We believe that prolonged time period partnership is really a result of top of the range, benefit added provider, prosperous knowledge and personal contact for Rain Gauge With Ground Stake, Beaker Glass Laboratory Glassware, Plastic Test Tube Rack, Thanks for taking your worthwhile time to go to us and stay up for have a nice cooperation along with you.
Low price for Weather Sensor - LF-0010 TBQ Total Radiation Sensor – Huacheng Detail:

This sensor is used to measure the spectral range of 0.3-3μm, solar radiation, can also be used to measure the incident solar radiation to the slant of the reflected radiation can be measured, such as the induction downwardly facing, light shielding ring measurable scattered radiation. Therefore, it can be widely applied to the use of solar energy, meteorology, agriculture, building materials, aging and atmospheric pollution and other departments to do the measurement of solar radiation energy.

Sensitivity 7~14μV/w.m-2
Spectral range 0.3-3μm
Measuring range 0 ~ 2000W/m2
Power supply DC 5V 
DC 12V 
DC 24V 
Other
Output in the form Pulse: Pulse signal
Current: 4~20mA  
Voltage: 0~2.5V 
Voltage: 1~5V    
Voltage: 0 ~ 20mV
RS232
RS485
Other
Instrument Line length Standard: 2.5m
Other  
Response time ≤ 35 seconds (99%)
Internal resistance approximately 350Ω
Stability ≤ ± 2%
Cosine response ≤7% (solar elevation angle of 10 °)
Azimuth response error ≤5% (solar elevation angle of 10 °)
Temperature characteristics ±2% (-10 ℃ to +40 ℃)
Working ambient temperature -40 ° C ~ +50 ° C
Non-linear ≤ 2%
Weight 2.5kg

LF-0010 TBQ Total Radiation Sensor5
LF-0010 TBQ Total Radiation Sensor4
LF-0010 TBQ Total Radiation Sensor6

The sensor should be installed in the space, around the place above the sensing surface without any obstacles. Then the radiation table cable plug is on the north, adjust level position, firmly fixed, then the total radiation sensor output cable acquisition equipment connected to observation. The best cable is securely fixed to the mounting bracket to reduce the fracture or interruptions occur intermittently windy days.

Wiring instructions

Sensor name Wiring color Output Description Corresponding plug pins
TBQ Total radiation sensor Red line Positive signal output Foot 1 of the four-pin plug
Black line Negative signal output Foot 2 of the four-pin plug

1. Serial format
8 data bits
1 stop bit
Parity None
Baud rate 9600 two communication interval of at least 1000ms
2. The communication format
[1] Is written to the device address
Send: 00 10 00 AA (16 hexadecimal data)
Description: 00 – Broadcast address (must be 0); 10 – Write operation (fixed); 00 – Address command (fixed); AA -Write the new address (only,1-255)
Returns: OK (OK return success)
[2] To read the device address
Sent: 000,300 (hexadecimal data)
Description: 00 – Broadcast address (must be 0); 03 – Read operation (fixed);  00 – Address command (fixed)
Returns: Address = XXX (ASCII code data, such as Address = 001, Address = 123, etc.)
Description: Address – address instructions; XXX – Address data, less than three integers, preceded by 0;
[1] Which units followed with a carriage return wrap data, two-byte hexadecimal data 0x0D 0x0A;
[2] The above description ignores transition spaces and ‘=’ character.
[3] Read real-time data
Send: AA 03 0F (16 decimal data)
Description: AA – Device address (only 1-255); 03 – Read operation (fixed); 0F – Data address (fixed)
Returns: The TBQ = XXXX W/m2 (ASCII code data, such as TBQ = 0400 W/m2 TBQ = 1000 W/m2 etc.)
Description: TBQ – TBQ total convergence of f our integers, preceded by 0; W/m2 – units
[1] Which units followed with a carriage return wrap data, two-byte hexadecimal data 0x0D 0x0A.
[2] The above description ignores transition spaces and ‘=’ character.

The sensor wires in the wiring method according to the instructions in the, and then placed in the position for the measurement of radiation, turn on the power and collection instrument switch, you can get the radiation value of the measurement points.

1. Please check the packaging is intact, and check whether the product model is consistent with the selection.
2. Do not live wiring, the wiring is complete check correct before electricity.
3. Do not tamper with the product factory welded components or wires.
4. The sensor is a precision device, use Do not disassemble, contact with the sensor surface with sharp objects or corrosive liquid, so as to avoid damage to the product.
5. Save the certificate and certificate maintenance together with product return.

