• Hot New Products Explosion-Proof Handheld Portable Ozone Gas Detector - Single-point Wall-mounted Gas Alarm – Huacheng

Hot New Products Explosion-Proof Handheld Portable Ozone Gas Detector - Single-point Wall-mounted Gas Alarm – Huacheng

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Adhering for the theory of "quality, services, performance and growth", we have received trusts and praises from domestic and worldwide shopper for Barometric Pressure Sensor, Portable Anemometer Wind Direction, Portable Water Velocity Meter, We have been sincerely looking forward to developing very good cooperative relationships with buyers from at home and abroad for creating a vibrant foreseeable future together.
Hot New Products Explosion-Proof Handheld Portable Ozone Gas Detector - Single-point Wall-mounted Gas Alarm – Huacheng Detail:

Structure chart

● Sensor: electrochemistry, catalytic combustion, infrared, PID……
● Responding time: ≤30s
● Display mode: High brightness red digital tube
● Alarming mode: Audible alarm — above 90dB(10cm)
Light alarm –Φ10 red light-emitting diodes (leds) and external strobe lights
● Output control: AC220V 5A Active switch output
● Work pattern: continuous operation
● Working power: AC220V
● Temperature range:-20℃ ~ 50℃
● Humidity range:10 ~ 90% (RH) No condensation
● Installing mode: wall-mounted installing
● Outline dimension: 230mm×150mm×75mm
● Weight: 1800g

Table 1: Technical parameters of gas-detecting

Gas

Gas name

Technical index

Measurement range

Resolution

Alarm point

CO

Carbon monoxide

0-2000pm

1ppm

50ppm

H2S

Hydrogen sulfide

0-100ppm

1ppm

10ppm

EX

Combustible gas

0-100%LEL

1%LEL

25%LEL

O2

Oxygen

0-30%vol

0.1%vol

Low 18%vol

High 23%vol

H2

Hydrogen

0-1000pm

1ppm

35ppm

CL2

Chlorine

0-20ppm

1ppm

2ppm

NO

Nitric oxide

0-250pm

1ppm

35ppm

SO2

Sulfur dioxide

0-20ppm

1ppm

5ppm

O3

Ozone

0-50ppm

1ppm

2ppm

NO2

Nitrogen dioxide

0-20ppm

1ppm

5ppm

NH3

Ammonia

0-200ppm

1ppm

35ppm

1. Wall-mounted detecting alarm: one
2. Certificate: one
3. Manual: one
4. Installing component: one

Construction and installing

After installation and powered on,it will display the gas type, first alarm, second alarm and measuring range. After the countdown of 30S, the instrument will directly enter the working state. It has been calibrated before delivery. If it is not necessary to change the alarm parameters, the following operation is not required.
The single-point wall-mounted panel consist of the concentration indicated digital tube, the first alarm indicator, the second alarm indicator and 4 buttons.
The buttons from left to right are:
Setting button Setting button
Setting button1 Up / Down button
Setting button2 Confirmation button
Setting button Mute / Back to the former menu
Functional specification
1. Set the first and second alarm values, for oxygen alarm values is the upper and lower.
2. Restore factory Settings
3. The alarm sound can be eliminated in real time. The alarm sound will automatically start when the next alarm is given, without manual start.
4. When the gas concentration is greater than the first-level alarm value, the relay is sucked in, the buzzer alarms, and the first-level alarm indicator light is on. The state of relay is not changed when the noise is silenced in real time.
5. When the gas is combustible and the concentration exceeds 100%LEL, the instrument will automatically turn off the gas detector.
6. When menu stop operation,will automatic exit menu after 30S.

Menu operation
1. Operate steps
Enter the working state and display the detected value of the connected sensor. Setting parameters:
Step 1: Press button Setting button, display 0000, first nixie tube flashing

Operate steps1

Step 2: Enter password 1111 (user password), press button Setting button1to select one digit from 1 to 9 digits, then press buttonSetting button to select the next digit in turn (corresponding digit flashing), and then press buttonSetting button1 to select digits.
Step 3: After the password input, press button Setting button2and display F-01. You can select from F-01 to F-06 by pressing buttonSetting button1. The details of functions F-01 to F-06 refer to table 2. For example, after selecting the function F-01, press buttonSetting button2 to enter the first-level alarm setting, and the user can set the first-level alarm. After the completion of setting, press buttonSetting button2 the instrument will display F-01. If other parameters need to be set as above, otherwise, you can press buttonSetting button3 exit this setting.

