• Low MOQ for Volume Transfer Pipette - Microcomputer automatic calorimeter – Huacheng

Low MOQ for Volume Transfer Pipette - Microcomputer automatic calorimeter – Huacheng

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

The company upholds the philosophy of "Be No.1 in quality, be rooted on credit and trustworthiness for growth", will continue to serve old and new customers from home and overseas whole-heatedly for Laboratory Test Tubes Stand, Water Quality Cod Rapid Analyzer, Laboratory Water Quality Meter, In case you pursuit the Hi-quality, Hi-stable, Aggressive price elements, corporation name is your greatest choice!
Low MOQ for Volume Transfer Pipette - Microcomputer automatic calorimeter – Huacheng Detail:

Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials.

In line with GB/T213-2008 “Coal thermal determination Method”

GB/T384 “Determination of calorific value of petroleum products”

JC/T1005-2006 “Cement black raw material calorific value determination method”

ASTM D5865-2010 “Test Method for Total Calorific Value of Coal and Coking Coal”

GB/T30727-2014 “Solid biomass fuel calorific value determination method”

ISO 1928-2009 “Solid mineral Fuels – Determination of Total Value and Calculation of Net Calorific Value by bomb Calorimeter” requirements.

● It is mainly composed of constant temperature calorimetry system and single-chip microcomputer control system. It is a highly automatic heat measuring instrument controlled by single-chip microcomputer system and capable of data processing.

● The instrument is mainly used for coal, petroleum, chemical, food, wood and other combustible material calorific value measurement, in the measurement of the barrel calorific value at the same time conversion of the corresponding high calorific value and low calorific value.

Adopt American technology touch type LCD screen, integral installation method, ensure the firmness of touch screen.

Infrared technology, CRT display material to make the touch screen more durable. Multi-layer composite film cover, ensure color distortion, reflection and clarity to achieve the best state, sensitive induction, high positioning accuracy, effective infested area up to 90% wear resistance, life can be up to 10 years.

Chinese characters display, without external computer, can be operated directly. Can store more than 1000 data, display heating curve.

Adopt advanced single chip microcomputer system, the operation is fully automatic, the manual need to do is weighing, loading and oxygen, the instrument automatically complete quantitative water injection, automatic mixing, ignition, output printing results, drainage and other work.

Reasonable structure, reliable performance, low failure rate. The results are accurate and the unique cooling correction system ensures the stability of the instrument performance for a long time.

● Controlled by microcomputer, can provide reports of coal quality, man-machine interaction, namely learning. Automatic water injection, drainage, no need to adjust the water temperature, just install the oxygen bomb into the barrel, the instrument will automatically complete all the testing work.

● Accurate structure, unique cooling correction system, to ensure long-term stability of instrument performance. Electronic refrigeration process, completely not affected by environmental temperature changes, to ensure that the temperature difference between the inside and outside of the instrument meets the requirements of the national standard. Can work continuously for a long time.

● Fast test speed, test period ≤8min(rapid method) ≤15min, repeatability and reproducibility of calorific value test in line with GB/T384 “Determination of calorific value of Petroleum Products” standard, GB/T213-2008 “Coal calorific value determination Method” requirements.

The product provides excellent performance and reliability even in harsh environments.

● High degree of automation, automatic use of built-in fixed container bucket water, automatic control of the temperature difference between the inside and outside of the instrument bucket, automatic completion of the whole process of the test.

Rich data processing functions, users can easily query historical test data, data of the day, parallel sample data, etc.
Three, technical parameters:

Heat capacity about 10500 J/K
Temperature range 0~60 ℃
Oxygen bomb capacity 300ml
Response time < 4 S
Oxygen pressure 2.8~3.2 MPa
Resolution 0.0001 ℃
Pressure performance water pressure 20MPa
Linearity <0.08% within the range of temperature rise every 5℃
Weight 25 Kg
Temperature measurement error accuracy ±0.003℃ for every 5℃ temperature rise range
Dimensions 660mm×500mm×500mm
Supply voltage AC220V±10%
Humidity 80% or less
Power 30 w
Ignition voltage AC24V
Ignition time 5S

Product detail pictures:

Low MOQ for Volume Transfer Pipette - Microcomputer automatic calorimeter – Huacheng detail pictures


Related Product Guide:

Fast and very good quotations, informed advisers to help you choose the correct merchandise that suits all your preferences, a short creation time, responsible excellent command and different companies for paying and shipping affairs for Low MOQ for Volume Transfer Pipette - Microcomputer automatic calorimeter – Huacheng , The product will supply to all over the world, such as: Hanover, Lahore, Uzbekistan, Adhering to the management tenet of "Managing Sincerely, Winning by Quality", we try our best to provide excellent products and service to our clients. We look forward to making progress together with domestic and international clients.
  • Product variety is complete, good quality and inexpensive, the delivery is fast and transport is security, very good, we are happy to cooperate with a reputable company!
    5 Stars By Joseph from New Orleans - 2018.11.28 16:25
    This supplier's raw material quality is stable and reliable, has always been in accordance with the requirements of our company to provide the goods that quality meet our requirements.
    5 Stars By Eileen from Netherlands - 2017.05.21 12:31
    Write your message here and send it to us

    Related products

    • PriceList for Four In One Gas Alarm - Single-point Wall-mounted Gas Alarm Instruction Manual (Carbon dioxide) – Huacheng

      PriceList for Four In One Gas Alarm - Single-p...

      ● Sensor: infrared sensor ● Responding time: ≤40s (conventional type) ● Work pattern: continuous operation, high and low alarm point(could be set) ● Analog interface: 4-20mA signal output [option] ● Digital interface: RS485-bus interface [option] ● Display mode: Graphic LCD ● Alarming mode: Audible alarm — above 90dB; Light alarm — High intensity strobes ● Output control: relay output with two way alarming control ● Additional function: time display, calendar display ● Storage: 30...

    • Special Price for Temperature And Humidity Sensor Outdoor - LF-0020 water temperature sensor – Huacheng

      Special Price for Temperature And Humidity Sens...

      Measurement range -50~100℃ -20~50℃ Accuracy ±0.5℃ Power supply DC 2.5V  DC 5V  DC 12V  DC 24V  Other Out-put Current: 4~20mA  Voltage: 0~2.5V  Voltage: 0~5V     RS232 RS485 TTL Level: (frequency; Pulse width) Other Line length Standard: 10 meters Other   Load capacity Current output impedance≤300Ω Voltage output impedance≥1KΩ Operating environment Temperature: -50℃~80℃ Humidity: ≤100%RH     Produce weight Probe 145 g, with collector 550 g P...

    • Best Price on  Air Pressure Sensor Module - Rain sensor stainless steel outdoor hydrological station – Huacheng

      Best Price on Air Pressure Sensor Module - Ra...

      Water-carrying caliber Ф200 ± 0.6mm Measuring range ≤4mm / min (precipitation intensity) Resolution 0.2mm (6.28ml) Accuracy ± 4% (indoor static test, rain intensity is 2mm / min) Power supply mode DC 5V  DC 12V  DC 24V  Other Output form Current 4 ~ 20mA Switching signal: On-off of reed switch Voltage: 0~2.5V  Voltage: 0~5V     Voltage 1 ~ 5V Other Instrument line length Standard: 5 meters Other Working temperature 0 ~ 50 ℃ Storage temperature -10 ℃ ~ ...

    • Excellent quality Leaf Temperature And Humidity Sensor - Rain sensor stainless steel outdoor hydrological station – Huacheng

      Excellent quality Leaf Temperature And Humidity...

      Water-carrying caliber Ф200 ± 0.6mm Measuring range ≤4mm / min (precipitation intensity) Resolution 0.2mm (6.28ml) Accuracy ± 4% (indoor static test, rain intensity is 2mm / min) Power supply mode DC 5V  DC 12V  DC 24V  Other Output form Current 4 ~ 20mA Switching signal: On-off of reed switch Voltage: 0~2.5V  Voltage: 0~5V     Voltage 1 ~ 5V Other Instrument line length Standard: 5 meters Other Working temperature 0 ~ 50 ℃ Storage temperature -10 ℃ ~ ...

    • Well-designed Medicine Measuring Cup - Microcomputer automatic calorimeter – Huacheng

      Well-designed Medicine Measuring Cup - Microco...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • China Factory for Pipette Multichannel - Microcomputer automatic calorimeter – Huacheng

      China Factory for Pipette Multichannel - Micro...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...