• China Cheap price Portable Gas Detector - Portable gas sampling pump Operating instruction – Huacheng

China Cheap price Portable Gas Detector - Portable gas sampling pump Operating instruction – Huacheng

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We believe that long expression partnership is often a result of top of the range, value added service, prosperous encounter and personal contact for Rain Water Sensor, Protective Gloves, Temperature And Humidity Table, We sincerely look forward to hearing from you. Give us a opportunity to show you our professionalism and enthusiasm. We have been sincerely welcome excellent friends from numerous circles at dwelling and overseas occur to cooperate!
China Cheap price Portable Gas Detector - Portable gas sampling pump Operating instruction – Huacheng Detail:

● Display: Large screen dot matrix liquid crystal display
● Resolution: 128*64
● Language: English and Chinese
● Shell materials: ABS
● Working principle: Diaphragm self-priming
● Flow: 500mL/min
● Pressure: -60kPa
● Noise: <32dB
● working voltage: 3.7V
● Battery capacity: 2500mAh Li battery
● Stand-by time: 30hours(keep pumping open)
● Charging Voltage: DC5V
● Charging Time: 3~5 hours
● Working temperature: -10~50℃
● Working Humidity: 10~95%RH(non-condensing)
● Dimension: 175*64*35(mm) Excluded pipe size, show in Figure 1.
● Weight: 235g

Outline dimension drawing

Figure 1: Outline dimension drawing

The list of standard products is shown in table 1
Table 1: Standard list

Items

Name

1

Portable gas sampling pump

2

Instruction

3

Charger

4

Certificates

Instrument description
The specification of instrument parts is shown in Figure 2 and table 2

Table 2. Parts specification

Items

Name

Parts specification

Figure 2: Parts specification

1

Display screen

2

USB charging interface

3

Up button

4

Power button

5

Down button

6

Air outlet

7

Air inlet

Connection Description
Portable gas sampling pump is used in conjunction with portable gas detector, uses hosepipe to connect the sampling pump and calibrated cover of gas detector together. Figure 3 is connection schematic diagram.

connection schematic diagram

Figure 3: connection schematic diagram

If the environment to be measured is far away, the hosepipe can be connected at the inlet elbow of the sampling pump.

Starting up
Button description is shown in table 3
Table 3 Button function instruction

Button

Function instruction

Note

Upturn, value+  
 starting Long press 3s starting up
Long press 3s enter menu
Short press to confirm operation
Long press 8s instrument restart
 

Downturn, value-  

● Long press button 3s starting up
● Plug charger, automatic starting of instrument

After starting up, the sampling pump is automatically opened, and the default flow rate is the one set last time. As shown in Figure 4:

Main screen

Figure 4: Main screen

On/off pump
In the main screen, short press button, to switch the pump status, on/off pump. Figure 5 shows the pump off status.

Pump off status

Figure 5: Pump off status

Instruction of main menu
In the main screen, long pressstarting to enter main menu show as Figure 6, press ▲or▼to select function, pressstarting to enter the corresponding function.

Main menu

Figure 6: Main menu

Menu function description:
Setting: setting the time of closing the pump on time, language setting ( Chinese and English)
Calibrate: enter calibration procedure
Shut down: instrument shutdown
Back: returns to the main screen

Setting
Setting at the main menu, press to enter, setting menu show as Figure 7.

Settings menu instruction:
Timing: the timing setting of closing the pump
Language: Chinese and English options
Back: returns to the main menu

Settings menu

Figure 7: Settings menu

Timing
Select timing from the setting menu and press startingbutton to enter. If the timing is not set, it will be displayed as shown in Figure 8:

Timer off

Figure 8: Timer off

Push ▲ button to open timer, push ▲ button again, to increase the time by 10 minutes, and press ▼ button to decrease the time by 10 minutes.

Timer on

Figure 9: Timer on

Press starting button to confirm, will return to the main screen, the main screen is shown in Figure 10, the main screen shows the timing flag, shows the remaining time at the below.

Main screen of setting timer

Figure 10: Main screen of setting timer

When the timing is over, automatically shut down the pump.
If you need to cancel the timing off function, go to the timing menu, and press ▼ button to set the time as 00:00:00 to cancel the timing off.

Language
Enter the language menu, as shown in Figure 11:
Select the language you want to display and press to confirm.

Language setting

Figure 11: Language setting

For example, if you need to switch language to Chinese: select Chinese and press starting to confirm, the screen will be displayed in Chinese.

