• Factory Supply Carbon Monoxide Wireless Gas Detector -  Digital gas transmitter Instruction Manual – Huacheng

Factory Supply Carbon Monoxide Wireless Gas Detector - Digital gas transmitter Instruction Manual – Huacheng

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Fast and great quotations, informed advisers to help you choose the correct solution that suits all your requirements, a short creation time, responsible top quality manage and distinct providers for paying and shipping affairs for Noise Level Meter, Standard Vessels, Outdoor Ambient Temperature Sensor, Thanks for taking your valuable time to visit us and look forward to have a nice cooperation with you.
Factory Supply Carbon Monoxide Wireless Gas Detector - Digital gas transmitter Instruction Manual – Huacheng Detail:

1. Detection principle: This system through standard DC 24V power supply, real-time display and output standard 4-20mA current signal, analysis and processing to complete digital display and alarm operation.
2. Applicable objects: This system supports the standard sensor input signals. Table 1 is our gas parameters setting table (For reference only, users can set the parameters according to the needs)
Table 1 Conventional gas parameters

Detected gas Measure Range Resolution Low/High Alarm Point
EX 0-100%lel 1%lel 25%lel   /50%lel
O2 0-30%vol 0.1%vol <18%vol, >23%vol
N2 70-100%vol 0.1%vol >82%vol, <90%vol
H2S 0-200ppm 1ppm 5ppm  /10ppm
CO 0-1000ppm 1ppm 50ppm  /150ppm
CO2 0-50000ppm 1ppm 2000ppm /5000ppm
NO 0-250ppm 1ppm 10ppm  /20ppm
NO2 0-20ppm 1ppm 5ppm  /10ppm
SO2 0-100ppm 1ppm 1ppm   /5ppm
CL2 0-20ppm 1ppm 2ppm  /4ppm
H2 0-1000ppm 1ppm 35ppm / 70ppm
NH3 0-200ppm 1ppm 35ppm / 70ppm
PH3 0-20ppm 1ppm 1ppm / 2ppm
HCL 0-20ppm 1ppm 2ppm   /4ppm
O3 0-50ppm 1ppm 2ppm   /4ppm
CH2O 0-100ppm 1ppm 5ppm   /10ppm
HF 0-10ppm 1ppm 5ppm   /10ppm
VOC 0-100ppm 1ppm 10ppm   /20ppm

3. Sensor models: Infrared sensor/catalytic sensor/electrochemical sensor
4. Response time: ≤30 seconds
5. Working voltage: DC 24V
6. Using environment: Temperature: – 10 ℃ to 50 ℃
Humidity < 95%( No condensation)
7. System power: maximum power 1 W
8. Output current: 4-20 mA current output
9. Relay control port: Passive output, Max 3A/250V
10. Protection level: IP65
11. Explosion-proof certificate number: CE20,1671, Es d II C T6 Gb
12. Dimensions: 10.3 x 10.5cm
13. System connecting requirements: 3 wire connection, single wire diameter 1.0 mm or more, line length 1km or less.

Display transmitter’s factory appearance is like figure 1, there has mounting holes on the transmitter rear panel. The user only need to connect line and other actuator with the corresponding port according to the manual, and connect DC24V power, then it can work.

3.Transmitter Usage

Figure 1 Appearance

The internal wiring of the instrument is divided into display panel (upper panel) and bottom panel (lower panel). Users only need to connect the wiring on the bottom plate correctly.
Figure 2 is the diagram of the transmitter wiring board. There are three groups of wiring terminals, power communication interface, alarm lamp interface and relay interface.

Figure 2 Internal structure

Figure 2 Internal structure

Client interface connection:
(1)Power signal interface: “GND”, “Signal” , “+24V”. The signal export 4-20 mA
4-20mA transmitter wiring is like figure 3.

Figure 3 Wiring illustration

Figure 3 Wiring illustration

Note: For illustration only, the terminal sequence is not consistent with the actual equipment.
(2)Relay interface: provide a passive switch export, always open, alarm relay pull up. Use as needed.Maximum support 3A/250V.
Relay wiring is like figure 4.

Figure 4 Relay wiring

Figure 4 Relay wiring

Notice: It is need to connect AC contactor if user connect big power control device.

