We believe in: Innovation is our soul and spirit. High-quality is our life. Purchaser need is our God for Pipette Tips, Soil Temperature Sensor, Portable Water Quality Multi-Parameter Analyzer, And there are also many foreign friends who came for sight seeing, or entrust us to buy other stuff for them. You are most welcome to come to China, to our city and to our factory!
Hot Selling for Industrial Rain Sensor - LF-0010 TBQ Total Radiation Sensor – Huacheng Detail:

This sensor is used to measure the spectral range of 0.3-3μm, solar radiation, can also be used to measure the incident solar radiation to the slant of the reflected radiation can be measured, such as the induction downwardly facing, light shielding ring measurable scattered radiation. Therefore, it can be widely applied to the use of solar energy, meteorology, agriculture, building materials, aging and atmospheric pollution and other departments to do the measurement of solar radiation energy.

Sensitivity 7~14μV/w.m-2
Spectral range 0.3-3μm
Measuring range 0 ~ 2000W/m2
Power supply DC 5V 
DC 12V 
DC 24V 
Other
Output in the form Pulse: Pulse signal
Current: 4~20mA  
Voltage: 0~2.5V 
Voltage: 1~5V    
Voltage: 0 ~ 20mV
RS232
RS485
Other
Instrument Line length Standard: 2.5m
Other  
Response time ≤ 35 seconds (99%)
Internal resistance approximately 350Ω
Stability ≤ ± 2%
Cosine response ≤7% (solar elevation angle of 10 °)
Azimuth response error ≤5% (solar elevation angle of 10 °)
Temperature characteristics ±2% (-10 ℃ to +40 ℃)
Working ambient temperature -40 ° C ~ +50 ° C
Non-linear ≤ 2%
Weight 2.5kg

LF-0010 TBQ Total Radiation Sensor5
LF-0010 TBQ Total Radiation Sensor4
LF-0010 TBQ Total Radiation Sensor6

The sensor should be installed in the space, around the place above the sensing surface without any obstacles. Then the radiation table cable plug is on the north, adjust level position, firmly fixed, then the total radiation sensor output cable acquisition equipment connected to observation. The best cable is securely fixed to the mounting bracket to reduce the fracture or interruptions occur intermittently windy days.

Wiring instructions

Sensor name Wiring color Output Description Corresponding plug pins
TBQ Total radiation sensor Red line Positive signal output Foot 1 of the four-pin plug
Black line Negative signal output Foot 2 of the four-pin plug

1. Serial format
8 data bits
1 stop bit
Parity None
Baud rate 9600 two communication interval of at least 1000ms
2. The communication format
[1] Is written to the device address
Send: 00 10 00 AA (16 hexadecimal data)
Description: 00 – Broadcast address (must be 0); 10 – Write operation (fixed); 00 – Address command (fixed); AA -Write the new address (only,1-255)
Returns: OK (OK return success)
[2] To read the device address
Sent: 000,300 (hexadecimal data)
Description: 00 – Broadcast address (must be 0); 03 – Read operation (fixed);  00 – Address command (fixed)
Returns: Address = XXX (ASCII code data, such as Address = 001, Address = 123, etc.)
Description: Address – address instructions; XXX – Address data, less than three integers, preceded by 0;
[1] Which units followed with a carriage return wrap data, two-byte hexadecimal data 0x0D 0x0A;
[2] The above description ignores transition spaces and ‘=’ character.
[3] Read real-time data
Send: AA 03 0F (16 decimal data)
Description: AA – Device address (only 1-255); 03 – Read operation (fixed); 0F – Data address (fixed)
Returns: The TBQ = XXXX W/m2 (ASCII code data, such as TBQ = 0400 W/m2 TBQ = 1000 W/m2 etc.)
Description: TBQ – TBQ total convergence of f our integers, preceded by 0; W/m2 – units
[1] Which units followed with a carriage return wrap data, two-byte hexadecimal data 0x0D 0x0A.
[2] The above description ignores transition spaces and ‘=’ character.

The sensor wires in the wiring method according to the instructions in the, and then placed in the position for the measurement of radiation, turn on the power and collection instrument switch, you can get the radiation value of the measurement points.

1. Please check the packaging is intact, and check whether the product model is consistent with the selection.
2. Do not live wiring, the wiring is complete check correct before electricity.
3. Do not tamper with the product factory welded components or wires.
4. The sensor is a precision device, use Do not disassemble, contact with the sensor surface with sharp objects or corrosive liquid, so as to avoid damage to the product.
5. Save the certificate and certificate maintenance together with product return.

1. When analog output, showing values ​​significantly larger / smaller. Check the pass dirt or debris on the sensor sensing port; if so, with a dry net cloth to wipe away.
2. When analog output the display instrument represents a value of 0 or is not in range to within. May be due to wiring problems lead to acquisition instrument is unable to obtain the correct letter, please check the wiring is correct, firmly.
3. If the above reasons, please contact the manufacturer.

