• Chinese wholesale Barometric Pressure Sensor - LF-0020 water temperature sensor – Huacheng

Chinese wholesale Barometric Pressure Sensor - LF-0020 water temperature sensor – Huacheng

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Like a result of ours specialty and repair consciousness, our enterprise has won a superb popularity amid buyers everywhere in the environment for Plastic Dropper Cap, Centrifuge Tube, Portable Ultrasonic Water Flow Meter, We sincerely hope to serve you and your business with a good start. If there is anything we can do for You, we shall be more than pleased to do so. Welcome to our factory for visit.
Chinese wholesale Barometric Pressure Sensor - LF-0020 water temperature sensor – Huacheng Detail:

Measurement range -50~100℃
-20~50℃
Accuracy ±0.5℃
Power supply DC 2.5V 
DC 5V 
DC 12V 
DC 24V 
Other
Out-put Current: 4~20mA 
Voltage: 0~2.5V 
Voltage: 0~5V    
RS232
RS485
TTL Level: (frequency; Pulse width)
Other
Line length Standard: 10 meters
Other  
Load capacity Current output impedance≤300Ω
Voltage output impedance≥1KΩ
Operating environment Temperature: -50℃~80℃
Humidity: ≤100%RH    
Produce weight Probe 145 g, with collector 550 g
Power dissipation 0.5 mW

Voltage type (0~5V):
T=V / 5 × 70 -20
(T is the measured temperature value (℃), V is the output voltage (V), this formula corresponds to the measurement range -20 ~ 50 ℃)
T=V / 5 × 150 -50
(T is the measured temperature value (℃), V is the output voltage (V), this formula corresponds to the measurement range -50 ~ 100 ℃)
Current type (4~20mA)
T=(I-4)/ 16 × 70 -20
(T is the measurement temperature value (℃), I is the output current (mA), this type corresponds to the measurement range -20 ~ 50 ℃)
T=(I-4)/ 16 × 150 -50
(T is the measured temperature value (℃), I is the output current (mA), this formula corresponds to the measurement range -50 ~ 100 ℃)
Note: The calculation formulas corresponding to different signal outputs and different measurement ranges need to be recalculated!

1. If equipped with a weather station produced by our company, directly connect the sensor to the corresponding interface on the weather station using the sensor cable.
2. If the transmitter is purchased separately, the matching cable sequence of the transmitter is:

Line color

Output signal

Voltage type

Current type

Communication type

Red

Power+

Power+

Power+

Black (green)

Power ground

Power ground

Power ground

Yellow

Voltage signal

Current signal

A+/TX

Blue

 

 

B-/RX

3. Transmitter voltage and current output wiring:

LF-0020 water temperature sensor5

Wiring for voltage output mode 

LF-0020 water temperature sensor6

Wiring for current output mode

LF-0020 water temperature sensor7

(Water temperature sensor)

LF-0020 water temperature sensor8

(Water temperature sensor)

1. The serial format
Data bits 8 bits
Stop bit 1 or 2
Check Digit None
Baud rate 9600 Communication interval is at least 1000ms
2. Communication format
[1] Write device address
Send: 00 10 Adress CRC (5 bytes)
Returns: 00 10 CRC (4 bytes)
Note: 1. The address bit of the read and write address command must be 00.
2. Adress is 1 byte and the range is 0-255.
Example: Send 00 10 01 BD C0
Returns 00 10 00 7C
[2] Read device address
Send: 00 20 CRC (4 bytes)
Returns: 00 20 Adress CRC (5 bytes)
Explanation: Adress is 1 byte, the range is 0-255
For example: Send 00 20 00 68
Returns 00 20 01 A9 C0
[3] Read real-time data
Send: Adress 03 00 00 00 02 XX XX
Note: as shown below:

Code

Function definition

Note

Adress

Station number (address)

 

03

Function code

 

00  00

Initial address

 

00  01

Read points

 

XX XX

CRC Check code,front low later high

 

Returns: Adress 03 02 XX XX XX XX

Code

Function definition

Note

Adress

Station number (address)

 

03

Function code

 

02

Read unit byte

 

XX  XX

Soil temperature data (high before, low after)

Hex

XX  XX

Soil humidity data (high before, low after)

 

To calculate the CRC code:
1. The preset 16-bit register is FFFF in hexadecimal (that is, all are 1). Call this register the CRC register.
2. XOR the first 8-bit data with the lower bit of the 16-bit CRC register and put the result in the CRC register.
3. Shift the contents of the register to the right by one bit (toward the low bit), fill the highest bit with 0, and check the lowest bit.
4. If the least significant bit is 0: repeat step 3 (shift again), if the least significant bit is 1: the CRC register is XORed with the polynomial A001 (1010 0000 0000 0001).
5. Repeat steps 3 and 4 until 8 times to the right, so that the entire 8-bit data has been processed.
6. Repeat steps 2 to 5 for the next 8-bit data processing.
7. The CRC register finally obtained is the CRC code.
8. When the CRC result is put into the information frame, the high and low bits are exchanged, and the low bit is first.

LF-0020 water temperature sensor9

Connect the sensor according to the instructions in the wiring method, and then insert the sensor probe into the soil to measure the temperature, and supply power to the collector and the sensor to obtain the water temperature at the measurement point.  

