In an effort to provide you advantage and enlarge our business enterprise, we even have inspectors in QC Staff and assure you our greatest provider and item for Low Beaker, Sensor Atmospheric Pressure, Large Pipette, If you are interested in any of our products, please feel free to contact us for more details. We hope to cooperate with more friends from all over the world.
Free sample for Outdoor Air Sensor - Soil temperature and humidity sensor soil transmitter – Huacheng Detail:

Measurement range soil moisture 0 ~ 100% soil temperature -20 ~ 50 ℃
Soil wet resolution 0.1%
Temperature resolution 0.1 ℃
Soil wet accuracy ± 3%
Temperature accuracy ± 0.5 ℃
Power supply mode DC 5V 
DC 12V 
DC 24V 
Other
Output form Current: 4~20mA 
Voltage: 0~2.5V 
Voltage: 0~5V    
RS232
RS485
TTL Level: (frequency; Pulse width)
Other
Load resistance Voltage type: RL≥1K
Current type: RL≤250Ω
Working temperature -50 ℃ ~ 80 ℃
Relative humidity 0 to 100%
Product weight 220 g probe with transmitter 570 g
Product power consumption about 420 mW

Soil humidity:
Voltage type (0 ~ 5V output):
R = V / 5 × 100%
(R is the soil moisture value and V is the output voltage value (V))
Current type (4 ~ 20mA output):
R = (I-4) / 16 × 100%
(R is the soil moisture value, I is the output current value (mA))

Soil temperature:
Voltage type (0 ~ 5V output):
T = V / 5 × 70-20
(T is the measured temperature value (℃), V is the output voltage value (V), this formula corresponds to the measurement range -20 ~ 50 ℃)
Current type (4 ~ 20mA)
T = (I-4) / 16 × 70 -20
(T is the measured temperature value (℃), I is the output current (mA), this formula corresponds to the measurement range -20 ~ 50 ℃)

1. If equipped with a weather station produced by the company, directly connect the sensor to the corresponding interface on the weather station using a sensor line;

2. If the transmitter is purchased separately, the corresponding line sequence of the transmitter is:

Line color Output signal
Voltage Current communication
Red Power + Power + Power +
Black(green) Power ground Power ground Power ground
Yellow Voltage signal Current signal A+/TX
Blue     B-/RX

Transmitter voltage and current output wiring:

Wiring for voltage output mode

Wiring for voltage output mode

Wiring for voltage output mode 1

Wiring for current output mode

Structure Dimensions

Structure Dimensions

Structure Dimensions 1

Sensor Size

1. The serial format
Data bits 8 bits
Stop bit 1 or 2
Check Digit None
Baud rate 9600 Communication interval is at least 1000ms
2. Communication format
[1] Write device address
Send: 00 10 Adress CRC (5 bytes)
Returns: 00 10 CRC (4 bytes)
Note: 1. The address bit of the read and write address command must be 00. 2. Adress is 1 byte and the range is 0-255.
Example: Send 00 10 01 BD C0
Returns 00 10 00 7C
[2] Read device address
Send: 00 20 CRC (4 bytes)
Returns: 00 20 Adress CRC (5 bytes)
Explanation: Adress is 1 byte, the range is 0-255
For example: Send 00 20 00 68
Returns 00 20 01 A9 C0
[3] Read real-time data
Send: Adress 03 00 00 00 02 XX XX
Note: as shown below

Code Function definition Note
Adress Station number (address)  
03 Function code  
00  00 Initial address  
00  02 Read points  
XX XX CRC Check code,front low later high  

Returns: Adress 03 04 XX XX XX XX YY YY
Note

Code Function definition Note
Adress Station number (address)  
03 Function code  
04 Read unit byte  
XX  XX Soil temperature data (high before, low after) Hex
XX  XX Soil humidity data (high before, low after) Hex
YY  YY CRCCheck code  

To calculate the CRC code:
1. The preset 16-bit register is FFFF in hexadecimal (that is, all are 1). Call this register the CRC register.
2. XOR the first 8-bit data with the lower bit of the 16-bit CRC register and put the result in the CRC register.
3. Shift the contents of the register to the right by one bit (toward the low bit), fill the highest bit with 0, and check the lowest bit.
4. If the least significant bit is 0: repeat step 3 (shift again), if the least significant bit is 1: the CRC register is XORed with the polynomial A001 (1010 0000 0000 0001).
5. Repeat steps 3 and 4 until 8 times to the right, so that the entire 8-bit data has been processed.
6. Repeat steps 2 to 5 for the next 8-bit data processing.
7. The CRC register finally obtained is the CRC code.
8. When the CRC result is put into the information frame, the high and low bits are exchanged, and the low bit is first.

Connect the sensor according to the instructions in the wiring method, then insert the probe pins of the sensor into the soil to measure humidity, and turn on the power and the collector switch to obtain the soil temperature and humidity at the measurement point.

1. Please check whether the packaging is intact and check whether the product model is consistent with the selection.
2. Do not connect with power on, and then power on after checking the wiring.
3. Do not arbitrarily change the components or wires that have been soldered when the product leaves the factory.
4. The sensor is a precision device. Please do not disassemble it by yourself or touch the surface of the sensor with sharp objects or corrosive liquids in order to avoid damaging the product.
5. Please keep the verification certificate and certificate of conformity, and return it with the product when repairing.