1. It is not allowed to demolition or loose filter mask, so as not to affect the measurement accuracy. Open or covered with a metal cover especially careful, because the filter mask precious and fragile. Filter mask to maintain smooth, often with a soft cloth or fur smear.
2. Filter mask should not has water, nor should be water vapor condensation hood. Desiccant desiccator should always check whether to change the tide (from blue to red or white), otherwise it must be promptly replaced or desiccant will get the oven to dry so that it changed back to blue again.
3. TBQ total radiation sensor waterproof performance is good, generally a short period of time or smaller precipitation cannot stamped. But the rainfall heavy rains (snow, ice, etc.) or a longer time, for the protection of the radiation table, observers is necessary, according to the specific circumstances of the best stamped, the rain stopped as soon as the cover is open.
4. TBQ total radiation sensor use for more than two years, re-calibration of its sensitivity by the manufacturer or metering department.

TBQ total radiation sensor from the factory on the date one year due to the non-human factors causing quality problems, the production unit is responsible for free repair or replacement. If the user man-made damage, will be charged the cost of fees, but does not charge maintenance fees. In addition, I solemnly promised to be responsible for products manufactured lifelong maintenance.

No.

Power supply

Export

Signal

Explain

LF-0010 -

 

 

TBQ total radiation sensor

(Transmitter)

 

5V-

 

5VPower supply

12V-

 

12VPower supply

24V-

 

24VPower supply

Z-

 

No power

 

V

0-5V

A1

4-20mA

A2

0-20mA

W1-

RS232

W2-

RS485

V3-

0-20mV

X-

Other

E.g.: LF-0010-12V-A: TBQ total radiation sensor 12V power supply, 4-20mA current signal output


Product detail pictures:

Hot Selling for Industrial Rain Sensor - LF-0010 TBQ Total Radiation Sensor – Huacheng detail pictures

Hot Selling for Industrial Rain Sensor - LF-0010 TBQ Total Radiation Sensor – Huacheng detail pictures

Hot Selling for Industrial Rain Sensor - LF-0010 TBQ Total Radiation Sensor – Huacheng detail pictures

Hot Selling for Industrial Rain Sensor - LF-0010 TBQ Total Radiation Sensor – Huacheng detail pictures


Related Product Guide:

With our outstanding administration, powerful technical capability and strict top quality handle procedure, we go on to provide our purchasers with reliable good quality, reasonable selling prices and excellent services. We goal at becoming certainly one of your most responsible partners and earning your gratification for Hot Selling for Industrial Rain Sensor - LF-0010 TBQ Total Radiation Sensor – Huacheng , The product will supply to all over the world, such as: Cyprus, Las Vegas, Algeria, We believe that good business relationships will lead to mutual benefits and improvement for both parties. We have established long-term and successful cooperative relationships with many customers through their confidence in our customized services and integrity in doing business. We also enjoy a high reputation through our good performance. Better performance will be expected as our principle of integrity. Devotion and Steadiness will remain as ever.
  • We have been appreciated the Chinese manufacturing, this time also did not let us disappoint,good job!
    5 Stars By Gustave from Turkey - 2018.02.21 12:14
    We have been cooperated with this company for many years, the company always ensure timely delivery ,good quality and correct number, we are good partners.
    5 Stars By Daniel Coppin from Philippines - 2018.08.12 12:27
    Write your message here and send it to us

    Related products

    • Low MOQ for Turbidimeter - Microcomputer automatic calorimeter – Huacheng

      Low MOQ for Turbidimeter - Microcomputer autom...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Special Price for Bucket Rain Gauge - Microcomputer automatic calorimeter – Huacheng

      Special Price for Bucket Rain Gauge - Microcom...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Good Wholesale Vendors  Plastic Container - Microcomputer automatic calorimeter – Huacheng

      Good Wholesale Vendors Plastic Container - Mi...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • China wholesale Test Tube And Rack - Microcomputer automatic calorimeter – Huacheng

      China wholesale Test Tube And Rack - Microcomp...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Factory Supply Chemical Oxygen Demand Reagents - Microcomputer automatic calorimeter – Huacheng

      Factory Supply Chemical Oxygen Demand Reagents ...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Best quality Soil Ec Sensor - Meteorological anemometer wind speed sensor – Huacheng

      Best quality Soil Ec Sensor - Meteorological a...

      Measurement range 0~45m/s  0~70m/s Accuracy ±(0.3+0.03V)m/s (V: wind speed) Resolution 0.1m/s Staring wind speed ≤0.5m/s Power supply mode DC 5V  DC 12V  DC 24V  Other Out-put Current: 4~20mA  Voltage: 0~2.5V  Pulse:Pulse signal Voltage: 0~5V     RS232 RS485 TTL Level: (frequency; Pulse width) Other Instrument Line length Standard: 2.5m Other   Load capacity Current mode impedance≤600Ω Voltage mode impedance≥1KΩ Operating environment Temperat...