We emphasize advancement and introduce new products into the market each year for Thermometer To Measure Air Temperature, Portable Doppler Flow Meter, 3ml Plastic Transfer Pipettes, We are sincerely looking forward to establishing good cooperative relationships with customers from at home and abroad for creating a bright future together.
Manufactur standard Ac Evaporator Temperature Sensor - LF-0020 water temperature sensor – Huacheng Detail:

Measurement range -50~100℃
-20~50℃
Accuracy ±0.5℃
Power supply DC 2.5V 
DC 5V 
DC 12V 
DC 24V 
Other
Out-put Current: 4~20mA 
Voltage: 0~2.5V 
Voltage: 0~5V    
RS232
RS485
TTL Level: (frequency; Pulse width)
Other
Line length Standard: 10 meters
Other  
Load capacity Current output impedance≤300Ω
Voltage output impedance≥1KΩ
Operating environment Temperature: -50℃~80℃
Humidity: ≤100%RH    
Produce weight Probe 145 g, with collector 550 g
Power dissipation 0.5 mW

Voltage type (0~5V):
T=V / 5 × 70 -20
(T is the measured temperature value (℃), V is the output voltage (V), this formula corresponds to the measurement range -20 ~ 50 ℃)
T=V / 5 × 150 -50
(T is the measured temperature value (℃), V is the output voltage (V), this formula corresponds to the measurement range -50 ~ 100 ℃)
Current type (4~20mA)
T=(I-4)/ 16 × 70 -20
(T is the measurement temperature value (℃), I is the output current (mA), this type corresponds to the measurement range -20 ~ 50 ℃)
T=(I-4)/ 16 × 150 -50
(T is the measured temperature value (℃), I is the output current (mA), this formula corresponds to the measurement range -50 ~ 100 ℃)
Note: The calculation formulas corresponding to different signal outputs and different measurement ranges need to be recalculated!

1. If equipped with a weather station produced by our company, directly connect the sensor to the corresponding interface on the weather station using the sensor cable.
2. If the transmitter is purchased separately, the matching cable sequence of the transmitter is:

Line color

Output signal

Voltage type

Current type

Communication type

Red

Power+

Power+

Power+

Black (green)

Power ground

Power ground

Power ground

Yellow

Voltage signal

Current signal

A+/TX

Blue

 

 

B-/RX

3. Transmitter voltage and current output wiring:

LF-0020 water temperature sensor5

Wiring for voltage output mode 

LF-0020 water temperature sensor6

Wiring for current output mode

LF-0020 water temperature sensor7

(Water temperature sensor)

LF-0020 water temperature sensor8

(Water temperature sensor)

1. The serial format
Data bits 8 bits
Stop bit 1 or 2
Check Digit None
Baud rate 9600 Communication interval is at least 1000ms
2. Communication format
[1] Write device address
Send: 00 10 Adress CRC (5 bytes)
Returns: 00 10 CRC (4 bytes)
Note: 1. The address bit of the read and write address command must be 00.
2. Adress is 1 byte and the range is 0-255.
Example: Send 00 10 01 BD C0
Returns 00 10 00 7C
[2] Read device address
Send: 00 20 CRC (4 bytes)
Returns: 00 20 Adress CRC (5 bytes)
Explanation: Adress is 1 byte, the range is 0-255
For example: Send 00 20 00 68
Returns 00 20 01 A9 C0
[3] Read real-time data
Send: Adress 03 00 00 00 02 XX XX
Note: as shown below:

Code

Function definition

Note

Adress

Station number (address)

 

03

Function code

 

00  00

Initial address

 

00  01

Read points

 

XX XX

CRC Check code,front low later high

 

Returns: Adress 03 02 XX XX XX XX

Code

Function definition

Note

Adress

Station number (address)

 

03

Function code

 

02

Read unit byte

 

XX  XX

Soil temperature data (high before, low after)

Hex

XX  XX

Soil humidity data (high before, low after)

 

To calculate the CRC code:
1. The preset 16-bit register is FFFF in hexadecimal (that is, all are 1). Call this register the CRC register.
2. XOR the first 8-bit data with the lower bit of the 16-bit CRC register and put the result in the CRC register.
3. Shift the contents of the register to the right by one bit (toward the low bit), fill the highest bit with 0, and check the lowest bit.
4. If the least significant bit is 0: repeat step 3 (shift again), if the least significant bit is 1: the CRC register is XORed with the polynomial A001 (1010 0000 0000 0001).
5. Repeat steps 3 and 4 until 8 times to the right, so that the entire 8-bit data has been processed.
6. Repeat steps 2 to 5 for the next 8-bit data processing.
7. The CRC register finally obtained is the CRC code.
8. When the CRC result is put into the information frame, the high and low bits are exchanged, and the low bit is first.

LF-0020 water temperature sensor9

Connect the sensor according to the instructions in the wiring method, and then insert the sensor probe into the soil to measure the temperature, and supply power to the collector and the sensor to obtain the water temperature at the measurement point.  

