• Factory wholesale Carbon Monoxide Gas Detector - Portable gas sampling pump Operating instruction – Huacheng

Factory wholesale Carbon Monoxide Gas Detector - Portable gas sampling pump Operating instruction – Huacheng

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our advantages are lower prices,dynamic sales team,specialized QC,strong factories,high quality products and services for Ambient Temperature And Humidity Sensor, Dropper, Portable Multi Parameter Water Analysis Kit, For even more data, please do not be reluctant to call us. All inquiries from you may be highly appreciated.
Factory wholesale Carbon Monoxide Gas Detector - Portable gas sampling pump Operating instruction – Huacheng Detail:

● Display: Large screen dot matrix liquid crystal display
● Resolution: 128*64
● Language: English and Chinese
● Shell materials: ABS
● Working principle: Diaphragm self-priming
● Flow: 500mL/min
● Pressure: -60kPa
● Noise: <32dB
● working voltage: 3.7V
● Battery capacity: 2500mAh Li battery
● Stand-by time: 30hours(keep pumping open)
● Charging Voltage: DC5V
● Charging Time: 3~5 hours
● Working temperature: -10~50℃
● Working Humidity: 10~95%RH(non-condensing)
● Dimension: 175*64*35(mm) Excluded pipe size, show in Figure 1.
● Weight: 235g

Outline dimension drawing

Figure 1: Outline dimension drawing

The list of standard products is shown in table 1
Table 1: Standard list

Items

Name

1

Portable gas sampling pump

2

Instruction

3

Charger

4

Certificates

Instrument description
The specification of instrument parts is shown in Figure 2 and table 2

Table 2. Parts specification

Items

Name

Parts specification

Figure 2: Parts specification

1

Display screen

2

USB charging interface

3

Up button

4

Power button

5

Down button

6

Air outlet

7

Air inlet

Connection Description
Portable gas sampling pump is used in conjunction with portable gas detector, uses hosepipe to connect the sampling pump and calibrated cover of gas detector together. Figure 3 is connection schematic diagram.

connection schematic diagram

Figure 3: connection schematic diagram

If the environment to be measured is far away, the hosepipe can be connected at the inlet elbow of the sampling pump.

Starting up
Button description is shown in table 3
Table 3 Button function instruction

Button

Function instruction

Note

Upturn, value+  
 starting Long press 3s starting up
Long press 3s enter menu
Short press to confirm operation
Long press 8s instrument restart
 

Downturn, value-  

● Long press button 3s starting up
● Plug charger, automatic starting of instrument

After starting up, the sampling pump is automatically opened, and the default flow rate is the one set last time. As shown in Figure 4:

Main screen

Figure 4: Main screen

On/off pump
In the main screen, short press button, to switch the pump status, on/off pump. Figure 5 shows the pump off status.

Pump off status

Figure 5: Pump off status

Instruction of main menu
In the main screen, long pressstarting to enter main menu show as Figure 6, press ▲or▼to select function, pressstarting to enter the corresponding function.

Main menu

Figure 6: Main menu

Menu function description:
Setting: setting the time of closing the pump on time, language setting ( Chinese and English)
Calibrate: enter calibration procedure
Shut down: instrument shutdown
Back: returns to the main screen

Setting
Setting at the main menu, press to enter, setting menu show as Figure 7.

Settings menu instruction:
Timing: the timing setting of closing the pump
Language: Chinese and English options
Back: returns to the main menu

Settings menu

Figure 7: Settings menu

Timing
Select timing from the setting menu and press startingbutton to enter. If the timing is not set, it will be displayed as shown in Figure 8:

Timer off

Figure 8: Timer off

Push ▲ button to open timer, push ▲ button again, to increase the time by 10 minutes, and press ▼ button to decrease the time by 10 minutes.

Timer on

Figure 9: Timer on

Press starting button to confirm, will return to the main screen, the main screen is shown in Figure 10, the main screen shows the timing flag, shows the remaining time at the below.

Main screen of setting timer

Figure 10: Main screen of setting timer

When the timing is over, automatically shut down the pump.
If you need to cancel the timing off function, go to the timing menu, and press ▼ button to set the time as 00:00:00 to cancel the timing off.

Language
Enter the language menu, as shown in Figure 11:
Select the language you want to display and press to confirm.

Language setting

Figure 11: Language setting

For example, if you need to switch language to Chinese: select Chinese and press starting to confirm, the screen will be displayed in Chinese.

Calibrate
Calibration need to use a flow meter. Please connect the flow meter to the air inlet of the sampling pump firstly. The connection diagram is shown in Figure. 12. After the connection is completed, perform the following operations for calibration.

Calibration connection diagram

Figure 12: Calibration connection diagram

Select calibration in the main menu and press button to enter calibration procedure. Calibration is two points calibration, the first point is 500mL/min, and the second point is 200mL/min.