Table 2: Functions F-01 to F-06 declaration

Function

Declaration

F-01

First alarm value

F-02

Second alarm value

F-03

Range(Read only)

F-04

Resolution(Read only)

F-05

Unit(Read only)

F-06

Gas type(Read only)

Note: When menu stop operation within 30 seconds, parameter setting will be automatically quit, return to concentration detection.

Function specification
F-01 First alarm value

F-01 First alarm value

By pressing button Setting button1to change value, by button Setting buttonto switch the position of the digital tube flashing. Press buttonSetting button2 to save Settings.
If the gas is oxygen, the first alarm value is the lower limit of alarm.

F-02 Second alarm value
By pressing button Setting button1to change value, by buttonSetting button to switch the position of the digital tube flashing. Press buttonSetting button2 to save Settings.
If the gas is oxygen, the first alarm value is the lower limit of alarm.

F-03 Range(Read only)
Displays the maximum range of the Instrument.

F-04 Resolution(Read only)
1 is an integer, 0.1 has one decimal place, and 0.01 has two decimal places.

F-04 Resolution(Read only

F-05 Unit(Read only)
P indicate ppm, L indicate %LEL, U indicate %vol

F-05 Unit(Read only01 F-05 Unit(Read only2 F-05 Unit(Read only03

F-06 Gas type(Read only)
The code for defining the common gas types,show in table 3 (Will use when the product is upgraded with communication function).

Table 3 gas type code description

O2 CO H2S N2 H2 CL2
GA00 GA01 GA02 GA03 GA04 GA05
SO2 NO NO2 HCHO O3 LEL
GA06 GA07 GA08 GA09 GA11 GA11

3. Special function description
Enter button Setting buttonto input the password “1234″, press buttonSetting button2 to enter the menu, now the menu will add P-01, A-01 and A-02.
P-01 Parameter recovery
S-01: Restore factory settings. During operation, users can restore factory Settings if the parameter Settings are abnormal.
S-02: Factory calibration is completed.
A-01/A-02Relay setting
The board defaults to output by one relay, the user can set it through A-01. The menu structure is shown as below

3.Special function description

After pressing buttonSetting button2 to enter A-01 menu, will display F-01, it is Relay output mode setting, the default is LE level output, press button Setting button1to change PU, PU is pulse output, Press button Setting button2to save, then return to the menu F-01. Press buttonSetting button1 to switch menu,showing F-02 is the relay pulse output time setting, the default is 3 seconds, can be set to 3~9 seconds, press button Setting button2to save settings after the completion of time input, press button Setting button3to exit settings.
Note: by default, this instrument only carries one relay, and users can choose to carry two relays. At this time, A-02 is set effectively, and the setting method is the same as A-01.

1. For the wall-mounted combustible gas detect alarm, when the concentration of combustible gas exceeds 100% LEL, the system will automatically turn off the power supply, to make the detector stop working and realize the explosion-proof function. At this time, the digital tube will always display 100, the normally open switch end of the relay is connected, two light-emitting diodes flicker, the buzzer alarm. At this point, you can press button Setting button2, the system will automatically exit the over-protection state, but if the gas concentration is still very high, the system will remain in this state. You can also turn off the power and wait for the gas concentration to drop before switching on the power to continue using.
2. After the first energization of the instrument, the sensor will have a polarization time. Generally, detecting gas takes several minutes,the polarization time of NO, HCL and other gases is relatively long. After the polarization is completed, the display value will gradually stabilize at 0, and then the instrument can enter into the normal detection state.Please pay attention to the user when using.
Tip: electrify time should be some longer in winter, can be used after the sensor’s temperature come up.

The warranty period of the gas detection instrument produced by my company is 12 months and warranty period is valid from the date of delivery. Users shall comply with the instructions. Due to the improper use, or poor working conditions, the instrument damage caused is not in the scope of the warranty. 

1. Before using the instrument, please read the instructions carefully.
2. The use of the instrument must be in accordance with the rules set in the manual operation.
3. The instrument maintenance and replacement of parts should be processed by our company or around the pit.
4. If the user is not in accordance with the above instructions to boot repair or replacement parts, the reliability of the instrument shall be the responsibility of the operator
5. The use of the instrument should also abide by the relevant domestic departments and factory equipment management laws and rules.


