Manufactur standard Ac Evaporator Temperature Sensor - Meteorological anemometer wind speed sensor – Huacheng
Manufactur standard Ac Evaporator Temperature Sensor - Meteorological anemometer wind speed sensor – Huacheng Detail:
Measurement range | 0~45m/s |
0~70m/s | |
Accuracy | ±(0.3+0.03V)m/s (V: wind speed) |
Resolution | 0.1m/s |
Staring wind speed | ≤0.5m/s |
Power supply mode | DC 5V |
DC 12V | |
DC 24V | |
Other | |
Out-put | Current: 4~20mA |
Voltage: 0~2.5V | |
Pulse:Pulse signal | |
Voltage: 0~5V | |
RS232 | |
RS485 | |
TTL Level: (frequency; Pulse width) | |
Other | |
Instrument Line length | Standard: 2.5m |
Other | |
Load capacity | Current mode impedance≤600Ω |
Voltage mode impedance≥1KΩ | |
Operating environment | Temperature: -40℃~50℃ |
Humidity: ≤100%RH | |
Defend grade | IP45 |
Cable grade | Nominal voltage:300V |
Temperature grade:80℃ | |
Produce weight | 130 g |
Power dissipation | 50 mW |
Impulsive:
W =0; (f = 0)
W =0.3+0.0877×f(f≠ 0)
(W: indicating value of wind speed(m/s); f: pulse signal frequency)
Current mode (4~20mA):
W = (i-4)×45/16
(W: indicating value of wind speed (m/s); i: current type(4-20mA))
Voltage type(0~5V):
W =V/5×45
(W: indicating value of wind speed(m/s) ; V: voltage signal(0-5V))
Voltage type(0~2.5V):
W =V/2.5×45
(W: indicating value of wind speed(m/s); V: voltage signal (0-2.5V)
There is five-core aviation plug, whose output is at the base of the sensor. The definition of each pin’s corresponding base pin.
1. If you have equipped with our company’s weather station, please attach the sensor cable to the appropriate connector on the weather station directly.
2. If you purchase the sensor separately, the order of the wires are as followed:
R(Red): power +
Y(Yellow): signal output
G(Green): power —
3. Two ways of wiring method of pulse voltage and current:
wiring method of voltage and current
output of current wiring method
Structure Dimensions
Wind speed Sensor
Base mounting dimensions
Dimensional drawing of base installation:
Installation aperture: 4mm
Distribution Diameter: 62.5mm
Interface Dimension: 15mm (suggest reserving 25mm for wiring)
Transmitter Size
1. Serial format
8 data bits
1 stop bit
Parity None
Baud rate 9600,Two communication interval of at least 1000ms
2. The communication format
[1] Is written to the device address
Send: 00 10 00 AA (16 hexadecimal data)
Description: 00 – broadcast address (must be 0); 10 – Write operation (fixed); 00 – Address command (fixed); AA – write the new address (only,1-255)
Returns: OK (OK return success)
[2] To read the device address
Sent: 00 03 00 (hexadecimal data)
Description: 00 – broadcast address (must be 0); 03 – Read operation (fixed); 00 – Address command (fixed)
Returns: Address = XXX (ASCII code data, such as Address = 001, Address = 123, etc.)
Description: Address – address instructions; XXX – address data, less than three integer preceded 0
[1] Which units followed with a carriage return wrap data, two-byte hexadecimal data 0x0D 0x0A;
[2] The above description ignores transition spaces and ‘=’ character.
[3] Read real-time data
Send: AA 03 0F (16 decimal data)
Description: AA – Device address (only 1-255); 03 – read operation (fixed); 0F – data address (fixed)
Back: WS = XX.Xm/s (ASCII code data, such as WS =12.3m/s, WS = 00.5m/s)
Description: WS – Wind speed; XX.X – wind speed data, bring a decimal less than two integers, the leading zeros m/s – units
[1] Which units followed with a carriage return wrap data, two-byte hexadecimal data 0x0D 0x0A;
[2] The above description ignores transition spaces and ‘=’ character.
