1. Detection principle: This system through standard DC 24V power supply, real-time display and output standard 4-20mA current signal, analysis and processing to complete digital display and alarm operation.
2. Applicable objects: This system supports the standard sensor input signals. Table 1 is our gas parameters setting table (For reference only, users can set the parameters according to the needs)
Table 1 Conventional gas parameters

Detected gas Measure Range Resolution Low/High Alarm Point
EX 0-100%lel 1%lel 25%lel   /50%lel
O2 0-30%vol 0.1%vol <18%vol, >23%vol
N2 70-100%vol 0.1%vol >82%vol, <90%vol
H2S 0-200ppm 1ppm 5ppm  /10ppm
CO 0-1000ppm 1ppm 50ppm  /150ppm
CO2 0-50000ppm 1ppm 2000ppm /5000ppm
NO 0-250ppm 1ppm 10ppm  /20ppm
NO2 0-20ppm 1ppm 5ppm  /10ppm
SO2 0-100ppm 1ppm 1ppm   /5ppm
CL2 0-20ppm 1ppm 2ppm  /4ppm
H2 0-1000ppm 1ppm 35ppm / 70ppm
NH3 0-200ppm 1ppm 35ppm / 70ppm
PH3 0-20ppm 1ppm 1ppm / 2ppm
HCL 0-20ppm 1ppm 2ppm   /4ppm
O3 0-50ppm 1ppm 2ppm   /4ppm
CH2O 0-100ppm 1ppm 5ppm   /10ppm
HF 0-10ppm 1ppm 5ppm   /10ppm
VOC 0-100ppm 1ppm 10ppm   /20ppm

3. Sensor models: Infrared sensor/catalytic sensor/electrochemical sensor
4. Response time: ≤30 seconds
5. Working voltage: DC 24V
6. Using environment: Temperature: – 10 ℃ to 50 ℃
Humidity < 95%( No condensation)
7. System power: maximum power 1 W
8. Output current: 4-20 mA current output
9. Relay control port: Passive output, Max 3A/250V
10. Protection level: IP65
11. Explosion-proof certificate number: CE20,1671, Es d II C T6 Gb
12. Dimensions: 10.3 x 10.5cm
13. System connecting requirements: 3 wire connection, single wire diameter 1.0 mm or more, line length 1km or less.

Display transmitter’s factory appearance is like figure 1, there has mounting holes on the transmitter rear panel. The user only need to connect line and other actuator with the corresponding port according to the manual, and connect DC24V power, then it can work.

3.Transmitter Usage

Figure 1 Appearance

The internal wiring of the instrument is divided into display panel (upper panel) and bottom panel (lower panel). Users only need to connect the wiring on the bottom plate correctly.
Figure 2 is the diagram of the transmitter wiring board. There are three groups of wiring terminals, power communication interface, alarm lamp interface and relay interface.

Figure 2 Internal structure

Figure 2 Internal structure

Client interface connection:
(1)Power signal interface: “GND”, “Signal” , “+24V”. The signal export 4-20 mA
4-20mA transmitter wiring is like figure 3.

Figure 3 Wiring illustration

Figure 3 Wiring illustration

Note: For illustration only, the terminal sequence is not consistent with the actual equipment.
(2)Relay interface: provide a passive switch export, always open, alarm relay pull up. Use as needed.Maximum support 3A/250V.
Relay wiring is like figure 4.

Figure 4 Relay wiring

Figure 4 Relay wiring

Notice: It is need to connect AC contactor if user connect big power control device.

5.1 Panel description

As shown in Figure 5, The transmitter panel is composed of a concentration indicator, a digital tube, a status indicator lamp, a first class alarm indicator lamp, a two level alarm indicator lamp and 5 keys.
This diagram shows the studs between the panel and the bezel, After removing the bezel, observe the 5 buttons on the panel.
Under normal monitoring condition, the status indicator flashes and the digital tube shows the current measurement value. If the alarm situation occurs, the alarm light indicates level 1 or 2 alarm, and the relay will attract.

Figure 5 Panel

Figure 5 Panel

5.2 User instructions
1. Operation procedure
Set parameters
First step: Press the settings button, and the system displays 0000

User instructions

Second steps: Input password (1111 is password). The up or down button allows you to select between 0 and 9 bits, press the settings button to select the next one in turn, Then, select the numbers by using the “up” button
Third steps: After input password, press the “OK” button, if the password is correct then the system will enter the function menu, digital tube display F-01, through the “turn on” key to select the function of F-01 to F-06, all the functions in the function table 2. For example, after selecting the function item F-01, press the “OK” button, and then enter the first level alarm setting, and the user can set the alarm at the first level. When the setting is complete, press the OK key, and the system will display F-01. If you want to continue setting, repeat the above steps, or you can press the return key to exit this setting.
The function is shown in table 2:
Table 2 Function description

Function

Instruction

Note

F-01

Primary alarm value

R/W

F-02

Second alarm value

R/W

F-03

Range

R

F-04

Resolution ratio

R

F-05

Unit

R

F-06

Gas type

R

2. Functional details
● F-01 Primary alarm value
Change the value through the “up” button, and switch the position of the digital tube flashing through the “Settings” key. Press OK to save settings.
● F-02 Second alarm value
Change the value through the “up” button, and switch the position of the digital tube flashing through the “Settings” key.
Press OK to save settings.
● F-03 Range Values(Factory has been set, please do not change)
Maximum value of instrument measurement
● F-04 Resolution ratio (Only read)
1 for integers, 0.1 for one decimal, and 0.01 for two decimal places.

Functional details

● F-05 Unit settings(Only read)
P is ppm, L is %LEL, and U is %vol.

