High definition Pump Suction Formaldehyde Gas Detector - Single-point Wall-mounted Gas Alarm – Huacheng

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

With our excellent administration, potent technical capability and strict top quality control technique, we go on to provide our consumers with trusted quality, reasonable price ranges and fantastic providers. We intention at becoming one among your most trusted partners and earning your fulfillment for Portable Flow Meter, Air Humidity Sensor, Spectrophotometer, For more information, please contact us as soon as possible!
High definition Pump Suction Formaldehyde Gas Detector - Single-point Wall-mounted Gas Alarm – Huacheng Detail:

Structure chart

● Sensor: electrochemistry, catalytic combustion, infrared, PID……
● Responding time: ≤30s
● Display mode: High brightness red digital tube
● Alarming mode: Audible alarm — above 90dB(10cm)
Light alarm –Φ10 red light-emitting diodes (leds) and external strobe lights
● Output control: AC220V 5A Active switch output
● Work pattern: continuous operation
● Working power: AC220V
● Temperature range:-20℃ ~ 50℃
● Humidity range:10 ~ 90% (RH) No condensation
● Installing mode: wall-mounted installing
● Outline dimension: 230mm×150mm×75mm
● Weight: 1800g

Table 1: Technical parameters of gas-detecting

Gas

Gas name

Technical index

Measurement range

Resolution

Alarm point

CO

Carbon monoxide

0-2000pm

1ppm

50ppm

H2S

Hydrogen sulfide

0-100ppm

1ppm

10ppm

EX

Combustible gas

0-100%LEL

1%LEL

25%LEL

O2

Oxygen

0-30%vol

0.1%vol

Low 18%vol

High 23%vol

H2

Hydrogen

0-1000pm

1ppm

35ppm

CL2

Chlorine

0-20ppm

1ppm

2ppm

NO

Nitric oxide

0-250pm

1ppm

35ppm

SO2

Sulfur dioxide

0-20ppm

1ppm

5ppm

O3

Ozone

0-50ppm

1ppm

2ppm

NO2

Nitrogen dioxide

0-20ppm

1ppm

5ppm

NH3

Ammonia

0-200ppm

1ppm

35ppm

1. Wall-mounted detecting alarm: one
2. Certificate: one
3. Manual: one
4. Installing component: one

Construction and installing

After installation and powered on,it will display the gas type, first alarm, second alarm and measuring range. After the countdown of 30S, the instrument will directly enter the working state. It has been calibrated before delivery. If it is not necessary to change the alarm parameters, the following operation is not required.
The single-point wall-mounted panel consist of the concentration indicated digital tube, the first alarm indicator, the second alarm indicator and 4 buttons.
The buttons from left to right are:
Setting button Setting button
Setting button1 Up / Down button
Setting button2 Confirmation button
Setting button Mute / Back to the former menu
Functional specification
1. Set the first and second alarm values, for oxygen alarm values is the upper and lower.
2. Restore factory Settings
3. The alarm sound can be eliminated in real time. The alarm sound will automatically start when the next alarm is given, without manual start.
4. When the gas concentration is greater than the first-level alarm value, the relay is sucked in, the buzzer alarms, and the first-level alarm indicator light is on. The state of relay is not changed when the noise is silenced in real time.
5. When the gas is combustible and the concentration exceeds 100%LEL, the instrument will automatically turn off the gas detector.
6. When menu stop operation,will automatic exit menu after 30S.

Menu operation
1. Operate steps
Enter the working state and display the detected value of the connected sensor. Setting parameters:
Step 1: Press button Setting button, display 0000, first nixie tube flashing

Operate steps1

Step 2: Enter password 1111 (user password), press button Setting button1to select one digit from 1 to 9 digits, then press buttonSetting button to select the next digit in turn (corresponding digit flashing), and then press buttonSetting button1 to select digits.
Step 3: After the password input, press button Setting button2and display F-01. You can select from F-01 to F-06 by pressing buttonSetting button1. The details of functions F-01 to F-06 refer to table 2. For example, after selecting the function F-01, press buttonSetting button2 to enter the first-level alarm setting, and the user can set the first-level alarm. After the completion of setting, press buttonSetting button2 the instrument will display F-01. If other parameters need to be set as above, otherwise, you can press buttonSetting button3 exit this setting.