1. Please examine whether the package is intact or not please, and check whether the product is consistent with your selected type.
2. Be sure no power is applied before you ensure the wiring connection is errorless.
3. No alteration to factory-set components or cables.
4. Sensor is an accurate instrument. Do not separate, damage the interface of the sensor with sharp solid and corrosive liquid.
5. Please save the verification certification and Certificate of approval which may return to repair with the products.
1. If anemometer bearing is not rotating well or have a big delay. It may because the long-term use lead to foreign matters in the bearings or weather there is any remained lubricating oil. Please inject the oil from the upside of bearings or post the sensors to our company to oiling.
2. If the indicated value is 0 or out of range when use analog output. It may be cause by cable connections. Please check weather the cable connections are correct and fastness.
3. If not the above reasons, please contact with us.
No | Power supply | Output Signal | Instructions |
LF-0001 | wind speed sensors (transmitters) | ||
5V- | 5Vpower supply | ||
12V- | 12Vpower supply | ||
24V- | 24Vpower supply | ||
YV- | Other power supply | ||
V | 0-5V | ||
V1 | 1-5V | ||
V2 | 0-2.5V | ||
A1 | 4-20mA | ||
A2 | 0-20mA | ||
W1 | RS232 | ||
W2 | RS485 | ||
TL | TTL | ||
M | pulse | ||
X | other | ||
E.g. LF-0001-5V-M: wind speed sensors(transmitters)5Vpower supply, output of pulse |
Scale | Description | Land conditions | Wind speed m/s |
0 | Calm | Calm. Smoke rises vertically. | 0~0.2 |
1 | Light air | Smoke drift indicates wind direction, still wind vanes. | 0.3~1.5 |
2 | Light breeze | Wind felt on exposed skin. Leaves rustle, vanes begin to move. | 1.6~3.3 |
3 | Gentle breeze | Leaves and small twigs constantly moving, light flags extended. | 3.4~5.4 |
4 | Moderate | Dust and loose paper raised. Small branches begin to move. | 5.5~7.9 |
5 | Fresh breeze | Branches of a moderate size move. Small trees in leaf begin to sway. | 8.0~10.7 |
6 | Strong breeze | Large branches in motion. Whistling heard in overhead wires. Umbrella use becomes difficult. Empty plastic garbage cans tip over. | 10.8~13.8 |
7 | Moderate gale | Whole trees in motion. Effort needed to walk against the wind. | 13.9~17.l |
8 | Gale | Some twigs broken from trees. Cars veer on road. Progress on foot is seriously impeded. | 17.2~20.7 |
9 | Strong gale | Some branches break off trees, and some small trees blow over. Construction/temporary signs and barricades blow over. | 20.8~24.4 |
10 | Storm | Trees are broken off or uprooted, saplings bent and deformed. Poorly attached asphalt shingles and shingles in poor condition peel off roofs. | 24.5~28.4 |
11 | Violent storm | Widespread damage to vegetation. Many roofing surfaces are damaged; asphalt tiles that have curled up and/or fractured due to age may break away completely. | 28.5~32.6 |
12 | Hurricane-force | Very widespread damage to vegetation. Some windows may break; mobile homes and poorly constructed sheds and barns are damaged. Debris may be hurled about. | >32.6 |
Product detail pictures:
Related Product Guide:
It can be a great way to enhance our solutions and service. Our mission would be to build inventive products to consumers with a superior working experience for Manufactur standard Ac Evaporator Temperature Sensor - Meteorological anemometer wind speed sensor – Huacheng , The product will supply to all over the world, such as: Guyana, Montpellier, Gabon, Adhering to the principle of "Enterprising and Truth-Seeking, Preciseness and Unity", with technology as the core, our company continues to innovate, dedicated to providing you with the highest cost-effective products and meticulous after-sales service. We firmly believe that: we are outstanding as we are specialized.