• Chinese Professional Decibel Meter - Microcomputer automatic calorimeter – Huacheng

Chinese Professional Decibel Meter - Microcomputer automatic calorimeter – Huacheng

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

It is our responsibility to meet your needs and efficiently serve you. Your satisfaction is our best reward. We are looking forward to your visit for joint growth for Universal Rain Sensor, Cod Bod Analyzer, Chemical Oxygen Demand Reagents, Our products are strictly inspected before exporting , So we gain a good reputation all over the world. We looking forward to cooperation with you in the future.
Chinese Professional Decibel Meter - Microcomputer automatic calorimeter – Huacheng Detail:

Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials.

In line with GB/T213-2008 “Coal thermal determination Method”

GB/T384 “Determination of calorific value of petroleum products”

JC/T1005-2006 “Cement black raw material calorific value determination method”

ASTM D5865-2010 “Test Method for Total Calorific Value of Coal and Coking Coal”

GB/T30727-2014 “Solid biomass fuel calorific value determination method”

ISO 1928-2009 “Solid mineral Fuels – Determination of Total Value and Calculation of Net Calorific Value by bomb Calorimeter” requirements.

● It is mainly composed of constant temperature calorimetry system and single-chip microcomputer control system. It is a highly automatic heat measuring instrument controlled by single-chip microcomputer system and capable of data processing.

● The instrument is mainly used for coal, petroleum, chemical, food, wood and other combustible material calorific value measurement, in the measurement of the barrel calorific value at the same time conversion of the corresponding high calorific value and low calorific value.

Adopt American technology touch type LCD screen, integral installation method, ensure the firmness of touch screen.

Infrared technology, CRT display material to make the touch screen more durable. Multi-layer composite film cover, ensure color distortion, reflection and clarity to achieve the best state, sensitive induction, high positioning accuracy, effective infested area up to 90% wear resistance, life can be up to 10 years.

Chinese characters display, without external computer, can be operated directly. Can store more than 1000 data, display heating curve.

Adopt advanced single chip microcomputer system, the operation is fully automatic, the manual need to do is weighing, loading and oxygen, the instrument automatically complete quantitative water injection, automatic mixing, ignition, output printing results, drainage and other work.

Reasonable structure, reliable performance, low failure rate. The results are accurate and the unique cooling correction system ensures the stability of the instrument performance for a long time.

● Controlled by microcomputer, can provide reports of coal quality, man-machine interaction, namely learning. Automatic water injection, drainage, no need to adjust the water temperature, just install the oxygen bomb into the barrel, the instrument will automatically complete all the testing work.

● Accurate structure, unique cooling correction system, to ensure long-term stability of instrument performance. Electronic refrigeration process, completely not affected by environmental temperature changes, to ensure that the temperature difference between the inside and outside of the instrument meets the requirements of the national standard. Can work continuously for a long time.

● Fast test speed, test period ≤8min(rapid method) ≤15min, repeatability and reproducibility of calorific value test in line with GB/T384 “Determination of calorific value of Petroleum Products” standard, GB/T213-2008 “Coal calorific value determination Method” requirements.

The product provides excellent performance and reliability even in harsh environments.

● High degree of automation, automatic use of built-in fixed container bucket water, automatic control of the temperature difference between the inside and outside of the instrument bucket, automatic completion of the whole process of the test.

Rich data processing functions, users can easily query historical test data, data of the day, parallel sample data, etc.
Three, technical parameters:

Heat capacity about 10500 J/K
Temperature range 0~60 ℃
Oxygen bomb capacity 300ml
Response time < 4 S
Oxygen pressure 2.8~3.2 MPa
Resolution 0.0001 ℃
Pressure performance water pressure 20MPa
Linearity <0.08% within the range of temperature rise every 5℃
Weight 25 Kg
Temperature measurement error accuracy ±0.003℃ for every 5℃ temperature rise range
Dimensions 660mm×500mm×500mm
Supply voltage AC220V±10%
Humidity 80% or less
Power 30 w
Ignition voltage AC24V
Ignition time 5S

Product detail pictures:

Chinese Professional Decibel Meter - Microcomputer automatic calorimeter – Huacheng detail pictures


Related Product Guide:

Our development depends on the advanced equipment ,excellent talents and continuously strengthened technology forces for Chinese Professional Decibel Meter - Microcomputer automatic calorimeter – Huacheng , The product will supply to all over the world, such as: Israel, Japan, Slovakia, Hard work to keep making progress, innovation in the industry, make every effort to first-class enterprise. We try our best to build the scientific management model, to learn abundant professional knowledge, to develop advanced production equipment and production process , to create the first-call quality products, reasonable price , high quality of service , quick delivery , to give you create new value .
  • The factory technical staff gave us a lot of good advice in the cooperation process, this is very good, we are very grateful.
    5 Stars By Ryan from Monaco - 2018.02.12 14:52
    We have been engaged in this industry for many years, we appreciate the work attitude and production capacity of the company, this is a reputable and professional manufacturer.
    5 Stars By Jacqueline from Istanbul - 2018.12.10 19:03
    Write your message here and send it to us

    Related products

    • Short Lead Time for Sensor Atmospheric Pressure - PH Sensor – Huacheng

      Short Lead Time for Sensor Atmospheric Pressure...

      The new-generation PHTRSJ soil pH sensor solves the shortcomings of traditional soil pH that requires professional display instruments, tedious calibration, difficult integration, high power consumption, high price, and difficult to carry. ● New soil pH sensor, realizing online real-time monitoring of soil pH. ● It adopts the most advanced solid dielectric and large-area polytetrafluoroethylene liquid junction, which is not easy to block and maintenance-free. ● High integration, small size, l...

    • Wholesale Price China Hydrogen Sulfide Gas Detector - Single Gas Detector User’s manual – Huacheng

      Wholesale Price China Hydrogen Sulfide Gas Dete...

      For security reasons, the device only by suitably qualified personnel operation and maintenance. Prior to the operation or maintenance, please read and fully manage all solutions to these instructions. Including operations, maintenance of equipment and process methods. And a very important safety precautions. Read the following Cautions before using the detector. Table 1 Cautions Cautions 1. Warning: Unauthorized replacement of replacement parts in order to avoid the impact of the instru...

    • Top Quality Temperature Pressure And Humidity Sensor - Soil temperature and humidity sensor soil transmitter – Huacheng

      Top Quality Temperature Pressure And Humidity S...

      Measurement range soil moisture 0 ~ 100% soil temperature -20 ~ 50 ℃ Soil wet resolution 0.1% Temperature resolution 0.1 ℃ Soil wet accuracy ± 3% Temperature accuracy ± 0.5 ℃ Power supply mode DC 5V  DC 12V  DC 24V  Other Output form Current: 4~20mA  Voltage: 0~2.5V  Voltage: 0~5V     RS232 RS485 TTL Level: (frequency; Pulse width) Other Load resistance Voltage type: RL≥1K Current type: RL≤250Ω Working temperature -50 ℃ ~ 80 ℃ Relative humidity 0 ...

    • OEM/ODM China Total Element Weather Station - LF-0012 handheld weather station – Huacheng

      OEM/ODM China Total Element Weather Station - ...

      LF-0012 handheld weather station is a portable meteorological observation instrument that is convenient to carry, easy to operate, and integrates many meteorological elements. The system uses precision sensors and smart chips to accurately measure the five meteorological elements of wind speed, wind direction, atmospheric pressure, temperature, and humidity. The built-in large-capacity FLASH memory chip can store meteorological data for at least one year: universal USB communication interface...

    • Factory Cheap Hot Sound Level Meter - Microcomputer automatic calorimeter – Huacheng

      Factory Cheap Hot Sound Level Meter - Microcom...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Factory Supply Carbon Monoxide Wireless Gas Detector -  Digital gas transmitter Instruction Manual – Huacheng

      Factory Supply Carbon Monoxide Wireless Gas Det...

      1. Detection principle: This system through standard DC 24V power supply, real-time display and output standard 4-20mA current signal, analysis and processing to complete digital display and alarm operation. 2. Applicable objects: This system supports the standard sensor input signals. Table 1 is our gas parameters setting table (For reference only, users can set the parameters according to the needs) Table 1 Conventional gas parameters Detected gas Measure Range Resolution Low/High Alar...