5.1 Panel description

As shown in Figure 5, The transmitter panel is composed of a concentration indicator, a digital tube, a status indicator lamp, a first class alarm indicator lamp, a two level alarm indicator lamp and 5 keys.
This diagram shows the studs between the panel and the bezel, After removing the bezel, observe the 5 buttons on the panel.
Under normal monitoring condition, the status indicator flashes and the digital tube shows the current measurement value. If the alarm situation occurs, the alarm light indicates level 1 or 2 alarm, and the relay will attract.

Figure 5 Panel

Figure 5 Panel

5.2 User instructions
1. Operation procedure
Set parameters
First step: Press the settings button, and the system displays 0000

User instructions

Second steps: Input password (1111 is password). The up or down button allows you to select between 0 and 9 bits, press the settings button to select the next one in turn, Then, select the numbers by using the “up” button
Third steps: After input password, press the “OK” button, if the password is correct then the system will enter the function menu, digital tube display F-01, through the “turn on” key to select the function of F-01 to F-06, all the functions in the function table 2. For example, after selecting the function item F-01, press the “OK” button, and then enter the first level alarm setting, and the user can set the alarm at the first level. When the setting is complete, press the OK key, and the system will display F-01. If you want to continue setting, repeat the above steps, or you can press the return key to exit this setting.
The function is shown in table 2:
Table 2 Function description

Function

Instruction

Note

F-01

Primary alarm value

R/W

F-02

Second alarm value

R/W

F-03

Range

R

F-04

Resolution ratio

R

F-05

Unit

R

F-06

Gas type

R

2. Functional details
● F-01 Primary alarm value
Change the value through the “up” button, and switch the position of the digital tube flashing through the “Settings” key. Press OK to save settings.
● F-02 Second alarm value
Change the value through the “up” button, and switch the position of the digital tube flashing through the “Settings” key.
Press OK to save settings.
● F-03 Range Values(Factory has been set, please do not change)
Maximum value of instrument measurement
● F-04 Resolution ratio (Only read)
1 for integers, 0.1 for one decimal, and 0.01 for two decimal places.

Functional details

● F-05 Unit settings(Only read)
P is ppm, L is %LEL, and U is %vol.

 F-05 Unit settings(Only read)F-05 Unit settings(Only read)2

● F-06 Gas type(Only read)
Digital Tube Display CO2
3. Error code description
● E-01 Over full scale
5.3 User operation Precautions
In the process, the user will set the parameters, 30 seconds without pressing any key, the system will exit the environment of setting parameters, back to the detection mode.
Note: This transmitter does not support calibration operation.

6. Common faults and handling methods
(1) System no response after power is applied. Solution: Check whether the system has electricity.
(2) Gas stable display value is beating. Solution: Check if the sensor connector is loose.
(3) If you find the digital display is not normal, turn off the power a few seconds later, then turn on.

1. Before using the instrument, please read the manual carefully.
2. The instrument must be operated in accordance with the rules specified in the instructions.
3. The maintenance of the equipment and the replacement of parts is responsible for our company or around the repair station.
4. If the user does not follow the above instructions without authorization to start repairing or replacing parts, the reliability of the instrument is responsible for the operator.

The use of the instrument should also comply with the relevant domestic departments and factories within the instrument management laws and regulations.


Product detail pictures:

Factory Supply Carbon Monoxide Wireless Gas Detector -  Digital gas transmitter Instruction Manual – Huacheng detail pictures

Factory Supply Carbon Monoxide Wireless Gas Detector -  Digital gas transmitter Instruction Manual – Huacheng detail pictures

Factory Supply Carbon Monoxide Wireless Gas Detector -  Digital gas transmitter Instruction Manual – Huacheng detail pictures

Factory Supply Carbon Monoxide Wireless Gas Detector -  Digital gas transmitter Instruction Manual – Huacheng detail pictures

Factory Supply Carbon Monoxide Wireless Gas Detector -  Digital gas transmitter Instruction Manual – Huacheng detail pictures

Factory Supply Carbon Monoxide Wireless Gas Detector -  Digital gas transmitter Instruction Manual – Huacheng detail pictures

Factory Supply Carbon Monoxide Wireless Gas Detector -  Digital gas transmitter Instruction Manual – Huacheng detail pictures

Factory Supply Carbon Monoxide Wireless Gas Detector -  Digital gas transmitter Instruction Manual – Huacheng detail pictures

Factory Supply Carbon Monoxide Wireless Gas Detector -  Digital gas transmitter Instruction Manual – Huacheng detail pictures