Table 2: Functions F-01 to F-06 declaration

Function

Declaration

F-01

First alarm value

F-02

Second alarm value

F-03

Range(Read only)

F-04

Resolution(Read only)

F-05

Unit(Read only)

F-06

Gas type(Read only)

Note: When menu stop operation within 30 seconds, parameter setting will be automatically quit, return to concentration detection.

Function specification
F-01 First alarm value

F-01 First alarm value

By pressing button Setting button1to change value, by button Setting buttonto switch the position of the digital tube flashing. Press buttonSetting button2 to save Settings.
If the gas is oxygen, the first alarm value is the lower limit of alarm.

F-02 Second alarm value
By pressing button Setting button1to change value, by buttonSetting button to switch the position of the digital tube flashing. Press buttonSetting button2 to save Settings.
If the gas is oxygen, the first alarm value is the lower limit of alarm.

F-03 Range(Read only)
Displays the maximum range of the Instrument.

F-04 Resolution(Read only)
1 is an integer, 0.1 has one decimal place, and 0.01 has two decimal places.

F-04 Resolution(Read only

F-05 Unit(Read only)
P indicate ppm, L indicate %LEL, U indicate %vol

F-05 Unit(Read only01 F-05 Unit(Read only2 F-05 Unit(Read only03

F-06 Gas type(Read only)
The code for defining the common gas types,show in table 3 (Will use when the product is upgraded with communication function).

Table 3 gas type code description

O2 CO H2S N2 H2 CL2
GA00 GA01 GA02 GA03 GA04 GA05
SO2 NO NO2 HCHO O3 LEL
GA06 GA07 GA08 GA09 GA11 GA11

3. Special function description
Enter button Setting buttonto input the password “1234″, press buttonSetting button2 to enter the menu, now the menu will add P-01, A-01 and A-02.
P-01 Parameter recovery
S-01: Restore factory settings. During operation, users can restore factory Settings if the parameter Settings are abnormal.
S-02: Factory calibration is completed.
A-01/A-02Relay setting
The board defaults to output by one relay, the user can set it through A-01. The menu structure is shown as below

3.Special function description

After pressing buttonSetting button2 to enter A-01 menu, will display F-01, it is Relay output mode setting, the default is LE level output, press button Setting button1to change PU, PU is pulse output, Press button Setting button2to save, then return to the menu F-01. Press buttonSetting button1 to switch menu,showing F-02 is the relay pulse output time setting, the default is 3 seconds, can be set to 3~9 seconds, press button Setting button2to save settings after the completion of time input, press button Setting button3to exit settings.
Note: by default, this instrument only carries one relay, and users can choose to carry two relays. At this time, A-02 is set effectively, and the setting method is the same as A-01.

1. For the wall-mounted combustible gas detect alarm, when the concentration of combustible gas exceeds 100% LEL, the system will automatically turn off the power supply, to make the detector stop working and realize the explosion-proof function. At this time, the digital tube will always display 100, the normally open switch end of the relay is connected, two light-emitting diodes flicker, the buzzer alarm. At this point, you can press button Setting button2, the system will automatically exit the over-protection state, but if the gas concentration is still very high, the system will remain in this state. You can also turn off the power and wait for the gas concentration to drop before switching on the power to continue using.
2. After the first energization of the instrument, the sensor will have a polarization time. Generally, detecting gas takes several minutes,the polarization time of NO, HCL and other gases is relatively long. After the polarization is completed, the display value will gradually stabilize at 0, and then the instrument can enter into the normal detection state.Please pay attention to the user when using.
Tip: electrify time should be some longer in winter, can be used after the sensor’s temperature come up.

The warranty period of the gas detection instrument produced by my company is 12 months and warranty period is valid from the date of delivery. Users shall comply with the instructions. Due to the improper use, or poor working conditions, the instrument damage caused is not in the scope of the warranty. 

1. Before using the instrument, please read the instructions carefully.
2. The use of the instrument must be in accordance with the rules set in the manual operation.
3. The instrument maintenance and replacement of parts should be processed by our company or around the pit.
4. If the user is not in accordance with the above instructions to boot repair or replacement parts, the reliability of the instrument shall be the responsibility of the operator
5. The use of the instrument should also abide by the relevant domestic departments and factory equipment management laws and rules.


