• Factory wholesale Ambient Temperature Sensor - Soil temperature and humidity sensor soil transmitter – Huacheng

Factory wholesale Ambient Temperature Sensor - Soil temperature and humidity sensor soil transmitter – Huacheng

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We insist on offering high-quality creation with superior business enterprise concept, honest revenue plus the greatest and fast service. it will bring you not only the high quality solution and huge profit, but essentially the most significant is usually to occupy the endless market for Plastic Test Tube Rack, Digital Decibel Meter, Sterile Disposable Plastic Serological Pipette, In our efforts, we already have many shops in China and our products have won praise from customers worldwide. Welcome new and old customers to contact us for the future long term business relationships.
Factory wholesale Ambient Temperature Sensor - Soil temperature and humidity sensor soil transmitter – Huacheng Detail:

Measurement range soil moisture 0 ~ 100% soil temperature -20 ~ 50 ℃
Soil wet resolution 0.1%
Temperature resolution 0.1 ℃
Soil wet accuracy ± 3%
Temperature accuracy ± 0.5 ℃
Power supply mode DC 5V 
DC 12V 
DC 24V 
Other
Output form Current: 4~20mA 
Voltage: 0~2.5V 
Voltage: 0~5V    
RS232
RS485
TTL Level: (frequency; Pulse width)
Other
Load resistance Voltage type: RL≥1K
Current type: RL≤250Ω
Working temperature -50 ℃ ~ 80 ℃
Relative humidity 0 to 100%
Product weight 220 g probe with transmitter 570 g
Product power consumption about 420 mW

Soil humidity:
Voltage type (0 ~ 5V output):
R = V / 5 × 100%
(R is the soil moisture value and V is the output voltage value (V))
Current type (4 ~ 20mA output):
R = (I-4) / 16 × 100%
(R is the soil moisture value, I is the output current value (mA))

Soil temperature:
Voltage type (0 ~ 5V output):
T = V / 5 × 70-20
(T is the measured temperature value (℃), V is the output voltage value (V), this formula corresponds to the measurement range -20 ~ 50 ℃)
Current type (4 ~ 20mA)
T = (I-4) / 16 × 70 -20
(T is the measured temperature value (℃), I is the output current (mA), this formula corresponds to the measurement range -20 ~ 50 ℃)

1. If equipped with a weather station produced by the company, directly connect the sensor to the corresponding interface on the weather station using a sensor line;

2. If the transmitter is purchased separately, the corresponding line sequence of the transmitter is:

Line color Output signal
Voltage Current communication
Red Power + Power + Power +
Black(green) Power ground Power ground Power ground
Yellow Voltage signal Current signal A+/TX
Blue     B-/RX

Transmitter voltage and current output wiring:

Wiring for voltage output mode

Wiring for voltage output mode

Wiring for voltage output mode 1

Wiring for current output mode

Structure Dimensions

Structure Dimensions

Structure Dimensions 1

Sensor Size

1. The serial format
Data bits 8 bits
Stop bit 1 or 2
Check Digit None
Baud rate 9600 Communication interval is at least 1000ms
2. Communication format
[1] Write device address
Send: 00 10 Adress CRC (5 bytes)
Returns: 00 10 CRC (4 bytes)
Note: 1. The address bit of the read and write address command must be 00. 2. Adress is 1 byte and the range is 0-255.
Example: Send 00 10 01 BD C0
Returns 00 10 00 7C
[2] Read device address
Send: 00 20 CRC (4 bytes)
Returns: 00 20 Adress CRC (5 bytes)
Explanation: Adress is 1 byte, the range is 0-255
For example: Send 00 20 00 68
Returns 00 20 01 A9 C0
[3] Read real-time data
Send: Adress 03 00 00 00 02 XX XX
Note: as shown below

Code Function definition Note
Adress Station number (address)  
03 Function code  
00  00 Initial address  
00  02 Read points  
XX XX CRC Check code,front low later high  

Returns: Adress 03 04 XX XX XX XX YY YY
Note

Code Function definition Note
Adress Station number (address)  
03 Function code  
04 Read unit byte  
XX  XX Soil temperature data (high before, low after) Hex
XX  XX Soil humidity data (high before, low after) Hex
YY  YY CRCCheck code  

To calculate the CRC code:
1. The preset 16-bit register is FFFF in hexadecimal (that is, all are 1). Call this register the CRC register.
2. XOR the first 8-bit data with the lower bit of the 16-bit CRC register and put the result in the CRC register.
3. Shift the contents of the register to the right by one bit (toward the low bit), fill the highest bit with 0, and check the lowest bit.
4. If the least significant bit is 0: repeat step 3 (shift again), if the least significant bit is 1: the CRC register is XORed with the polynomial A001 (1010 0000 0000 0001).
5. Repeat steps 3 and 4 until 8 times to the right, so that the entire 8-bit data has been processed.
6. Repeat steps 2 to 5 for the next 8-bit data processing.
7. The CRC register finally obtained is the CRC code.
8. When the CRC result is put into the information frame, the high and low bits are exchanged, and the low bit is first.

Connect the sensor according to the instructions in the wiring method, then insert the probe pins of the sensor into the soil to measure humidity, and turn on the power and the collector switch to obtain the soil temperature and humidity at the measurement point.