1. When analog output, showing values ​​significantly larger / smaller. Check the pass dirt or debris on the sensor sensing port; if so, with a dry net cloth to wipe away.
2. When analog output the display instrument represents a value of 0 or is not in range to within. May be due to wiring problems lead to acquisition instrument is unable to obtain the correct letter, please check the wiring is correct, firmly.
3. If the above reasons, please contact the manufacturer.

1. It is not allowed to demolition or loose filter mask, so as not to affect the measurement accuracy. Open or covered with a metal cover especially careful, because the filter mask precious and fragile. Filter mask to maintain smooth, often with a soft cloth or fur smear.
2. Filter mask should not has water, nor should be water vapor condensation hood. Desiccant desiccator should always check whether to change the tide (from blue to red or white), otherwise it must be promptly replaced or desiccant will get the oven to dry so that it changed back to blue again.
3. TBQ total radiation sensor waterproof performance is good, generally a short period of time or smaller precipitation cannot stamped. But the rainfall heavy rains (snow, ice, etc.) or a longer time, for the protection of the radiation table, observers is necessary, according to the specific circumstances of the best stamped, the rain stopped as soon as the cover is open.
4. TBQ total radiation sensor use for more than two years, re-calibration of its sensitivity by the manufacturer or metering department.

TBQ total radiation sensor from the factory on the date one year due to the non-human factors causing quality problems, the production unit is responsible for free repair or replacement. If the user man-made damage, will be charged the cost of fees, but does not charge maintenance fees. In addition, I solemnly promised to be responsible for products manufactured lifelong maintenance.

No.

Power supply

Export

Signal

Explain

LF-0010 -

 

 

TBQ total radiation sensor

(Transmitter)

 

5V-

 

5VPower supply

12V-

 

12VPower supply

24V-

 

24VPower supply

Z-

 

No power

 

V

0-5V

A1

4-20mA

A2

0-20mA

W1-

RS232

W2-

RS485

V3-

0-20mV

X-

Other

E.g.: LF-0010-12V-A: TBQ total radiation sensor 12V power supply, 4-20mA current signal output


Product detail pictures:

Low price for Weather Sensor - LF-0010 TBQ Total Radiation Sensor – Huacheng detail pictures

Low price for Weather Sensor - LF-0010 TBQ Total Radiation Sensor – Huacheng detail pictures

Low price for Weather Sensor - LF-0010 TBQ Total Radiation Sensor – Huacheng detail pictures

Low price for Weather Sensor - LF-0010 TBQ Total Radiation Sensor – Huacheng detail pictures


Related Product Guide:

We have a professional, efficiency team to provide quality service for our customer. We always follow the tenet of customer-oriented, details-focused for Low price for Weather Sensor - LF-0010 TBQ Total Radiation Sensor – Huacheng , The product will supply to all over the world, such as: Salt Lake City, Chile, United Arab emirates, Our stock have valued 8 million dollar , you can find the competitive parts within short delivery time. Our company is not only your partner in business, but also our company is your assistant in the coming corporation.
  • The sales person is professional and responsible, warm and polite, we had a pleasant conversation and no language barriers on communication.
    5 Stars By Elizabeth from Accra - 2018.06.12 16:22
    Perfect services, quality products and competitive prices, we have work many times, every time is delighted, wish continue to maintain!
    5 Stars By Helen from Philippines - 2017.09.30 16:36
    Write your message here and send it to us

    Related products

    • 2022 wholesale price  Portable Steam Flow Meter - Microcomputer automatic calorimeter – Huacheng

      2022 wholesale price Portable Steam Flow Meter...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • factory Outlets for Portable Water Quality Multi-Parameter Analyzer - Microcomputer automatic calorimeter – Huacheng

      factory Outlets for Portable Water Quality Mult...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • 8 Year Exporter Anemometer - Microcomputer automatic calorimeter – Huacheng

      8 Year Exporter Anemometer - Microcomputer aut...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • China OEM Pipettes - Microcomputer automatic calorimeter – Huacheng

      China OEM Pipettes - Microcomputer automatic c...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • New Arrival China Centrifuge Tube - Microcomputer automatic calorimeter – Huacheng

      New Arrival China Centrifuge Tube - Microcompu...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Trending Products  Glass Dropper Bottle - Microcomputer automatic calorimeter – Huacheng

      Trending Products Glass Dropper Bottle - Micr...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...