Product detail pictures:

Hot New Products Explosion-Proof Handheld Portable Ozone Gas Detector - Single-point Wall-mounted Gas Alarm – Huacheng detail pictures

Hot New Products Explosion-Proof Handheld Portable Ozone Gas Detector - Single-point Wall-mounted Gas Alarm – Huacheng detail pictures

Hot New Products Explosion-Proof Handheld Portable Ozone Gas Detector - Single-point Wall-mounted Gas Alarm – Huacheng detail pictures

Hot New Products Explosion-Proof Handheld Portable Ozone Gas Detector - Single-point Wall-mounted Gas Alarm – Huacheng detail pictures

Hot New Products Explosion-Proof Handheld Portable Ozone Gas Detector - Single-point Wall-mounted Gas Alarm – Huacheng detail pictures

Hot New Products Explosion-Proof Handheld Portable Ozone Gas Detector - Single-point Wall-mounted Gas Alarm – Huacheng detail pictures

Hot New Products Explosion-Proof Handheld Portable Ozone Gas Detector - Single-point Wall-mounted Gas Alarm – Huacheng detail pictures

Hot New Products Explosion-Proof Handheld Portable Ozone Gas Detector - Single-point Wall-mounted Gas Alarm – Huacheng detail pictures

Hot New Products Explosion-Proof Handheld Portable Ozone Gas Detector - Single-point Wall-mounted Gas Alarm – Huacheng detail pictures

Hot New Products Explosion-Proof Handheld Portable Ozone Gas Detector - Single-point Wall-mounted Gas Alarm – Huacheng detail pictures


Related Product Guide:

Our target should be to consolidate and improve the high-quality and repair of current goods, in the meantime regularly produce new solutions to meet unique customers' needs for Hot New Products Explosion-Proof Handheld Portable Ozone Gas Detector - Single-point Wall-mounted Gas Alarm – Huacheng , The product will supply to all over the world, such as: Spain, Birmingham, Cannes, Our team knows well the market demands in different countries, and is capable of supplying suitable quality products at the best prices to different markets. Our company has already set up a professional, creative and responsible team to develop clients with the multi-win principle.
  • Good quality, reasonable prices, rich variety and perfect after-sales service, it's nice!
    5 Stars By Margaret from Norway - 2017.09.29 11:19
    Goods just received, we are very satisfied, a very good supplier, hope to make persistent efforts to do better.
    5 Stars By Janet from Hungary - 2017.10.13 10:47
    Write your message here and send it to us

    Related products

    • Low price for 8-Way Bus Gas Control Cabinet - Portable combustible gas leak detector Operating instructions – Huacheng

      Low price for 8-Way Bus Gas Control Cabinet - ...

      ● Sensor Type: Catalytic sensor ● Detect gas: CH4/Natural gas/H2/ethyl alcohol ● Measure range: 0-100%lel or 0-10000ppm ● Alarm point: 25%lel or 2000ppm ,adjustable ● Accuracy: ≤5%F.S ● Alarm: Voice + vibration ● Language: Support English& Chinese menu switch ● Display: LCD digital display, Shell Material: ABS ● Working voltage: 3.7V ● Battery capacity: 2500mAh Lithium battery ● Charging voltage: DC5V ● Charging time: 3-5hours ● Ambient environment: -10~50℃,10~95%RH ● Product Size: 175*64...

    • Factory Cheap Hot Portable Liquid Flow Meter - Microcomputer automatic calorimeter – Huacheng

      Factory Cheap Hot Portable Liquid Flow Meter -...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Low price for Weather Sensor - Rain sensor stainless steel outdoor hydrological station – Huacheng

      Low price for Weather Sensor - Rain sensor sta...

      Water-carrying caliber Ф200 ± 0.6mm Measuring range ≤4mm / min (precipitation intensity) Resolution 0.2mm (6.28ml) Accuracy ± 4% (indoor static test, rain intensity is 2mm / min) Power supply mode DC 5V  DC 12V  DC 24V  Other Output form Current 4 ~ 20mA Switching signal: On-off of reed switch Voltage: 0~2.5V  Voltage: 0~5V     Voltage 1 ~ 5V Other Instrument line length Standard: 5 meters Other Working temperature 0 ~ 50 ℃ Storage temperature -10 ℃ ~ ...

    • Chinese Professional Decibel Meter - Microcomputer automatic calorimeter – Huacheng

      Chinese Professional Decibel Meter - Microcomp...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Factory Promotional Test Tube Racks - Laboratory products support custom laboratory various instruments and equipment – Huacheng

      Factory Promotional Test Tube Racks - Laborato...

    • 2022 High quality Portable Transit Time Flow Meter - Microcomputer automatic calorimeter – Huacheng

      2022 High quality Portable Transit Time Flow Me...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...