The first point 500mL/min calibration
Press ▲ or ▼ button, change the duty cycle of the pump, adjust the flow meter to indicate a flow of 500mL/min. As shown in Figure 13:

Flow adjustment

Figure 13: Flow adjustment

After the adjustment, press starting button to display the storage screen as shown in Figure. 14. Select yes, press starting button to save the setting. If you do not want to save the settings, choose no, press starting to exit calibration.

Storage screen

Figure14: Storage screen

The second point 200mL/min calibration
Then enter the second point of 200mL/min calibration, press ▲ or ▼ button, adjust the flow meter to indicate a flow of 200mL/min, as shown in Figure 15:

Figure 15 Flow adjustment

Figure 15: Flow adjustment

After the adjustment, press starting button to display the storage screen as shown in Figure 16. Select yes, and press starting button to save the settings.

Figure16 Storage screen

Figure16: Storage screen

The calibration completion screen is shown in Figure 17 and then returns to the main screen.

Turn off
Go to the main menu, press ▼ button to select turn off, then press button to turn off.

Figure 17Calibration completion screen

Figure 17: Calibration completion screen

1. Do not use in the environment with high humidity
2. Do not use in the environment with large dust
3. If the instrument is not used for a long time, please charge once every 1 to 2 months.
4. If the battery is removed and reassembled, the device will not be turned on by pressingstarting button. Only by plugging in the charger and activating it, the instrument will turn on normally.
5. If the machine cannot be started or crashed, the instrument will be restarted automatically by long pressing the startingbutton for 8 seconds.


Product detail pictures:

Factory wholesale Carbon Monoxide Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

Factory wholesale Carbon Monoxide Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

Factory wholesale Carbon Monoxide Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

Factory wholesale Carbon Monoxide Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

Factory wholesale Carbon Monoxide Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

Factory wholesale Carbon Monoxide Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

Factory wholesale Carbon Monoxide Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

Factory wholesale Carbon Monoxide Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

Factory wholesale Carbon Monoxide Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

Factory wholesale Carbon Monoxide Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

Factory wholesale Carbon Monoxide Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

Factory wholesale Carbon Monoxide Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

Factory wholesale Carbon Monoxide Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures


Related Product Guide:

carry on to further improve, to guarantee merchandise high-quality in line with market and buyer standard necessities. Our organization has a top quality assurance procedure have already been established for Factory wholesale Carbon Monoxide Gas Detector - Portable gas sampling pump Operating instruction – Huacheng , The product will supply to all over the world, such as: Spain, Jamaica, Irish, We firmly think that we have the full capability to present you contented merchandise. Wish to collect concerns within you and build a new long-term synergy romantic relationship. We all significantly promise:Csame excellent, better selling price; exact selling price, better quality.
  • This company has a lot of ready-made options to choose and also could custom new program according to our demand, which is very nice to meet our needs.
    5 Stars By Constance from Kuwait - 2017.10.27 12:12
    The supplier cooperation attitude is very good, encountered various problems, always willing to cooperate with us, to us as the real God.
    5 Stars By Bella from Singapore - 2017.02.14 13:19
    Write your message here and send it to us

    Related products

    • Factory Free sample Piastic Cup - Microcomputer automatic calorimeter – Huacheng

      Factory Free sample Piastic Cup - Microcompute...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • PriceList for Mobile Weather Station - Small Automatic Weather Station – Huacheng

      PriceList for Mobile Weather Station - Small A...

      Name Measuring range Resolution Resolution Wind speed sensor 0~45m/s 0.1m/s ±(0.3±0.03V)m/s Wind direction sensor 0~360º 1° ±3° Air temperature sensor -50~+100℃ 0.1℃ ±0.5℃ Air temperature sensor 0~100%RH 0.1%RH ±5% Air pressure sensor 10~1100hPa 0.1hpa ±0.3hPa Rain sensor 0~4mm/min 0.2mm ±4% 1. The collector can connect up to 16 sensors, and the specific sensors can be configured according to customer needs, and...

    • Factory best selling Turbidity Meter Portable - Microcomputer automatic calorimeter – Huacheng

      Factory best selling Turbidity Meter Portable -...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • 100% Original Pipette Tip - Microcomputer automatic calorimeter – Huacheng

      100% Original Pipette Tip - Microcomputer auto...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Factory Supply Carbon Monoxide Wireless Gas Detector - Single-point Wall-mounted Gas Alarm – Huacheng

      Factory Supply Carbon Monoxide Wireless Gas Det...

      ● Sensor: catalytic combustion ● Responding time: ≤40s (conventional type) ● Work pattern: continuous operation, high and low alarm point(could be set) ● Analog interface: 4-20mA signal output [option] ● Digital interface: RS485-bus interface [option] ● Display mode: Graphic LCD ● Alarming mode: Audible alarm — above 90dB; Light alarm — High intensity strobes ● Output control: relay output with two way alarming control ● Additional function: time display、calendar display ● Storag...

    • Discount wholesale Sludge Concentration Meter - Microcomputer automatic calorimeter – Huacheng

      Discount wholesale Sludge Concentration Meter -...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...