• Good quality Hydrogen Sulfide Combustible Gas Oxygen Three-In-One Gas Detector -  Digital gas transmitter Instruction Manual – Huacheng

Good quality Hydrogen Sulfide Combustible Gas Oxygen Three-In-One Gas Detector - Digital gas transmitter Instruction Manual – Huacheng

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Sticking to the principle of "Super High-quality, Satisfactory service" ,We are striving to generally be a very good business partner of you for Constant Temperature Incubator, Glass Medicine Cup 30cc, Sound Measurement Device, Create Values,Serving Customer!" would be the purpose we pursue. We sincerely hope that all clients will build long-lasting and mutually effective cooperation with us.In the event you wish to get extra facts about our enterprise, Be sure to get in touch with with us now.
Good quality Hydrogen Sulfide Combustible Gas Oxygen Three-In-One Gas Detector - Digital gas transmitter Instruction Manual – Huacheng Detail:

1. Detection principle: This system through standard DC 24V power supply, real-time display and output standard 4-20mA current signal, analysis and processing to complete digital display and alarm operation.
2. Applicable objects: This system supports the standard sensor input signals. Table 1 is our gas parameters setting table (For reference only, users can set the parameters according to the needs)
Table 1 Conventional gas parameters

Detected gas Measure Range Resolution Low/High Alarm Point
EX 0-100%lel 1%lel 25%lel   /50%lel
O2 0-30%vol 0.1%vol <18%vol, >23%vol
N2 70-100%vol 0.1%vol >82%vol, <90%vol
H2S 0-200ppm 1ppm 5ppm  /10ppm
CO 0-1000ppm 1ppm 50ppm  /150ppm
CO2 0-50000ppm 1ppm 2000ppm /5000ppm
NO 0-250ppm 1ppm 10ppm  /20ppm
NO2 0-20ppm 1ppm 5ppm  /10ppm
SO2 0-100ppm 1ppm 1ppm   /5ppm
CL2 0-20ppm 1ppm 2ppm  /4ppm
H2 0-1000ppm 1ppm 35ppm / 70ppm
NH3 0-200ppm 1ppm 35ppm / 70ppm
PH3 0-20ppm 1ppm 1ppm / 2ppm
HCL 0-20ppm 1ppm 2ppm   /4ppm
O3 0-50ppm 1ppm 2ppm   /4ppm
CH2O 0-100ppm 1ppm 5ppm   /10ppm
HF 0-10ppm 1ppm 5ppm   /10ppm
VOC 0-100ppm 1ppm 10ppm   /20ppm

3. Sensor models: Infrared sensor/catalytic sensor/electrochemical sensor
4. Response time: ≤30 seconds
5. Working voltage: DC 24V
6. Using environment: Temperature: – 10 ℃ to 50 ℃
Humidity < 95%( No condensation)
7. System power: maximum power 1 W
8. Output current: 4-20 mA current output
9. Relay control port: Passive output, Max 3A/250V
10. Protection level: IP65
11. Explosion-proof certificate number: CE20,1671, Es d II C T6 Gb
12. Dimensions: 10.3 x 10.5cm
13. System connecting requirements: 3 wire connection, single wire diameter 1.0 mm or more, line length 1km or less.

Display transmitter’s factory appearance is like figure 1, there has mounting holes on the transmitter rear panel. The user only need to connect line and other actuator with the corresponding port according to the manual, and connect DC24V power, then it can work.

3.Transmitter Usage

Figure 1 Appearance

The internal wiring of the instrument is divided into display panel (upper panel) and bottom panel (lower panel). Users only need to connect the wiring on the bottom plate correctly.
Figure 2 is the diagram of the transmitter wiring board. There are three groups of wiring terminals, power communication interface, alarm lamp interface and relay interface.

Figure 2 Internal structure

Figure 2 Internal structure

Client interface connection:
(1)Power signal interface: “GND”, “Signal” , “+24V”. The signal export 4-20 mA
4-20mA transmitter wiring is like figure 3.

