• Special Design for Mass Air Flow Sensor Temperature - Rain sensor stainless steel outdoor hydrological station – Huacheng

Special Design for Mass Air Flow Sensor Temperature - Rain sensor stainless steel outdoor hydrological station – Huacheng

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We strive for excellence, services the customers", hopes to be the top cooperation team and dominator business for personnel, suppliers and prospects, realizes benefit share and continual promotion for Port Weather Station, Centrifuge Tube Rack, Cod Analyzer, Our highly specialized process eliminates the component failure and offers our customers unvarying quality, allowing us to control cost, plan capacity and maintain consistent on time delivery.
Special Design for Mass Air Flow Sensor Temperature - Rain sensor stainless steel outdoor hydrological station – Huacheng Detail:

Water-carrying caliber Ф200 ± 0.6mm
Measuring range ≤4mm / min (precipitation intensity)
Resolution 0.2mm (6.28ml)
Accuracy ± 4% (indoor static test, rain intensity is 2mm / min)
Power supply mode DC 5V 
DC 12V 
DC 24V 
Other
Output form Current 4 ~ 20mA
Switching signal: On-off of reed switch
Voltage: 0~2.5V 
Voltage: 0~5V    
Voltage 1 ~ 5V
Other
Instrument line length Standard: 5 meters
Other
Working temperature 0 ~ 50 ℃
Storage temperature -10 ℃ ~ 50 ℃

1. If equipped with a weather station produced by the company, directly connect the sensor to the corresponding interface on the weather station using a sensor line;

2. If the sensor is purchased separately, as the sensor outputs a set of switching signals, the cable connector does not matter positive and negative. Connect the sensor to the circuit as shown in the figure.

lf-0004-rain

If the sensor outputs other signals, the corresponding line sequence and function of the conventional sensor are as follows:

Line color Output signal
Voltage Current communication
Red Power + Power + Power +
Black(green) Power ground Power ground Power ground
Yellow Voltage signal Current signal A+/TX
Blue     B-/RX

lf-0004-rain1

Structure Dimensions 

lf-0004-rain2

Transmitter size  

1. the serial format
Data bits 8 bits
Stop bit 1 or 2
Check Digit None
Baud rate 9600 Communication interval is at least 1000ms
2. Communication format
[1] Write device address
Send: 00 10 Adress CRC (5 bytes)
Returns: 00 10 CRC (4 bytes)
Note: 1. The address bit of the read and write address command must be 00.
2. Adress is 1 byte and the range is 0-255.
Example: Send 00 10 01 BD C0
Returns 00 10 00 7C
[2] Read device address
Send: 00 20 CRC (4 bytes)
Returns: 00 20 Adress CRC (5 bytes)
Explanation: Adress is 1 byte, the range is 0-255
For example: Send 00 20 00 68
Returns 00 20 01 A9 C0
[3] Read real-time data
Send: Adress 03 00 00 00 01 XX XX
Note: as shown below:

Code Function definition Note
Adress Station number (address)  
03 Function code  
00  00 Initial address  
00  01 Read points  
XX XX CRC Check code,front low later high  

Returns: Adress 03 02 XX XX XX XX YY YY
Note

Code Function definition Note
Adress Station number (address)  
03 Function code  
02 Read unit byte  
XX  XX Data (high before, low after) Hex
XX  XX CRCCheck code  

To calculate the CRC code:
1. The preset 16-bit register is FFFF in hexadecimal (that is, all are 1). Call this register the CRC register.
2. XOR the first 8-bit data with the lower bit of the 16-bit CRC register and put the result in the CRC register.
3. Shift the contents of the register to the right by one bit (toward the low bit), fill the highest bit with 0, and check the lowest bit。
4. If the least significant bit is 0: repeat step 3 (shift again), if the least significant bit is 1: the CRC register is XORed with the polynomial A001 (1010 0000 0000 0001).
5. Repeat steps 3 and 4 until 8 times to the right, so that the entire 8-bit data has been processed.
6. Repeat steps 2 to 5 for the next 8-bit data processing.
7. The CRC register finally obtained is the CRC code.
8. When the CRC result is put into the information frame, the high and low bits are exchanged, and the low bit is first.

RS485 circuit

1. The installation position of the sensor can be selected on the ground, self-made big tube, iron pillar flange or on the roof of the house according to actual requirements.
2. Adjust the three leveling screws on the chassis to make the level bubble indication level (the bubble stays in the center of the circle), and then slowly tighten the three M8 × 80 fixing expansion screws; if the level bubble changes, you need to readjust.
3. Assemble and fix the sensor as shown in the figure above.
4. After fixing, open the rain bucket and cut off the nylon cable ties on the funnel, slowly inject fresh water into the rain sensor, and observe the turning process of the bucket to check whether the data is received on the acquisition instrument. Finally, quantitative water (60-70mm) is injected. If the data displayed by the acquisition instrument is consistent with the amount of injected water, the instrument is normal, otherwise it must be repaired and adjusted.
5. Avoid disassembling the sensor during installation.

