We now have several exceptional workers customers good at marketing, QC, and working with types of troublesome trouble during the creation system for Rain Gauge For Soil Moisture, Straw, Portable Transit Time Flow Meter, Please send us your specifications and requirements, or feel free to contact us with any questions or inquiries that you may have.
Factory wholesale Carbon Monoxide Gas Detector - Portable gas sampling pump Operating instruction – Huacheng Detail:

● Display: Large screen dot matrix liquid crystal display
● Resolution: 128*64
● Language: English and Chinese
● Shell materials: ABS
● Working principle: Diaphragm self-priming
● Flow: 500mL/min
● Pressure: -60kPa
● Noise: <32dB
● working voltage: 3.7V
● Battery capacity: 2500mAh Li battery
● Stand-by time: 30hours(keep pumping open)
● Charging Voltage: DC5V
● Charging Time: 3~5 hours
● Working temperature: -10~50℃
● Working Humidity: 10~95%RH(non-condensing)
● Dimension: 175*64*35(mm) Excluded pipe size, show in Figure 1.
● Weight: 235g

Outline dimension drawing

Figure 1: Outline dimension drawing

The list of standard products is shown in table 1
Table 1: Standard list

Items

Name

1

Portable gas sampling pump

2

Instruction

3

Charger

4

Certificates

Instrument description
The specification of instrument parts is shown in Figure 2 and table 2

Table 2. Parts specification

Items

Name

Parts specification

Figure 2: Parts specification

1

Display screen

2

USB charging interface

3

Up button

4

Power button

5

Down button

6

Air outlet

7

Air inlet

Connection Description
Portable gas sampling pump is used in conjunction with portable gas detector, uses hosepipe to connect the sampling pump and calibrated cover of gas detector together. Figure 3 is connection schematic diagram.

connection schematic diagram

Figure 3: connection schematic diagram

If the environment to be measured is far away, the hosepipe can be connected at the inlet elbow of the sampling pump.

Starting up
Button description is shown in table 3
Table 3 Button function instruction

Button

Function instruction

Note

Upturn, value+  
 starting Long press 3s starting up
Long press 3s enter menu
Short press to confirm operation
Long press 8s instrument restart
 

Downturn, value-  

● Long press button 3s starting up
● Plug charger, automatic starting of instrument

After starting up, the sampling pump is automatically opened, and the default flow rate is the one set last time. As shown in Figure 4:

Main screen

Figure 4: Main screen

On/off pump
In the main screen, short press button, to switch the pump status, on/off pump. Figure 5 shows the pump off status.

Pump off status

Figure 5: Pump off status

Instruction of main menu
In the main screen, long pressstarting to enter main menu show as Figure 6, press ▲or▼to select function, pressstarting to enter the corresponding function.

Main menu

Figure 6: Main menu

Menu function description:
Setting: setting the time of closing the pump on time, language setting ( Chinese and English)
Calibrate: enter calibration procedure
Shut down: instrument shutdown
Back: returns to the main screen

Setting
Setting at the main menu, press to enter, setting menu show as Figure 7.

Settings menu instruction:
Timing: the timing setting of closing the pump
Language: Chinese and English options
Back: returns to the main menu

Settings menu

Figure 7: Settings menu

Timing
Select timing from the setting menu and press startingbutton to enter. If the timing is not set, it will be displayed as shown in Figure 8:

Timer off

Figure 8: Timer off

Push ▲ button to open timer, push ▲ button again, to increase the time by 10 minutes, and press ▼ button to decrease the time by 10 minutes.

Timer on

Figure 9: Timer on

Press starting button to confirm, will return to the main screen, the main screen is shown in Figure 10, the main screen shows the timing flag, shows the remaining time at the below.

Main screen of setting timer

Figure 10: Main screen of setting timer

When the timing is over, automatically shut down the pump.
If you need to cancel the timing off function, go to the timing menu, and press ▼ button to set the time as 00:00:00 to cancel the timing off.

Language
Enter the language menu, as shown in Figure 11:
Select the language you want to display and press to confirm.

Language setting

Figure 11: Language setting

For example, if you need to switch language to Chinese: select Chinese and press starting to confirm, the screen will be displayed in Chinese.

Calibrate
Calibration need to use a flow meter. Please connect the flow meter to the air inlet of the sampling pump firstly. The connection diagram is shown in Figure. 12. After the connection is completed, perform the following operations for calibration.

Calibration connection diagram

Figure 12: Calibration connection diagram

Select calibration in the main menu and press button to enter calibration procedure. Calibration is two points calibration, the first point is 500mL/min, and the second point is 200mL/min.