Figure 3 Wiring illustration

Figure 3 Wiring illustration

Note: For illustration only, the terminal sequence is not consistent with the actual equipment.
(2)Relay interface: provide a passive switch export, always open, alarm relay pull up. Use as needed.Maximum support 3A/250V.
Relay wiring is like figure 4.

Figure 4 Relay wiring

Figure 4 Relay wiring

Notice: It is need to connect AC contactor if user connect big power control device.

5.1 Panel description

As shown in Figure 5, The transmitter panel is composed of a concentration indicator, a digital tube, a status indicator lamp, a first class alarm indicator lamp, a two level alarm indicator lamp and 5 keys.
This diagram shows the studs between the panel and the bezel, After removing the bezel, observe the 5 buttons on the panel.
Under normal monitoring condition, the status indicator flashes and the digital tube shows the current measurement value. If the alarm situation occurs, the alarm light indicates level 1 or 2 alarm, and the relay will attract.

Figure 5 Panel

Figure 5 Panel

5.2 User instructions
1. Operation procedure
Set parameters
First step: Press the settings button, and the system displays 0000

User instructions

Second steps: Input password (1111 is password). The up or down button allows you to select between 0 and 9 bits, press the settings button to select the next one in turn, Then, select the numbers by using the “up” button
Third steps: After input password, press the “OK” button, if the password is correct then the system will enter the function menu, digital tube display F-01, through the “turn on” key to select the function of F-01 to F-06, all the functions in the function table 2. For example, after selecting the function item F-01, press the “OK” button, and then enter the first level alarm setting, and the user can set the alarm at the first level. When the setting is complete, press the OK key, and the system will display F-01. If you want to continue setting, repeat the above steps, or you can press the return key to exit this setting.
The function is shown in table 2:
Table 2 Function description

Function

Instruction

Note

F-01

Primary alarm value

R/W

F-02

Second alarm value

R/W

F-03

Range

R

F-04

Resolution ratio

R

F-05

Unit

R

F-06

Gas type

R

2. Functional details
● F-01 Primary alarm value
Change the value through the “up” button, and switch the position of the digital tube flashing through the “Settings” key. Press OK to save settings.
● F-02 Second alarm value
Change the value through the “up” button, and switch the position of the digital tube flashing through the “Settings” key.
Press OK to save settings.
● F-03 Range Values(Factory has been set, please do not change)
Maximum value of instrument measurement
● F-04 Resolution ratio (Only read)
1 for integers, 0.1 for one decimal, and 0.01 for two decimal places.

Functional details

● F-05 Unit settings(Only read)
P is ppm, L is %LEL, and U is %vol.

 F-05 Unit settings(Only read)F-05 Unit settings(Only read)2

● F-06 Gas type(Only read)
Digital Tube Display CO2
3. Error code description
● E-01 Over full scale
5.3 User operation Precautions
In the process, the user will set the parameters, 30 seconds without pressing any key, the system will exit the environment of setting parameters, back to the detection mode.
Note: This transmitter does not support calibration operation.

6. Common faults and handling methods
(1) System no response after power is applied. Solution: Check whether the system has electricity.
(2) Gas stable display value is beating. Solution: Check if the sensor connector is loose.
(3) If you find the digital display is not normal, turn off the power a few seconds later, then turn on.

1. Before using the instrument, please read the manual carefully.
2. The instrument must be operated in accordance with the rules specified in the instructions.
3. The maintenance of the equipment and the replacement of parts is responsible for our company or around the repair station.
4. If the user does not follow the above instructions without authorization to start repairing or replacing parts, the reliability of the instrument is responsible for the operator.

The use of the instrument should also comply with the relevant domestic departments and factories within the instrument management laws and regulations.


