• High definition Pump Suction Formaldehyde Gas Detector - Portable gas sampling pump Operating instruction – Huacheng

High definition Pump Suction Formaldehyde Gas Detector - Portable gas sampling pump Operating instruction – Huacheng

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We've one of the most innovative manufacturing devices, experienced and qualified engineers and workers, recognized good quality handle systems and also a friendly experienced income team pre/after-sales support for Total Nitrogen Reagent, Wind Speed And Direction Weather Station, Ac Evaporator Temperature Sensor, our merchandise have superior popularity from the whole world as its most competive cost and our most advantage of after-sale assistance for the clients。
High definition Pump Suction Formaldehyde Gas Detector - Portable gas sampling pump Operating instruction – Huacheng Detail:

● Display: Large screen dot matrix liquid crystal display
● Resolution: 128*64
● Language: English and Chinese
● Shell materials: ABS
● Working principle: Diaphragm self-priming
● Flow: 500mL/min
● Pressure: -60kPa
● Noise: <32dB
● working voltage: 3.7V
● Battery capacity: 2500mAh Li battery
● Stand-by time: 30hours(keep pumping open)
● Charging Voltage: DC5V
● Charging Time: 3~5 hours
● Working temperature: -10~50℃
● Working Humidity: 10~95%RH(non-condensing)
● Dimension: 175*64*35(mm) Excluded pipe size, show in Figure 1.
● Weight: 235g

Outline dimension drawing

Figure 1: Outline dimension drawing

The list of standard products is shown in table 1
Table 1: Standard list

Items

Name

1

Portable gas sampling pump

2

Instruction

3

Charger

4

Certificates

Instrument description
The specification of instrument parts is shown in Figure 2 and table 2

Table 2. Parts specification

Items

Name

Parts specification

Figure 2: Parts specification

1

Display screen

2

USB charging interface

3

Up button

4

Power button

5

Down button

6

Air outlet

7

Air inlet

Connection Description
Portable gas sampling pump is used in conjunction with portable gas detector, uses hosepipe to connect the sampling pump and calibrated cover of gas detector together. Figure 3 is connection schematic diagram.

connection schematic diagram

Figure 3: connection schematic diagram

If the environment to be measured is far away, the hosepipe can be connected at the inlet elbow of the sampling pump.

Starting up
Button description is shown in table 3
Table 3 Button function instruction

Button

Function instruction

Note

Upturn, value+  
 starting Long press 3s starting up
Long press 3s enter menu
Short press to confirm operation
Long press 8s instrument restart
 

Downturn, value-  

● Long press button 3s starting up
● Plug charger, automatic starting of instrument

After starting up, the sampling pump is automatically opened, and the default flow rate is the one set last time. As shown in Figure 4:

Main screen

Figure 4: Main screen

On/off pump
In the main screen, short press button, to switch the pump status, on/off pump. Figure 5 shows the pump off status.

Pump off status

Figure 5: Pump off status

Instruction of main menu
In the main screen, long pressstarting to enter main menu show as Figure 6, press ▲or▼to select function, pressstarting to enter the corresponding function.

Main menu

Figure 6: Main menu

Menu function description:
Setting: setting the time of closing the pump on time, language setting ( Chinese and English)
Calibrate: enter calibration procedure
Shut down: instrument shutdown
Back: returns to the main screen

Setting
Setting at the main menu, press to enter, setting menu show as Figure 7.

Settings menu instruction:
Timing: the timing setting of closing the pump
Language: Chinese and English options
Back: returns to the main menu

Settings menu

Figure 7: Settings menu

Timing
Select timing from the setting menu and press startingbutton to enter. If the timing is not set, it will be displayed as shown in Figure 8:

Timer off

Figure 8: Timer off

Push ▲ button to open timer, push ▲ button again, to increase the time by 10 minutes, and press ▼ button to decrease the time by 10 minutes.

Timer on

Figure 9: Timer on

Press starting button to confirm, will return to the main screen, the main screen is shown in Figure 10, the main screen shows the timing flag, shows the remaining time at the below.

Main screen of setting timer

Figure 10: Main screen of setting timer

When the timing is over, automatically shut down the pump.
If you need to cancel the timing off function, go to the timing menu, and press ▼ button to set the time as 00:00:00 to cancel the timing off.

Language
Enter the language menu, as shown in Figure 11:
Select the language you want to display and press to confirm.

Language setting

Figure 11: Language setting

For example, if you need to switch language to Chinese: select Chinese and press starting to confirm, the screen will be displayed in Chinese.

Calibrate
Calibration need to use a flow meter. Please connect the flow meter to the air inlet of the sampling pump firstly. The connection diagram is shown in Figure. 12. After the connection is completed, perform the following operations for calibration.