 F-05 Unit settings(Only read)F-05 Unit settings(Only read)2

● F-06 Gas type(Only read)
Digital Tube Display CO2
3. Error code description
● E-01 Over full scale
5.3 User operation Precautions
In the process, the user will set the parameters, 30 seconds without pressing any key, the system will exit the environment of setting parameters, back to the detection mode.
Note: This transmitter does not support calibration operation.

6. Common faults and handling methods
(1) System no response after power is applied. Solution: Check whether the system has electricity.
(2) Gas stable display value is beating. Solution: Check if the sensor connector is loose.
(3) If you find the digital display is not normal, turn off the power a few seconds later, then turn on.

1. Before using the instrument, please read the manual carefully.
2. The instrument must be operated in accordance with the rules specified in the instructions.
3. The maintenance of the equipment and the replacement of parts is responsible for our company or around the repair station.
4. If the user does not follow the above instructions without authorization to start repairing or replacing parts, the reliability of the instrument is responsible for the operator.

The use of the instrument should also comply with the relevant domestic departments and factories within the instrument management laws and regulations.


Product detail pictures:

Factory wholesale Portable 6-In-1 Gas Detector –  Digital gas transmitter Instruction Manual – Huacheng detail pictures

Factory wholesale Portable 6-In-1 Gas Detector –  Digital gas transmitter Instruction Manual – Huacheng detail pictures

Factory wholesale Portable 6-In-1 Gas Detector –  Digital gas transmitter Instruction Manual – Huacheng detail pictures

Factory wholesale Portable 6-In-1 Gas Detector –  Digital gas transmitter Instruction Manual – Huacheng detail pictures

Factory wholesale Portable 6-In-1 Gas Detector –  Digital gas transmitter Instruction Manual – Huacheng detail pictures

Factory wholesale Portable 6-In-1 Gas Detector –  Digital gas transmitter Instruction Manual – Huacheng detail pictures

Factory wholesale Portable 6-In-1 Gas Detector –  Digital gas transmitter Instruction Manual – Huacheng detail pictures

Factory wholesale Portable 6-In-1 Gas Detector –  Digital gas transmitter Instruction Manual – Huacheng detail pictures

Factory wholesale Portable 6-In-1 Gas Detector –  Digital gas transmitter Instruction Manual – Huacheng detail pictures

Factory wholesale Portable 6-In-1 Gas Detector –  Digital gas transmitter Instruction Manual – Huacheng detail pictures


Related Product Guide:

We take "customer-friendly, quality-oriented, integrative, innovative" as objectives. "Truth and honesty" is our administration ideal for Factory wholesale Portable 6-In-1 Gas Detector – Digital gas transmitter Instruction Manual – Huacheng , The product will supply to all over the world, such as: Israel, Iceland, Liberia, If you are interested in any of our products and solutions or would like to discuss a custom order, remember to feel free to contact us. We are looking forward to forming successful business relationships with new clients around the world in the near future.
  • The supplier abide the theory of "quality the basic, trust the first and management the advanced" so that they can ensure a reliable product quality and stable customers.
    5 Stars By Denise from Rome - 2017.06.22 12:49
    A good manufacturers, we have cooperated twice, good quality and good service attitude.
    5 Stars By Doris from United Arab Emirates - 2018.10.01 14:14
    Write your message here and send it to us

    Related products

    • New Fashion Design for Barometric Pressure Gauge - Laboratory products support custom laboratory various instruments and equipment – Huacheng

      New Fashion Design for Barometric Pressure Gaug...

    • Manufacturer for Automatic Rain Gauge - Microcomputer automatic calorimeter – Huacheng

      Manufacturer for Automatic Rain Gauge - Microc...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • 2022 High quality Portable Transit Time Flow Meter - Microcomputer automatic calorimeter – Huacheng

      2022 High quality Portable Transit Time Flow Me...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Hot New Products Air Temperature And Humidity Sensor - Meteorological anemometer wind speed sensor – Huacheng

      Hot New Products Air Temperature And Humidity S...

      Measurement range 0~45m/s  0~70m/s Accuracy ±(0.3+0.03V)m/s (V: wind speed) Resolution 0.1m/s Staring wind speed ≤0.5m/s Power supply mode DC 5V  DC 12V  DC 24V  Other Out-put Current: 4~20mA  Voltage: 0~2.5V  Pulse:Pulse signal Voltage: 0~5V     RS232 RS485 TTL Level: (frequency; Pulse width) Other Instrument Line length Standard: 2.5m Other   Load capacity Current mode impedance≤600Ω Voltage mode impedance≥1KΩ Operating environment Temperat...

    • Chinese Professional Portable Flammable Gas Concentration Meter Alarm - Single-point Wall-mounted Gas Alarm Instruction Manual (Chlorine) – Huacheng

      Chinese Professional Portable Flammable Gas Con...

      ● Sensor: catalytic combustion ● Responding time: ≤40s (conventional type) ● Work pattern: continuous operation, high and low alarm point(could be set) ● Analog interface: 4-20mA signal output[option] ● Digital interface: RS485-bus interface [option] ● Display mode: Graphic LCD ● Alarming mode: Audible alarm — above 90dB; Light alarm — High intensity strobes ● Output control: relay output with two way alarming control ● Additional function: time display, calendar display ● Storage...

    • High reputation Home Weather Station With Barometric Pressure – Multifunctional Automatic Weather Station – Huacheng

      High reputation Home Weather Station With Barom...

      Working environment: -40℃~+70℃; Main functions: Provide 10-minute instantaneous value, hourly instantaneous value, daily report, monthly report, annual report; users can customize the data collection time period; Power supply mode: mains or 12v direct current, and optional solar battery and other power supply modes; Communication interface: standard RS232; GPRS/CDMA; Storage capacity: The lower computer stores data cyclically, and the storage time length of the system service software c...