Factory Supply Carbon Monoxide Wireless Gas Detector -  Digital gas transmitter Instruction Manual – Huacheng detail pictures


Related Product Guide:

We thinks what buyers think, the urgency of urgency to act during the interests of a purchaser position of theory, allowing for much better high-quality, reduced processing costs, charges are more reasonable, won the new and outdated consumers the support and affirmation for Factory Supply Carbon Monoxide Wireless Gas Detector - Digital gas transmitter Instruction Manual – Huacheng , The product will supply to all over the world, such as: Slovak Republic, Iceland, Leicester, Since the establishment of our company, we have realized the importance of providing good quality products and the best before-sales and after-sales services. Most problems between global suppliers and clients are due to poor communication. Culturally, suppliers can be reluctant to question things they do not understand. We break down those barriers to ensure you get what you want to the level you expect, when you want it.
  • It can be said that this is a best producer we encountered in China in this industry, we feel lucky to work with so excellent manufacturer.
    5 Stars By Poppy from Tunisia - 2018.06.28 19:27
    The product classification is very detailed that can be very accurate to meet our demand, a professional wholesaler.
    5 Stars By Eric from Guatemala - 2018.12.05 13:53
    Write your message here and send it to us

    Related products

    • China Gold Supplier for Laboratory Electric Balance - Microcomputer automatic calorimeter – Huacheng

      China Gold Supplier for Laboratory Electric Bal...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Best Price on  Air Pressure Sensor Module - Rain sensor stainless steel outdoor hydrological station – Huacheng

      Best Price on Air Pressure Sensor Module - Ra...

      Water-carrying caliber Ф200 ± 0.6mm Measuring range ≤4mm / min (precipitation intensity) Resolution 0.2mm (6.28ml) Accuracy ± 4% (indoor static test, rain intensity is 2mm / min) Power supply mode DC 5V  DC 12V  DC 24V  Other Output form Current 4 ~ 20mA Switching signal: On-off of reed switch Voltage: 0~2.5V  Voltage: 0~5V     Voltage 1 ~ 5V Other Instrument line length Standard: 5 meters Other Working temperature 0 ~ 50 ℃ Storage temperature -10 ℃ ~ ...

    • China Cheap price Air Temperature Sensor - Meteorological anemometer wind speed sensor – Huacheng

      China Cheap price Air Temperature Sensor - Met...

      Measurement range 0~45m/s  0~70m/s Accuracy ±(0.3+0.03V)m/s (V: wind speed) Resolution 0.1m/s Staring wind speed ≤0.5m/s Power supply mode DC 5V  DC 12V  DC 24V  Other Out-put Current: 4~20mA  Voltage: 0~2.5V  Pulse:Pulse signal Voltage: 0~5V     RS232 RS485 TTL Level: (frequency; Pulse width) Other Instrument Line length Standard: 2.5m Other   Load capacity Current mode impedance≤600Ω Voltage mode impedance≥1KΩ Operating environment Temperat...

    • Wholesale Price China Soil Temperature Sensor - Rain sensor stainless steel outdoor hydrological station – Huacheng

      Wholesale Price China Soil Temperature Sensor -...

      Water-carrying caliber Ф200 ± 0.6mm Measuring range ≤4mm / min (precipitation intensity) Resolution 0.2mm (6.28ml) Accuracy ± 4% (indoor static test, rain intensity is 2mm / min) Power supply mode DC 5V  DC 12V  DC 24V  Other Output form Current 4 ~ 20mA Switching signal: On-off of reed switch Voltage: 0~2.5V  Voltage: 0~5V     Voltage 1 ~ 5V Other Instrument line length Standard: 5 meters Other Working temperature 0 ~ 50 ℃ Storage temperature -10 ℃ ~ ...

    • Cheap PriceList for Barometric Sensor - LF-0010 TBQ Total Radiation Sensor – Huacheng

      Cheap PriceList for Barometric Sensor - LF-001...

      This sensor is used to measure the spectral range of 0.3-3μm, solar radiation, can also be used to measure the incident solar radiation to the slant of the reflected radiation can be measured, such as the induction downwardly facing, light shielding ring measurable scattered radiation. Therefore, it can be widely applied to the use of solar energy, meteorology, agriculture, building materials, aging and atmospheric pollution and other departments to do the measurement of solar radiation energ...

    • 18 Years Factory Laboratory Glassware - Microcomputer automatic calorimeter – Huacheng

      18 Years Factory Laboratory Glassware - Microc...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...