1. Please check whether the packaging is intact and check whether the product model is consistent with the selection.
2. Do not connect with power on, and then power on after checking the wiring.
3. Do not arbitrarily change the components or wires that have been soldered when the product leaves the factory.
4. The sensor is a precision device. Please do not disassemble it by yourself or touch the surface of the sensor with sharp objects or corrosive liquids in order to avoid damaging the product.
5. Please keep the verification certificate and certificate of conformity, and return it with the product when repairing.

1. When the output is detected, the display indicates that the value is 0 or is out of range. Check whether there is obstruction from foreign objects. The collector may not be able to obtain the information correctly due to wiring problems. Please check whether the wiring is correct and firm.
2. If it is not the above reasons, please contact the manufacturer.

Number

Power supply mode

Output signal

Explain

LF-0020

 

 

Water temperature sensor

 

5V-

 

5V powered

12V-

 

12V powered

24V-

 

24V powered

YV-

 

Other powered

 

0

No change

V

0-5V

V1

1-5V

V2

0-2.5V

A1

4-20mA

A2

0-20mA

W1

RS232

W2

RS485

TL

TTL

M

Pulse

X

Other

For example: LF-0020-24V-A1: water temperature sensor (transmitter)

24V power supply, 4-20mA output


Product detail pictures:

Manufactur standard Ac Evaporator Temperature Sensor - LF-0020 water temperature sensor – Huacheng detail pictures

Manufactur standard Ac Evaporator Temperature Sensor - LF-0020 water temperature sensor – Huacheng detail pictures

Manufactur standard Ac Evaporator Temperature Sensor - LF-0020 water temperature sensor – Huacheng detail pictures

Manufactur standard Ac Evaporator Temperature Sensor - LF-0020 water temperature sensor – Huacheng detail pictures

Manufactur standard Ac Evaporator Temperature Sensor - LF-0020 water temperature sensor – Huacheng detail pictures


Related Product Guide:

To consistently enhance the management method by virtue of the rule of "sincerely, fantastic religion and top quality are the base of business development", we extensively absorb the essence of associated goods internationally, and constantly acquire new merchandise to satisfy the needs of shoppers for Manufactur standard Ac Evaporator Temperature Sensor - LF-0020 water temperature sensor – Huacheng , The product will supply to all over the world, such as: belarus, Holland, Mexico, The best and original quality for spare parts is a most important factor for transportation. We may stick on supplying original and good quality parts even a little profit earned. God will bless us to do kindness business forever.
  • Cooperate with you every time is very successful, very happy. Hope that we can have more cooperation!
    5 Stars By Moira from Somalia - 2017.10.27 12:12
    The supplier abide the theory of "quality the basic, trust the first and management the advanced" so that they can ensure a reliable product quality and stable customers.
    5 Stars By Bess from Bulgaria - 2018.06.18 19:26
    Write your message here and send it to us

    Related products

    • China OEM Super Wave Cleaning Machine - Microcomputer automatic calorimeter – Huacheng

      China OEM Super Wave Cleaning Machine - Microc...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Europe style for 8 Channel Pipette - Microcomputer automatic calorimeter – Huacheng

      Europe style for 8 Channel Pipette - Microcomp...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Hot-selling Sound Level Tester - CLEAN MD110 Ultra-thin Digital Magnetic Stirrer – Huacheng

      Hot-selling Sound Level Tester - CLEAN MD110 U...

      ●60-2000 rpm (500ml H2O) ●LCD screen displays working and setting status ●11mm ultra-thin body, stable and space-saving ●Quiet, no loss, no maintenance ●Clockwise and counterclockwise (automatic) switching ●Off timer setting ●Compliant with CE specifications and does not interfere with electrochemical measurements ●Use environment 0-50°C Rated Voltage 100 – 240VC Rated frequency 50-6Hz Output voltage 12VDC Input power 5W Magnetic Stirrer Quadrupole Drive Coil Display LCD ...

    • OEM Manufacturer Outside Air Temperature Sensor - LF-0010 TBQ Total Radiation Sensor – Huacheng

      OEM Manufacturer Outside Air Temperature Sensor...

      This sensor is used to measure the spectral range of 0.3-3μm, solar radiation, can also be used to measure the incident solar radiation to the slant of the reflected radiation can be measured, such as the induction downwardly facing, light shielding ring measurable scattered radiation. Therefore, it can be widely applied to the use of solar energy, meteorology, agriculture, building materials, aging and atmospheric pollution and other departments to do the measurement of solar radiation energ...

    • Chinese Professional Lab Metalware - Microcomputer automatic calorimeter – Huacheng

      Chinese Professional Lab Metalware - Microcomp...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Cheap price Portable Gas Concentration Detector - Single Gas Detector User’s manual – Huacheng

      Cheap price Portable Gas Concentration Detector...

      For security reasons, the device only by suitably qualified personnel operation and maintenance. Prior to the operation or maintenance, please read and fully manage all solutions to these instructions. Including operations, maintenance of equipment and process methods. And a very important safety precautions. Read the following Cautions before using the detector. Table 1 Cautions Cautions 1. Warning: Unauthorized replacement of replacement parts in order to avoid the impact of the instru...