The first point 500mL/min calibration
Press ▲ or ▼ button, change the duty cycle of the pump, adjust the flow meter to indicate a flow of 500mL/min. As shown in Figure 13:

Flow adjustment

Figure 13: Flow adjustment

After the adjustment, press starting button to display the storage screen as shown in Figure. 14. Select yes, press starting button to save the setting. If you do not want to save the settings, choose no, press starting to exit calibration.

Storage screen

Figure14: Storage screen

The second point 200mL/min calibration
Then enter the second point of 200mL/min calibration, press ▲ or ▼ button, adjust the flow meter to indicate a flow of 200mL/min, as shown in Figure 15:

Figure 15 Flow adjustment

Figure 15: Flow adjustment

After the adjustment, press starting button to display the storage screen as shown in Figure 16. Select yes, and press starting button to save the settings.

Figure16 Storage screen

Figure16: Storage screen

The calibration completion screen is shown in Figure 17 and then returns to the main screen.

Turn off
Go to the main menu, press ▼ button to select turn off, then press button to turn off.

Figure 17Calibration completion screen

Figure 17: Calibration completion screen

1. Do not use in the environment with high humidity
2. Do not use in the environment with large dust
3. If the instrument is not used for a long time, please charge once every 1 to 2 months.
4. If the battery is removed and reassembled, the device will not be turned on by pressingstarting button. Only by plugging in the charger and activating it, the instrument will turn on normally.
5. If the machine cannot be started or crashed, the instrument will be restarted automatically by long pressing the startingbutton for 8 seconds.


Product detail pictures:

Factory wholesale Carbon Monoxide Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

Factory wholesale Carbon Monoxide Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

Factory wholesale Carbon Monoxide Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

Factory wholesale Carbon Monoxide Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

Factory wholesale Carbon Monoxide Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

Factory wholesale Carbon Monoxide Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

Factory wholesale Carbon Monoxide Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

Factory wholesale Carbon Monoxide Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

Factory wholesale Carbon Monoxide Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

Factory wholesale Carbon Monoxide Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

Factory wholesale Carbon Monoxide Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

Factory wholesale Carbon Monoxide Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

Factory wholesale Carbon Monoxide Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures


Related Product Guide:

Our items are commonly identified and trusted by people and can fulfill repeatedly altering economic and social wants of Factory wholesale Carbon Monoxide Gas Detector - Portable gas sampling pump Operating instruction – Huacheng , The product will supply to all over the world, such as: Mexico, Bahrain, Botswana, We set a strict quality control system. We have return and exchange policy, and you can exchange within 7 days after receive the wigs if it is in new station and we service repairing free for our products. Please feel free to contact us for further information and we will offer you competitive price list then.
  • Production management mechanism is completed, quality is guaranteed, high credibility and service let the cooperation is easy, perfect!
    5 Stars By John from New Orleans - 2017.02.14 13:19
    We have been cooperated with this company for many years, the company always ensure timely delivery ,good quality and correct number, we are good partners.
    5 Stars By tobin from Hyderabad - 2018.06.30 17:29
    Write your message here and send it to us

    Related products

    • Low price for Thermometer Rain Gauge - Microcomputer automatic calorimeter – Huacheng

      Low price for Thermometer Rain Gauge - Microco...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Europe style for Measure Temperature And Humidity - Microcomputer automatic calorimeter – Huacheng

      Europe style for Measure Temperature And Humidi...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Factory directly Handheld Portable Phosphine Detection Alarm - Microcomputer automatic calorimeter – Huacheng

      Factory directly Handheld Portable Phosphine De...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • 100% Original Wireless Weather Station With Rain Gauge - Multifunctional Automatic Weather Station – Huacheng

      100% Original Wireless Weather Station With Rai...

      Working environment: -40℃~+70℃; Main functions: Provide 10-minute instantaneous value, hourly instantaneous value, daily report, monthly report, annual report; users can customize the data collection time period; Power supply mode: mains or 12v direct current, and optional solar battery and other power supply modes; Communication interface: standard RS232; GPRS/CDMA; Storage capacity: The lower computer stores data cyclically, and the storage time length of the system service software c...

    • Discount wholesale Micro Analytical Balance - Microcomputer automatic calorimeter – Huacheng

      Discount wholesale Micro Analytical Balance - ...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Popular Design for Sterile Disposable Plastic Serological Pipette - Microcomputer automatic calorimeter – Huacheng

      Popular Design for Sterile Disposable Plastic S...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...