Product detail pictures:

High definition Pump Suction Formaldehyde Gas Detector - Single-point Wall-mounted Gas Alarm – Huacheng detail pictures

High definition Pump Suction Formaldehyde Gas Detector - Single-point Wall-mounted Gas Alarm – Huacheng detail pictures

High definition Pump Suction Formaldehyde Gas Detector - Single-point Wall-mounted Gas Alarm – Huacheng detail pictures

High definition Pump Suction Formaldehyde Gas Detector - Single-point Wall-mounted Gas Alarm – Huacheng detail pictures

High definition Pump Suction Formaldehyde Gas Detector - Single-point Wall-mounted Gas Alarm – Huacheng detail pictures

High definition Pump Suction Formaldehyde Gas Detector - Single-point Wall-mounted Gas Alarm – Huacheng detail pictures

High definition Pump Suction Formaldehyde Gas Detector - Single-point Wall-mounted Gas Alarm – Huacheng detail pictures

High definition Pump Suction Formaldehyde Gas Detector - Single-point Wall-mounted Gas Alarm – Huacheng detail pictures

High definition Pump Suction Formaldehyde Gas Detector - Single-point Wall-mounted Gas Alarm – Huacheng detail pictures

High definition Pump Suction Formaldehyde Gas Detector - Single-point Wall-mounted Gas Alarm – Huacheng detail pictures


Related Product Guide:

We're convinced that with joint endeavours, the business between us will bring us mutual benefits. We are able to guarantee you products high quality and competitive value for High definition Pump Suction Formaldehyde Gas Detector - Single-point Wall-mounted Gas Alarm – Huacheng , The product will supply to all over the world, such as: Mexico, Salt Lake City, Ethiopia, Each product is carefully made, it will make you satisfied. Our merchandise in the production process have got strictly monitored, because it is only to supply you the best quality, we'll feel confident. High production costs but low prices for our long-term cooperation. You can have a variety choices and the value of all types are same reliable. If you have any question, do not hesitate to ask us.
  • It is not easy to find such a professional and responsible provider in today's time. Hope that we can maintain long-term cooperation.
    5 Stars By Sophia from Netherlands - 2017.03.07 13:42
    Managers are visionary, they have the idea of "mutual benefits, continuous improvement and innovation", we have a pleasant conversation and Cooperation.
    5 Stars By Dorothy from Salt Lake City - 2017.03.07 13:42
    Write your message here and send it to us

    Related products

    • Good quality Large Weather Station - Dust and Noise Monitoring Station – Huacheng

      Good quality Large Weather Station - Dust and ...

      The noise and dust monitoring system can carry out continuous automatic monitoring of monitoring points in the dust monitoring area of different sound and environmental functional areas. It is a monitoring device with complete functions. It can automatically monitor data in the case of unattended, and can automatically monitor data through GPRS/CDMA mobile public network and dedicated line. network, etc. to transmit data. It is an all-weather outdoor dust monitoring system developed by itself...

    • Good Wholesale Vendors  Ambient Air Temperature - Microcomputer automatic calorimeter – Huacheng

      Good Wholesale Vendors Ambient Air Temperature...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • 2022 New Style Pipette Dropper - Microcomputer automatic calorimeter – Huacheng

      2022 New Style Pipette Dropper - Microcomputer...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • New Arrival China Hand Held Water Flow Meter - Microcomputer automatic calorimeter – Huacheng

      New Arrival China Hand Held Water Flow Meter -...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • New Arrival China Soil Temperature And Humidity Sensor - Meteorological anemometer wind speed sensor – Huacheng

      New Arrival China Soil Temperature And Humidity...

      Measurement range 0~45m/s  0~70m/s Accuracy ±(0.3+0.03V)m/s (V: wind speed) Resolution 0.1m/s Staring wind speed ≤0.5m/s Power supply mode DC 5V  DC 12V  DC 24V  Other Out-put Current: 4~20mA  Voltage: 0~2.5V  Pulse:Pulse signal Voltage: 0~5V     RS232 RS485 TTL Level: (frequency; Pulse width) Other Instrument Line length Standard: 2.5m Other   Load capacity Current mode impedance≤600Ω Voltage mode impedance≥1KΩ Operating environment Temperat...

    • Personlized Products  Essential Oil Bottles Wholesale - Microcomputer automatic calorimeter – Huacheng

      Personlized Products Essential Oil Bottles Who...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...