Calibration connection diagram

Figure 12: Calibration connection diagram

Select calibration in the main menu and press button to enter calibration procedure. Calibration is two points calibration, the first point is 500mL/min, and the second point is 200mL/min.

The first point 500mL/min calibration
Press ▲ or ▼ button, change the duty cycle of the pump, adjust the flow meter to indicate a flow of 500mL/min. As shown in Figure 13:

Flow adjustment

Figure 13: Flow adjustment

After the adjustment, press starting button to display the storage screen as shown in Figure. 14. Select yes, press starting button to save the setting. If you do not want to save the settings, choose no, press starting to exit calibration.

Storage screen

Figure14: Storage screen

The second point 200mL/min calibration
Then enter the second point of 200mL/min calibration, press ▲ or ▼ button, adjust the flow meter to indicate a flow of 200mL/min, as shown in Figure 15:

Figure 15 Flow adjustment

Figure 15: Flow adjustment

After the adjustment, press starting button to display the storage screen as shown in Figure 16. Select yes, and press starting button to save the settings.

Figure16 Storage screen

Figure16: Storage screen

The calibration completion screen is shown in Figure 17 and then returns to the main screen.

Turn off
Go to the main menu, press ▼ button to select turn off, then press button to turn off.

Figure 17Calibration completion screen

Figure 17: Calibration completion screen

1. Do not use in the environment with high humidity
2. Do not use in the environment with large dust
3. If the instrument is not used for a long time, please charge once every 1 to 2 months.
4. If the battery is removed and reassembled, the device will not be turned on by pressingstarting button. Only by plugging in the charger and activating it, the instrument will turn on normally.
5. If the machine cannot be started or crashed, the instrument will be restarted automatically by long pressing the startingbutton for 8 seconds.


Product detail pictures:

High definition Pump Suction Formaldehyde Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

High definition Pump Suction Formaldehyde Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

High definition Pump Suction Formaldehyde Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

High definition Pump Suction Formaldehyde Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

High definition Pump Suction Formaldehyde Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

High definition Pump Suction Formaldehyde Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

High definition Pump Suction Formaldehyde Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

High definition Pump Suction Formaldehyde Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

High definition Pump Suction Formaldehyde Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

High definition Pump Suction Formaldehyde Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

High definition Pump Suction Formaldehyde Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

High definition Pump Suction Formaldehyde Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

High definition Pump Suction Formaldehyde Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures


Related Product Guide:

It is actually our accountability to satisfy your needs and effectively serve you. Your pleasure is our best reward. We're on the lookout forward for your stop by for joint growth for High definition Pump Suction Formaldehyde Gas Detector - Portable gas sampling pump Operating instruction – Huacheng , The product will supply to all over the world, such as: Ghana, Philippines, Nigeria, During in 11 years, We have participated in more than 20 exhibitions, obtains the highest praise from each customer. Our company has been devoting that "customer first" and committed to helping customers expand their business, so that they become the Big Boss !
  • Factory equipment is advanced in the industry and the product is fine workmanship, moreover the price is very cheap, value for money!
    5 Stars By Penelope from Norway - 2018.10.31 10:02
    This manufacturer can keep improving and perfecting products and service, it is in line with the rules of market competition, a competitive company.
    5 Stars By Chloe from St. Petersburg - 2017.08.28 16:02
    Write your message here and send it to us

    Related products

    • China Factory for Pipette Multichannel - Microcomputer automatic calorimeter – Huacheng

      China Factory for Pipette Multichannel - Micro...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Lowest Price for Relative Humidity And Temperature - Microcomputer automatic calorimeter – Huacheng

      Lowest Price for Relative Humidity And Temperat...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • High Quality for 3ml Plastic Transfer Pipettes - Microcomputer automatic calorimeter – Huacheng

      High Quality for 3ml Plastic Transfer Pipettes ...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Best quality Test-Tube Rack - Microcomputer automatic calorimeter – Huacheng

      Best quality Test-Tube Rack - Microcomputer au...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Massive Selection for Flowmeter - Microcomputer automatic calorimeter – Huacheng

      Massive Selection for Flowmeter - Microcompute...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Top Quality Temperature Pressure And Humidity Sensor - Rain sensor stainless steel outdoor hydrological station – Huacheng

      Top Quality Temperature Pressure And Humidity S...

      Water-carrying caliber Ф200 ± 0.6mm Measuring range ≤4mm / min (precipitation intensity) Resolution 0.2mm (6.28ml) Accuracy ± 4% (indoor static test, rain intensity is 2mm / min) Power supply mode DC 5V  DC 12V  DC 24V  Other Output form Current 4 ~ 20mA Switching signal: On-off of reed switch Voltage: 0~2.5V  Voltage: 0~5V     Voltage 1 ~ 5V Other Instrument line length Standard: 5 meters Other Working temperature 0 ~ 50 ℃ Storage temperature -10 ℃ ~ ...