions 1

Sensor Size

1. The serial format
Data bits 8 bits
Stop bit 1 or 2
Check Digit None
Baud rate 9600 Communication interval is at least 1000ms
2. Communication format
[1] Write device address
Send: 00 10 Adress CRC (5 bytes)
Returns: 00 10 CRC (4 bytes)
Note: 1. The address bit of the read and write address command must be 00. 2. Adress is 1 byte and the range is 0-255.
Example: Send 00 10 01 BD C0
Returns 00 10 00 7C
[2] Read device address
Send: 00 20 CRC (4 bytes)
Returns: 00 20 Adress CRC (5 bytes)
Explanation: Adress is 1 byte, the range is 0-255
For example: Send 00 20 00 68
Returns 00 20 01 A9 C0
[3] Read real-time data
Send: Adress 03 00 00 00 02 XX XX
Note: as shown below

Code Function definition Note
Adress Station number (address)  
03 Function code  
00  00 Initial address  
00  02 Read points  
XX XX CRC Check code,front low later high  

Returns: Adress 03 04 XX XX XX XX YY YY
Note

Code Function definition Note
Adress Station number (address)  
03 Function code  
04 Read unit byte  
XX  XX Soil temperature data (high before, low after) Hex
XX  XX Soil humidity data (high before, low after) Hex
YY  YY CRCCheck code  

To calculate the CRC code:
1. The preset 16-bit register is FFFF in hexadecimal (that is, all are 1). Call this register the CRC register.
2. XOR the first 8-bit data with the lower bit of the 16-bit CRC register and put the result in the CRC register.
3. Shift the contents of the register to the right by one bit (toward the low bit), fill the highest bit with 0, and check the lowest bit.
4. If the least significant bit is 0: repeat step 3 (shift again), if the least significant bit is 1: the CRC register is XORed with the polynomial A001 (1010 0000 0000 0001).
5. Repeat steps 3 and 4 until 8 times to the right, so that the entire 8-bit data has been processed.
6. Repeat steps 2 to 5 for the next 8-bit data processing.
7. The CRC register finally obtained is the CRC code.
8. When the CRC result is put into the information frame, the high and low bits are exchanged, and the low bit is first.

Connect the sensor according to the instructions in the wiring method, then insert the probe pins of the sensor into the soil to measure humidity, and turn on the power and the collector switch to obtain the soil temperature and humidity at the measurement point.

1. Please check whether the packaging is intact and check whether the product model is consistent with the selection.
2. Do not connect with power on, and then power on after checking the wiring.
3. Do not arbitrarily change the components or wires that have been soldered when the product leaves the factory.
4. The sensor is a precision device. Please do not disassemble it by yourself or touch the surface of the sensor with sharp objects or corrosive liquids in order to avoid damaging the product.
5. Please keep the verification certificate and certificate of conformity, and return it with the product when repairing.

1. When the output is detected, the display indicates that the value is 0 or is out of range. Check whether there is obstruction from foreign objects. The collector may not be able to obtain the information correctly due to wiring problems. Please check whether the wiring is correct and firm;
2. If it is not the above reasons, please contact the manufacturer.

No Power supply Output Signal Instructions
LF-0008-     Soil temperature and humidity sensor
 
 
5V-   5V power supply
12V-   12V power supply
24V-   24V power supply
YV-   Other power
  V 0-5V
V2 0-2.5V
A1 4-20mA
W1 RS232
W2 RS485
TL TTL
M Pulse
X Other
E.g.:  LF-0008-12V-A1:Soil temperature and humidity sensor 12V power supply, 4-20mA current signal output

Product detail pictures:

Special Design for Mass Air Flow Sensor Temperature - Soil temperature and humidity sensor soil transmitter – Huacheng detail pictures

Special Design for Mass Air Flow Sensor Temperature - Soil temperature and humidity sensor soil transmitter – Huacheng detail pictures

Special Design for Mass Air Flow Sensor Temperature - Soil temperature and humidity sensor soil transmitter – Huacheng detail pictures

Special Design for Mass Air Flow Sensor Temperature - Soil temperature and humidity sensor soil transmitter – Huacheng detail pictures