Product detail pictures:

Good quality Hydrogen Sulfide Combustible Gas Oxygen Three-In-One Gas Detector -  Digital gas transmitter Instruction Manual – Huacheng detail pictures

Good quality Hydrogen Sulfide Combustible Gas Oxygen Three-In-One Gas Detector -  Digital gas transmitter Instruction Manual – Huacheng detail pictures

Good quality Hydrogen Sulfide Combustible Gas Oxygen Three-In-One Gas Detector -  Digital gas transmitter Instruction Manual – Huacheng detail pictures

Good quality Hydrogen Sulfide Combustible Gas Oxygen Three-In-One Gas Detector -  Digital gas transmitter Instruction Manual – Huacheng detail pictures

Good quality Hydrogen Sulfide Combustible Gas Oxygen Three-In-One Gas Detector -  Digital gas transmitter Instruction Manual – Huacheng detail pictures

Good quality Hydrogen Sulfide Combustible Gas Oxygen Three-In-One Gas Detector -  Digital gas transmitter Instruction Manual – Huacheng detail pictures

Good quality Hydrogen Sulfide Combustible Gas Oxygen Three-In-One Gas Detector -  Digital gas transmitter Instruction Manual – Huacheng detail pictures

Good quality Hydrogen Sulfide Combustible Gas Oxygen Three-In-One Gas Detector -  Digital gas transmitter Instruction Manual – Huacheng detail pictures

Good quality Hydrogen Sulfide Combustible Gas Oxygen Three-In-One Gas Detector -  Digital gas transmitter Instruction Manual – Huacheng detail pictures

Good quality Hydrogen Sulfide Combustible Gas Oxygen Three-In-One Gas Detector -  Digital gas transmitter Instruction Manual – Huacheng detail pictures


Related Product Guide:

We can normally fulfill our respected consumers with our great excellent, great value and good provider due to we're much more specialist and extra hard-working and do it in cost-effective way for Good quality Hydrogen Sulfide Combustible Gas Oxygen Three-In-One Gas Detector - Digital gas transmitter Instruction Manual – Huacheng , The product will supply to all over the world, such as: Angola, Doha, Nepal, We sincerely hope to cooperate with customers all over the world, if you would like to have more information, please kindly contact us, we are looking forward to building up a great business relationship with you.
  • High production efficiency and good product quality, fast delivery and completed after-sale protection, a right choice, a best choice.
    5 Stars By Lorraine from Ottawa - 2017.09.26 12:12
    It can be said that this is a best producer we encountered in China in this industry, we feel lucky to work with so excellent manufacturer.
    5 Stars By Lena from Luxembourg - 2017.01.28 18:53
    Write your message here and send it to us

    Related products

    • China New Product  Laboratory Toppette - Microcomputer automatic calorimeter – Huacheng

      China New Product Laboratory Toppette - Micro...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Hot sale Factory Test Tube Grip Rack - Microcomputer automatic calorimeter – Huacheng

      Hot sale Factory Test Tube Grip Rack - Microco...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • New Arrival China Hand Held Water Flow Meter - Microcomputer automatic calorimeter – Huacheng

      New Arrival China Hand Held Water Flow Meter -...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Competitive Price for Automatic Pipettes Laboratory - Microcomputer automatic calorimeter – Huacheng

      Competitive Price for Automatic Pipettes Labora...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • 2022 High quality Portable Transit Time Flow Meter - Microcomputer automatic calorimeter – Huacheng

      2022 High quality Portable Transit Time Flow Me...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Free sample for Outdoor Air Sensor - Soil temperature and humidity sensor soil transmitter – Huacheng

      Free sample for Outdoor Air Sensor - Soil temp...

      Measurement range soil moisture 0 ~ 100% soil temperature -20 ~ 50 ℃ Soil wet resolution 0.1% Temperature resolution 0.1 ℃ Soil wet accuracy ± 3% Temperature accuracy ± 0.5 ℃ Power supply mode DC 5V  DC 12V  DC 24V  Other Output form Current: 4~20mA  Voltage: 0~2.5V  Voltage: 0~5V     RS232 RS485 TTL Level: (frequency; Pulse width) Other Load resistance Voltage type: RL≥1K Current type: RL≤250Ω Working temperature -50 ℃ ~ 80 ℃ Relative humidity 0 ...