1. Please check whether the packaging is intact and check whether the product model is consistent with the selection.
2. Do not connect with power on, and then power on after checking the wiring.
3. Do not arbitrarily change the components or wires that have been soldered when the product leaves the factory.
4. The sensor is a precision device. Please do not disassemble it by yourself or touch the surface of the sensor with sharp objects or corrosive liquids in order to avoid damaging the product.
5. Please keep the verification certificate and certificate of conformity, and return it with the product when repairing.

1. When the output is detected, the display indicates that the value is 0 or is out of range. Check whether there is obstruction from foreign objects. The collector may not be able to obtain the information correctly due to wiring problems. Please check whether the wiring is correct and firm.
2. If it is not the above reasons, please contact the manufacturer.

Number

Power supply mode

Output signal

Explain

LF-0020

 

 

Water temperature sensor

 

5V-

 

5V powered

12V-

 

12V powered

24V-

 

24V powered

YV-

 

Other powered

 

0

No change

V

0-5V

V1

1-5V

V2

0-2.5V

A1

4-20mA

A2

0-20mA

W1

RS232

W2

RS485

TL

TTL

M

Pulse

X

Other

For example: LF-0020-24V-A1: water temperature sensor (transmitter)

24V power supply, 4-20mA output


Product detail pictures:

Chinese wholesale Barometric Pressure Sensor - LF-0020 water temperature sensor – Huacheng detail pictures

Chinese wholesale Barometric Pressure Sensor - LF-0020 water temperature sensor – Huacheng detail pictures

Chinese wholesale Barometric Pressure Sensor - LF-0020 water temperature sensor – Huacheng detail pictures

Chinese wholesale Barometric Pressure Sensor - LF-0020 water temperature sensor – Huacheng detail pictures

Chinese wholesale Barometric Pressure Sensor - LF-0020 water temperature sensor – Huacheng detail pictures


Related Product Guide:

We're going to commit ourselves to giving our esteemed customers along with the most enthusiastically considerate providers for Chinese wholesale Barometric Pressure Sensor - LF-0020 water temperature sensor – Huacheng , The product will supply to all over the world, such as: Sweden, Ireland, Botswana, We aim to build a famous brand which can influence a certain group of people and light up the whole world. We want our staff to realize self-reliance, then achieve financial freedom, lastly obtain time and spiritual freedom. We do not focus on how much fortune we can make, instead we aim to obtain high reputation and be recognized for our goods. As a result, our happiness comes from our clients satisfaction rather than how much money we earn. Ours team will do best for you personally always.
  • This is a honest and trustworthy company, technology and equipment are very advanced and the prodduct is very adequate, there is no worry in the suppliment.
    5 Stars By Elaine from Honduras - 2017.03.08 14:45
    The product classification is very detailed that can be very accurate to meet our demand, a professional wholesaler.
    5 Stars By mary rash from Philippines - 2017.11.29 11:09
    Write your message here and send it to us

    Related products

    • OEM China Fume Hood - Microcomputer automatic calorimeter – Huacheng

      OEM China Fume Hood - Microcomputer automatic ...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Original Factory Ultrasonic Level Gauge - Laboratory products support custom laboratory various instruments and equipment – Huacheng

      Original Factory Ultrasonic Level Gauge - Labo...

    • Ordinary Discount Concrete V Shape Funnel - Microcomputer automatic calorimeter – Huacheng

      Ordinary Discount Concrete V Shape Funnel - Mi...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • 8 Year Exporter Air Pressure Transducer Sensor - Rain sensor stainless steel outdoor hydrological station – Huacheng

      8 Year Exporter Air Pressure Transducer Sensor ...

      Water-carrying caliber Ф200 ± 0.6mm Measuring range ≤4mm / min (precipitation intensity) Resolution 0.2mm (6.28ml) Accuracy ± 4% (indoor static test, rain intensity is 2mm / min) Power supply mode DC 5V  DC 12V  DC 24V  Other Output form Current 4 ~ 20mA Switching signal: On-off of reed switch Voltage: 0~2.5V  Voltage: 0~5V     Voltage 1 ~ 5V Other Instrument line length Standard: 5 meters Other Working temperature 0 ~ 50 ℃ Storage temperature -10 ℃ ~ ...

    • Factory Price For Vehicle Outside Temperature Sensor - LF-0020 water temperature sensor – Huacheng

      Factory Price For Vehicle Outside Temperature S...

      Measurement range -50~100℃ -20~50℃ Accuracy ±0.5℃ Power supply DC 2.5V  DC 5V  DC 12V  DC 24V  Other Out-put Current: 4~20mA  Voltage: 0~2.5V  Voltage: 0~5V     RS232 RS485 TTL Level: (frequency; Pulse width) Other Line length Standard: 10 meters Other   Load capacity Current output impedance≤300Ω Voltage output impedance≥1KΩ Operating environment Temperature: -50℃~80℃ Humidity: ≤100%RH     Produce weight Probe 145 g, with collector 550 g P...

    • Free sample for Disposable Capillary Pipette - Microcomputer automatic calorimeter – Huacheng

      Free sample for Disposable Capillary Pipette -...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...