Special Design for Mass Air Flow Sensor Temperature - Soil temperature and humidity sensor soil transmitter – Huacheng detail pictures

Special Design for Mass Air Flow Sensor Temperature - Soil temperature and humidity sensor soil transmitter – Huacheng detail pictures

Special Design for Mass Air Flow Sensor Temperature - Soil temperature and humidity sensor soil transmitter – Huacheng detail pictures


Related Product Guide:

Our company has been focusing on brand strategy. Customers' satisfaction is our best advertising. We also supply OEM service for Special Design for Mass Air Flow Sensor Temperature - Soil temperature and humidity sensor soil transmitter – Huacheng , The product will supply to all over the world, such as: Cairo, Dubai, Brasilia, We follow superior mechanism to process these products that ensure optimum durability and reliability of the products. We follow latest effective washing and straightening processes that allow us to offer unmatched quality of products for our clients. We continually strive for perfection and all our efforts are directed towards attaining complete client satisfaction.
  • Cooperate with you every time is very successful, very happy. Hope that we can have more cooperation!
    5 Stars By Alexander from Gabon - 2018.05.15 10:52
    As an international trading company, we have numerous partners, but about your company, I just want to say, you are really good, wide range, good quality, reasonable prices, warm and thoughtful service, advanced technology and equipment and workers have professional training, feedback and product update is timely, in short, this is a very pleasant cooperation, and we look forward to the next cooperation!
    5 Stars By Alexandra from Tunisia - 2017.05.21 12:31
    Write your message here and send it to us

    Related products

    • China Gold Supplier for Glass Separatory Funnel - Microcomputer automatic calorimeter – Huacheng

      China Gold Supplier for Glass Separatory Funnel...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • China Cheap price Portable Gas Detector - Portable gas sampling pump Operating instruction – Huacheng

      China Cheap price Portable Gas Detector - Port...

      ● Display: Large screen dot matrix liquid crystal display ● Resolution: 128*64 ● Language: English and Chinese ● Shell materials: ABS ● Working principle: Diaphragm self-priming ● Flow: 500mL/min ● Pressure: -60kPa ● Noise: <32dB ● working voltage: 3.7V ● Battery capacity: 2500mAh Li battery ● Stand-by time: 30hours(keep pumping open) ● Charging Voltage: DC5V ● Charging Time: 3~5 hours ● Working temperature: -10~50℃ ● Working Humidity: 10~95%RH(non-condensing) ● Dimension: 175*64*35(mm) Ex...

    • New Delivery for Portable Water Quality Analyzer - Microcomputer automatic calorimeter – Huacheng

      New Delivery for Portable Water Quality Analyze...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • High Quality Wind Direction Sensor - Rain sensor stainless steel outdoor hydrological station – Huacheng

      High Quality Wind Direction Sensor - Rain sens...

      Water-carrying caliber Ф200 ± 0.6mm Measuring range ≤4mm / min (precipitation intensity) Resolution 0.2mm (6.28ml) Accuracy ± 4% (indoor static test, rain intensity is 2mm / min) Power supply mode DC 5V  DC 12V  DC 24V  Other Output form Current 4 ~ 20mA Switching signal: On-off of reed switch Voltage: 0~2.5V  Voltage: 0~5V     Voltage 1 ~ 5V Other Instrument line length Standard: 5 meters Other Working temperature 0 ~ 50 ℃ Storage temperature -10 ℃ ~ ...

    • Super Lowest Price Rain Gauge Thermometer - Microcomputer automatic calorimeter – Huacheng

      Super Lowest Price Rain Gauge Thermometer - Mi...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Fast delivery Barometer Weather Station - Dust and Noise Monitoring Station – Huacheng

      Fast delivery Barometer Weather Station - Dust...

      The noise and dust monitoring system can carry out continuous automatic monitoring of monitoring points in the dust monitoring area of different sound and environmental functional areas. It is a monitoring device with complete functions. It can automatically monitor data in the case of unattended, and can automatically monitor data through GPRS/CDMA mobile public network and dedicated line. network, etc. to transmit data. It is an all-weather outdoor dust monitoring system developed by itself...