1. When the output is detected, the display indicates that the value is 0 or is out of range. Check whether there is obstruction from foreign objects. The collector may not be able to obtain the information correctly due to wiring problems. Please check whether the wiring is correct and firm;
2. If it is not the above reasons, please contact the manufacturer.

No Power supply Output Signal Instructions
LF-0008-     Soil temperature and humidity sensor
 
 
5V-   5V power supply
12V-   12V power supply
24V-   24V power supply
YV-   Other power
  V 0-5V
V2 0-2.5V
A1 4-20mA
W1 RS232
W2 RS485
TL TTL
M Pulse
X Other
E.g.:  LF-0008-12V-A1:Soil temperature and humidity sensor 12V power supply, 4-20mA current signal output

Product detail pictures:

Free sample for Outdoor Air Sensor - Soil temperature and humidity sensor soil transmitter – Huacheng detail pictures

Free sample for Outdoor Air Sensor - Soil temperature and humidity sensor soil transmitter – Huacheng detail pictures

Free sample for Outdoor Air Sensor - Soil temperature and humidity sensor soil transmitter – Huacheng detail pictures

Free sample for Outdoor Air Sensor - Soil temperature and humidity sensor soil transmitter – Huacheng detail pictures

Free sample for Outdoor Air Sensor - Soil temperature and humidity sensor soil transmitter – Huacheng detail pictures

Free sample for Outdoor Air Sensor - Soil temperature and humidity sensor soil transmitter – Huacheng detail pictures

Free sample for Outdoor Air Sensor - Soil temperature and humidity sensor soil transmitter – Huacheng detail pictures


Related Product Guide:

We are proud of the superior customer gratification and wide acceptance due to our persistent pursuit of top of the range both of those on merchandise and service for Free sample for Outdoor Air Sensor - Soil temperature and humidity sensor soil transmitter – Huacheng , The product will supply to all over the world, such as: Berlin, Pakistan, Senegal, We'd like to invite customers from abroad to discuss business with us. We can present our clients with high quality products and excellent service. We're sure that we'll have good cooperative relationships and make a brilliant future for both parties.
  • Although we are a small company, we are also respected. Reliable quality, sincere service and good credit, we are honored to be able to work with you!
    5 Stars By Dawn from Curacao - 2017.05.21 12:31
    Products and services are very good, our leader is very satisfied with this procurement, it is better than we expected,
    5 Stars By Prima from Amsterdam - 2017.02.28 14:19
    Write your message here and send it to us

    Related products

    • Bottom price Pm2.5 Sensor - LF-0020 water temperature sensor – Huacheng

      Bottom price Pm2.5 Sensor - LF-0020 water temp...

      Measurement range -50~100℃ -20~50℃ Accuracy ±0.5℃ Power supply DC 2.5V  DC 5V  DC 12V  DC 24V  Other Out-put Current: 4~20mA  Voltage: 0~2.5V  Voltage: 0~5V     RS232 RS485 TTL Level: (frequency; Pulse width) Other Line length Standard: 10 meters Other   Load capacity Current output impedance≤300Ω Voltage output impedance≥1KΩ Operating environment Temperature: -50℃~80℃ Humidity: ≤100%RH     Produce weight Probe 145 g, with collector 550 g P...

    • China wholesale Noise Monitoring Station Manufacturers - Microcomputer automatic calorimeter – Huacheng

      China wholesale Noise Monitoring Station Manufa...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • OEM China Ambient Air Temp Sensor - Soil temperature and humidity sensor soil transmitter – Huacheng

      OEM China Ambient Air Temp Sensor - Soil tempe...

      Measurement range soil moisture 0 ~ 100% soil temperature -20 ~ 50 ℃ Soil wet resolution 0.1% Temperature resolution 0.1 ℃ Soil wet accuracy ± 3% Temperature accuracy ± 0.5 ℃ Power supply mode DC 5V  DC 12V  DC 24V  Other Output form Current: 4~20mA  Voltage: 0~2.5V  Voltage: 0~5V     RS232 RS485 TTL Level: (frequency; Pulse width) Other Load resistance Voltage type: RL≥1K Current type: RL≤250Ω Working temperature -50 ℃ ~ 80 ℃ Relative humidity 0 ...

    • Factory wholesale Transfer Pipette - Microcomputer automatic calorimeter – Huacheng

      Factory wholesale Transfer Pipette - Microcomp...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • High Quality Cod Bod Analyzer - Microcomputer automatic calorimeter – Huacheng

      High Quality Cod Bod Analyzer - Microcomputer ...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • High definition Pump Suction Formaldehyde Gas Detector - Single-point Wall-mounted Gas Alarm – Huacheng

      High definition Pump Suction Formaldehyde Gas D...

      ● Sensor: catalytic combustion ● Responding time: ≤40s (conventional type) ● Work pattern: continuous operation, high and low alarm point(could be set) ● Analog interface: 4-20mA signal output [option] ● Digital interface: RS485-bus interface [option] ● Display mode: Graphic LCD ● Alarming mode: Audible alarm — above 90dB; Light alarm — High intensity strobes ● Output control: relay output with two way alarming control ● Additional function: time display、calendar display ● Storag...