1. Please check whether the packaging is intact and check whether the product model is consistent with the selection.
2. Do not connect with power on, and then power on after checking the wiring.
3. Do not arbitrarily change the components or wires that have been soldered when the product leaves the factory.
4. The sensor is a precision device. Please do not disassemble it by yourself or touch the surface of the sensor with sharp objects or corrosive liquids in order to avoid damaging the product.
5. Please keep the verification certificate and certificate of conformity, and return it with the product when repairing.

1. When the output is detected, the display indicates that the value is 0 or is out of range. Check whether there is obstruction from foreign objects. The collector may not be able to obtain the information correctly due to wiring problems. Please check whether the wiring is correct and firm;
2. If it is not the above reasons, please contact the manufacturer.

No Power supply Output Signal Instructions
LF-0008-     Soil temperature and humidity sensor
 
 
5V-   5V power supply
12V-   12V power supply
24V-   24V power supply
YV-   Other power
  V 0-5V
V2 0-2.5V
A1 4-20mA
W1 RS232
W2 RS485
TL TTL
M Pulse
X Other
E.g.:  LF-0008-12V-A1:Soil temperature and humidity sensor 12V power supply, 4-20mA current signal output

Product detail pictures:

Factory wholesale Ambient Temperature Sensor - Soil temperature and humidity sensor soil transmitter – Huacheng detail pictures

Factory wholesale Ambient Temperature Sensor - Soil temperature and humidity sensor soil transmitter – Huacheng detail pictures

Factory wholesale Ambient Temperature Sensor - Soil temperature and humidity sensor soil transmitter – Huacheng detail pictures

Factory wholesale Ambient Temperature Sensor - Soil temperature and humidity sensor soil transmitter – Huacheng detail pictures

Factory wholesale Ambient Temperature Sensor - Soil temperature and humidity sensor soil transmitter – Huacheng detail pictures

Factory wholesale Ambient Temperature Sensor - Soil temperature and humidity sensor soil transmitter – Huacheng detail pictures

Factory wholesale Ambient Temperature Sensor - Soil temperature and humidity sensor soil transmitter – Huacheng detail pictures


Related Product Guide:

Well-run equipment, professional sales team, and better after-sales services; We are also a unified big family, everyone stick to the company value "unification, dedication, tolerance" for Factory wholesale Ambient Temperature Sensor - Soil temperature and humidity sensor soil transmitter – Huacheng , The product will supply to all over the world, such as: Czech republic, Albania, Somalia, We will not only continuously introduce technical guidance of experts from both home and abroad, but also develop the new and advanced products constantly to satisfactorily meet the needs of our clients all over the world.
  • Sales manager is very enthusiastic and professional, gave us a great concessions and product quality is very good,thank you very much!
    5 Stars By Gail from Malta - 2017.11.20 15:58
    This is a very professional wholesaler, we always come to their company for procurement, good quality and cheap.
    5 Stars By Bella from Rome - 2018.09.19 18:37
    Write your message here and send it to us

    Related products

    • Factory made hot-sale Cod Analysis - CLEAN MD110 Ultra-thin Digital Magnetic Stirrer – Huacheng

      Factory made hot-sale Cod Analysis - CLEAN MD1...

      ●60-2000 rpm (500ml H2O) ●LCD screen displays working and setting status ●11mm ultra-thin body, stable and space-saving ●Quiet, no loss, no maintenance ●Clockwise and counterclockwise (automatic) switching ●Off timer setting ●Compliant with CE specifications and does not interfere with electrochemical measurements ●Use environment 0-50°C Rated Voltage 100 – 240VC Rated frequency 50-6Hz Output voltage 12VDC Input power 5W Magnetic Stirrer Quadrupole Drive Coil Display LCD ...

    • China Supplier Pipette Tips Filter - Microcomputer automatic calorimeter – Huacheng

      China Supplier Pipette Tips Filter - Microcomp...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • High Quality for Stratus Professional Rain Gauge - Microcomputer automatic calorimeter – Huacheng

      High Quality for Stratus Professional Rain Gaug...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • 2022 New Style Measuring Cup With Lid - Microcomputer automatic calorimeter – Huacheng

      2022 New Style Measuring Cup With Lid - Microc...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • China wholesale Automatic Rain Detector - Ultrasonic Level Difference Meter – Huacheng

      China wholesale Automatic Rain Detector - Ultr...

      ● Stable and reliable: We choose high-quality modules from the power supply part in circuit design, and select high-stable and reliable devices for the procurement of key components; ● Patented technology: Ultrasonic intelligent technology software can perform intelligent echo analysis without any debugging and other special steps. This technology has the functions of dynamic thinking and dynamic analysis; ● High precision: The ultrasonic level gauge has high precision, and the liquefaction p...

    • Best Price for Temperature Humidity And Pressure Sensor - LF-0010 TBQ Total Radiation Sensor – Huacheng

      Best Price for Temperature Humidity And Pressur...

      This sensor is used to measure the spectral range of 0.3-3μm, solar radiation, can also be used to measure the incident solar radiation to the slant of the reflected radiation can be measured, such as the induction downwardly facing, light shielding ring measurable scattered radiation. Therefore, it can be widely applied to the use of solar energy, meteorology, agriculture, building materials, aging and atmospheric pollution and other departments to do the measurement of solar radiation energ...