• Meteorological anemometer wind speed sensor

Meteorological anemometer wind speed sensor

Short Description:

◆ Wind speed sensors adopts traditional three- cup structure.;
◆ The cups are made from carbon fiber material, with high intensity and good start ability;
◆ The signal processing units, built in the cups, can output the corresponding;
◆ It can be widely use in meteorology, marine, environment, airport, harbor, laboratory, industry and agriculture area;
Support Custom Parameters.


Product Detail

Product Tags

Technique Parameter

Measurement range 0~45m/s 
0~70m/s
Accuracy ±(0.3+0.03V)m/s (V: wind speed)
Resolution 0.1m/s
Staring wind speed ≤0.5m/s
Power supply mode DC 5V 
DC 12V 
DC 24V 
Other
Out-put Current: 4~20mA 
Voltage: 0~2.5V 
Pulse:Pulse signal
Voltage: 0~5V    
RS232
RS485
TTL Level: (frequency; Pulse width)
Other
Instrument Line length Standard: 2.5m
Other  
Load capacity Current mode impedance≤600Ω
Voltage mode impedance≥1KΩ
Operating environment Temperature: -40℃~50℃
Humidity: ≤100%RH    
Defend grade IP45
Cable grade Nominal voltage:300V 
Temperature grade:80℃
Produce weight 130 g
Power dissipation 50 mW

Calculation Formula

Impulsive:
W =0; (f = 0)
W =0.3+0.0877×f(f≠ 0)
(W: indicating value of wind speed(m/s); f: pulse signal frequency)
Current mode (4~20mA):
W = (i-4)×45/16
(W: indicating value of wind speed (m/s); i: current type(4-20mA))
Voltage type(0~5V):
W =V/5×45
(W: indicating value of wind speed(m/s) ; V: voltage signal(0-5V))
Voltage type(0~2.5V):
W =V/2.5×45
(W: indicating value of wind speed(m/s); V: voltage signal (0-2.5V)

Wiring Method          

There is five-core aviation plug, whose output is at the base of the sensor. The definition of each pin’s corresponding base pin.

lf-001

1. If you have equipped with our company's weather station, please attach the sensor cable to the appropriate connector on the weather station directly.

2. If you purchase the sensor separately, the order of the wires are as followed:
R(Red): power +
Y(Yellow): signal output
G(Green): power —

3. Two ways of wiring method of pulse voltage and current:

wiring method of voltage and current

wiring method of voltage and current

output of current wiring method

output of current wiring method

Structure Dimensions

Structure Dimensions
Wind speed Sensor

Base mounting dimensions

Base mounting dimensions
Dimensional drawing of base installation:
Installation aperture: 4mm
Distribution Diameter: 62.5mm
Interface Dimension: 15mm (suggest reserving 25mm for wiring)

Transmitter Size

Transmitter Size   

RS485 (with address) communication protocol 

1. Serial format
8 data bits
1 stop bit
Parity None
Baud rate 9600,Two communication interval of at least 1000ms
2. The communication format
[1] Is written to the device address
Send: 00 10 00 AA (16 hexadecimal data)
Description: 00 - broadcast address (must be 0); 10 - Write operation (fixed); 00 - Address command (fixed); AA - write the new address (only,1-255)
Returns: OK (OK return success)
[2] To read the device address
Sent: 00 03 00 (hexadecimal data)
Description: 00 - broadcast address (must be 0); 03 - Read operation (fixed); 00 - Address command (fixed)
Returns: Address = XXX (ASCII code data, such as Address = 001, Address = 123, etc.)
Description: Address - address instructions; XXX - address data, less than three integer preceded 0
[1] Which units followed with a carriage return wrap data, two-byte hexadecimal data 0x0D 0x0A;
[2] The above description ignores transition spaces and '=' character.
[3] Read real-time data
Send: AA 03 0F (16 decimal data)
Description: AA - Device address (only 1-255); 03 - read operation (fixed); 0F - data address (fixed)
Back: WS = XX.Xm/s (ASCII code data, such as WS =12.3m/s, WS = 00.5m/s)
Description: WS – Wind speed; XX.X – wind speed data, bring a decimal less than two integers, the leading zeros  m/s - units
[1] Which units followed with a carriage return wrap data, two-byte hexadecimal data 0x0D 0x0A;
[2] The above description ignores transition spaces and '=' character.

LF-0001 Wind Speed Sensor01

Precautions 

1. Please examine whether the package is intact or not please, and check whether the product is consistent with your selected type.
2. Be sure no power is applied before you ensure the wiring connection is errorless.
3. No alteration to factory-set components or cables.
4. Sensor is an accurate instrument. Do not separate, damage the interface of the sensor with sharp solid and corrosive liquid.
5. Please save the verification certification and Certificate of approval which may return to repair with the products.

Troubleshooting      

1. If anemometer bearing is not rotating well or have a big delay. It may because the long-term use lead to foreign matters in the bearings or weather there is any remained lubricating oil. Please inject the oil from the upside of bearings or post the sensors to our company to oiling.
2. If the indicated value is 0 or out of range when use analog output. It may be cause by cable connections. Please check weather the cable connections are correct and fastness.
3. If not the above reasons, please contact with us.