1. Please check whether the packaging is intact and check whether the product model is consistent with the selection.
2. Do not connect line with power on. Only check the wiring and make sure the power is on.
3. The sensor cable length will affect the output signal of the product. Do not arbitrarily place the components or wires that have been soldered when the product leaves the factory. If there is a need for change, please contact the manufacturer.
4. The sensor should be inspected regularly to remove dust, mud, sand, leaves and insects, so as not to block the water flow channel of the upper tube (funnel). The cylindrical filter can be removed and washed with water.
5. There is dirt on the inner wall of the dump bucket, which can be washed with water or alcohol or detergent aqueous solution. It is strictly forbidden to wipe with fingers or other objects, so as not to get oily or scratch the inner wall of the dump bucket.
6. During freezing in winter, the instrument should be stopped and can be taken back to the room.
7. Please save the verification certificate and the certificate of conformity, and return it with the product when repairing.

1. The display meter has no indication. The collector may not be able to obtain the information correctly due to wiring problems. Please check whether the wiring is correct and firm.
2. The displayed value of the display is obviously inconsistent with the actual situation. Please empty the water bucket and refill the bucket with a certain amount of water (60-70mm), and clean the inside wall of the bucket.
3. If it is not the above reasons, please contact the manufacturer.

No Power supply Output Signal Instructions
LF-0004     Rain sensor
  5V-    
12V-    
24V-    
YV-    
  M Switch signal output
V 0-2.5V
V 0-5V
W2 RS485
A1 4-20mA
X Other
E.g.: LF-0014-5V-M: Rain sensor. 5V power supply, switch signal output

Product detail pictures:

Special Design for Mass Air Flow Sensor Temperature - Rain sensor stainless steel outdoor hydrological station – Huacheng detail pictures

Special Design for Mass Air Flow Sensor Temperature - Rain sensor stainless steel outdoor hydrological station – Huacheng detail pictures

Special Design for Mass Air Flow Sensor Temperature - Rain sensor stainless steel outdoor hydrological station – Huacheng detail pictures

Special Design for Mass Air Flow Sensor Temperature - Rain sensor stainless steel outdoor hydrological station – Huacheng detail pictures


Related Product Guide:

To be a result of ours specialty and service consciousness, our company has won a superb reputation between customers all around the environment for Special Design for Mass Air Flow Sensor Temperature - Rain sensor stainless steel outdoor hydrological station – Huacheng , The product will supply to all over the world, such as: Doha, San Francisco, Malawi, We have been committed to meet all your needs and solve any technical problems you may encounter with your industrial components. Our exceptional products and vast knowledge of technology makes us the preferred choice for our customers.
  • Product variety is complete, good quality and inexpensive, the delivery is fast and transport is security, very good, we are happy to cooperate with a reputable company!
    5 Stars By Rosalind from Lesotho - 2018.09.29 17:23
    A nice supplier in this industry, after a detail and careful discussion, we reached a consensus agreement. Hope that we cooperate smoothly.
    5 Stars By Muriel from Irish - 2017.05.21 12:31
    Write your message here and send it to us

    Related products

    • Manufacturer for Soil Sensor - FXB-01 Metal wind vane wind direction sensor wind vane – Huacheng

      Manufacturer for Soil Sensor - FXB-01 Metal wi...

      Customized 3.5-meter-high luminous metal weather vane (customizable stainless steel pole of any height) Overall height: 350mm Pointer length: 1200mm Weight: 4.5kg Note: The support rod is configured by the customer

    • Factory made hot-sale Tube Rack - Microcomputer automatic calorimeter – Huacheng

      Factory made hot-sale Tube Rack - Microcompute...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Factory Price For Vehicle Outside Temperature Sensor - Soil temperature and humidity sensor soil transmitter – Huacheng

      Factory Price For Vehicle Outside Temperature S...

      Measurement range soil moisture 0 ~ 100% soil temperature -20 ~ 50 ℃ Soil wet resolution 0.1% Temperature resolution 0.1 ℃ Soil wet accuracy ± 3% Temperature accuracy ± 0.5 ℃ Power supply mode DC 5V  DC 12V  DC 24V  Other Output form Current: 4~20mA  Voltage: 0~2.5V  Voltage: 0~5V     RS232 RS485 TTL Level: (frequency; Pulse width) Other Load resistance Voltage type: RL≥1K Current type: RL≤250Ω Working temperature -50 ℃ ~ 80 ℃ Relative humidity 0 ...

    • Cheap PriceList for Wireless Rain Station - Microcomputer automatic calorimeter – Huacheng

      Cheap PriceList for Wireless Rain Station - Mi...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • OEM/ODM China Total Element Weather Station - Dust and Noise Monitoring Station – Huacheng

      OEM/ODM China Total Element Weather Station - ...

      The noise and dust monitoring system can carry out continuous automatic monitoring of monitoring points in the dust monitoring area of different sound and environmental functional areas. It is a monitoring device with complete functions. It can automatically monitor data in the case of unattended, and can automatically monitor data through GPRS/CDMA mobile public network and dedicated line. network, etc. to transmit data. It is an all-weather outdoor dust monitoring system developed by itself...

    • Cheap PriceList for Wireless Rain Station - Microcomputer automatic calorimeter – Huacheng

      Cheap PriceList for Wireless Rain Station - Mi...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...