Selection Table

No Power supply Output Signal Instructions
LF-0001     wind speed sensors (transmitters)
  5V-   5Vpower supply
12V-   12Vpower supply
24V-   24Vpower supply
YV-   Other power supply
  V 0-5V
V1 1-5V
V2 0-2.5V
A1 4-20mA
A2 0-20mA
W1 RS232
W2 RS485
TL TTL
M pulse
X other
E.g. LF-0001-5V-M: wind speed sensorstransmitters5Vpower supply, output of pulse

Appendix: Wind force (wind velocity) Scale

Scale Description Land conditions Wind speed m/s
0 Calm Calm. Smoke rises vertically. 00.2
1 Light air Smoke drift indicates wind direction, still wind vanes. 0315
2 Light breeze Wind felt on exposed skin. Leaves rustle, vanes begin to move. 1633
3 Gentle breeze Leaves and small twigs constantly moving, light flags extended. 3454
4 Moderate Dust and loose paper raised. Small branches begin to move. 5579
5 Fresh breeze Branches of a moderate size move. Small trees in leaf begin to sway. 80107
6 Strong breeze Large branches in motion. Whistling heard in overhead wires. Umbrella use becomes difficult. Empty plastic garbage cans tip over. 10813.8
7 Moderate gale Whole trees in motion. Effort needed to walk against the wind. 13917l
8 Gale Some twigs broken from trees. Cars veer on road. Progress on foot is seriously impeded. 172207
9 Strong gale Some branches break off trees, and some small trees blow over. Construction/temporary signs and barricades blow over. 208244
10 Storm Trees are broken off or uprooted, saplings bent and deformed. Poorly attached asphalt shingles and shingles in poor condition peel off roofs. 245284
11 Violent storm Widespread damage to vegetation. Many roofing surfaces are damaged; asphalt tiles that have curled up and/or fractured due to age may break away completely. 285326
12 Hurricane-force Very widespread damage to vegetation. Some windows may break; mobile homes and poorly constructed sheds and barns are damaged. Debris may be hurled about. >32.6

  • Previous:
  • Next:

  • Write your message here and send it to us

    Related products

    • WGZ-500B, 2B, 3B, 4000B Portable Turbidity Meter

      WGZ-500B, 2B, 3B, 4000B Portable Turbidity Meter

      Features  ● Portable, AC and DC power supply, with low voltage indication and automatic shutdown function. The serial RS232 communication interface can be connected with a micro printer. ● Microcomputer low-power configuration, touch keyboard, LCD screen with backlight, can display date, time, measurement value and measurement unit at the same time. ● Measuring range can be manually selected or automa...

    • CLEAN CON30 Conductivity Meter (Conductivity/TDS/Salinity)

      CLEAN CON30 Conductivity Meter (Conductivity/TD...

      Features    ●Boat-shaped floating design, IP67 waterproof grade. ●Easy operation with 4 keys, comfortable to hold, accurate value measurement with one hand. ●Extra large measurement range: 0.0 μS/cm - 20.00 mS/cm; minimum reading: 0.1 μS/cm. ●Auto range 1-point calibration: free calibration is not limited. ●CS3930 Conductivity Electrode: Graphite electrode, K=1.0, accurate, stable and anti-interf...

    • Bus transmitter Instructions

      Bus transmitter Instructions

      485 Overview 485 is a kind of serial bus which is widely used in industrial communication. 485 communication only needs two wires (line A, line B), long distance transmission is recommended to use shielded twisted pair. Theoretically, the maximum transmission distance of 485 is 4000 feet and the maximum transmission rate is 10Mb/s. The length of the balanced twisted pair is inversely proportional to t...

    • CLEAN PH30 pH Tester

      CLEAN PH30 pH Tester

      Features  ●Boat-shaped floating design, IP67 waterproof grade. ●4-button easy operation, comfortable to hold, accurate pH measurement with one hand. ●Wide application occasions: It can meet the measurement of 1ml trace samples in the laboratory to the water quality testing in the field. ●Can carry out throwing water quality measurement (automatic locking function) ●Flat electrodes can be used for skin...

    • FXB-01 Metal wind vane wind direction sensor wind vane

      FXB-01 Metal wind vane wind direction sensor wi...

      Customized 3.5-meter-high luminous metal weather vane (customizable stainless steel pole of any height) Product Description The luminous metal weather vane is placed outdoors to indicate the wind direction. The metal structure has fully realized standardized, specialized and standardized production, and the outer surface is treated with hot-dip galvanized and spray...

    • Integrated tipping bucket rainfall monitoring station Automatic rainfall station

      Integrated tipping bucket rainfall monitoring s...

      Features  ◆ It can automatically collect, record, charge, work independently, and do not need to be on duty; ◆ Power supply: using solar energy + battery: the service life is more than 5 years, and the continuous rainy working time is more than 30 days, and the battery can be fully charged for 7 consecutive sunny days; ◆ Rainfall monitoring station is a product with data collection, storage and transm...