Calibrate
Calibration need to use a flow meter. Please connect the flow meter to the air inlet of the sampling pump firstly. The connection diagram is shown in Figure. 12. After the connection is completed, perform the following operations for calibration.

Calibration connection diagram

Figure 12: Calibration connection diagram

Select calibration in the main menu and press button to enter calibration procedure. Calibration is two points calibration, the first point is 500mL/min, and the second point is 200mL/min.

The first point 500mL/min calibration
Press ▲ or ▼ button, change the duty cycle of the pump, adjust the flow meter to indicate a flow of 500mL/min. As shown in Figure 13:

Flow adjustment

Figure 13: Flow adjustment

After the adjustment, press starting button to display the storage screen as shown in Figure. 14. Select yes, press starting button to save the setting. If you do not want to save the settings, choose no, press starting to exit calibration.

Storage screen

Figure14: Storage screen

The second point 200mL/min calibration
Then enter the second point of 200mL/min calibration, press ▲ or ▼ button, adjust the flow meter to indicate a flow of 200mL/min, as shown in Figure 15:

Figure 15 Flow adjustment

Figure 15: Flow adjustment

After the adjustment, press starting button to display the storage screen as shown in Figure 16. Select yes, and press starting button to save the settings.

Figure16 Storage screen

Figure16: Storage screen

The calibration completion screen is shown in Figure 17 and then returns to the main screen.

Turn off
Go to the main menu, press ▼ button to select turn off, then press button to turn off.

Figure 17Calibration completion screen

Figure 17: Calibration completion screen

1. Do not use in the environment with high humidity
2. Do not use in the environment with large dust
3. If the instrument is not used for a long time, please charge once every 1 to 2 months.
4. If the battery is removed and reassembled, the device will not be turned on by pressingstarting button. Only by plugging in the charger and activating it, the instrument will turn on normally.
5. If the machine cannot be started or crashed, the instrument will be restarted automatically by long pressing the startingbutton for 8 seconds.


Product detail pictures:

China Cheap price Portable Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

China Cheap price Portable Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

China Cheap price Portable Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

China Cheap price Portable Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

China Cheap price Portable Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

China Cheap price Portable Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

China Cheap price Portable Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

China Cheap price Portable Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

China Cheap price Portable Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

China Cheap price Portable Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

China Cheap price Portable Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

China Cheap price Portable Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures

China Cheap price Portable Gas Detector - Portable gas sampling pump Operating instruction – Huacheng detail pictures


Related Product Guide:

It can be our duty to satisfy your preferences and successfully serve you. Your pleasure is our best reward. We have been looking forward to the go to for joint expansion for China Cheap price Portable Gas Detector - Portable gas sampling pump Operating instruction – Huacheng , The product will supply to all over the world, such as: Italy, South Africa, Sydney, Our company will continue to adhere to the " superior quality, reputable, the user first " principle wholeheartedly. We warmly welcome friends from all walks of life to visit and give guidance, work together and create a brilliant future!
  • The after-sale warranty service is timely and thoughtful, encounter problems can be resolved very quickly, we feel reliable and secure.
    5 Stars By Bernice from Finland - 2018.04.25 16:46
    The goods we received and the sample sales staff display to us have the same quality, it is really a creditable manufacturer.
    5 Stars By Fiona from Angola - 2018.11.04 10:32
    Write your message here and send it to us

    Related products

    • Best quality Integrated Weather Station - Multifunctional Automatic Weather Station – Huacheng

      Best quality Integrated Weather Station - Mult...

      Working environment: -40℃~+70℃; Main functions: Provide 10-minute instantaneous value, hourly instantaneous value, daily report, monthly report, annual report; users can customize the data collection time period; Power supply mode: mains or 12v direct current, and optional solar battery and other power supply modes; Communication interface: standard RS232; GPRS/CDMA; Storage capacity: The lower computer stores data cyclically, and the storage time length of the system service software c...

    • Top Suppliers Mechanical Pipette - Microcomputer automatic calorimeter – Huacheng

      Top Suppliers Mechanical Pipette - Microcomput...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Factory Free sample Outdoor Ambient Temperature Sensor - Soil temperature and humidity sensor soil transmitter – Huacheng

      Factory Free sample Outdoor Ambient Temperature...

      Measurement range soil moisture 0 ~ 100% soil temperature -20 ~ 50 ℃ Soil wet resolution 0.1% Temperature resolution 0.1 ℃ Soil wet accuracy ± 3% Temperature accuracy ± 0.5 ℃ Power supply mode DC 5V  DC 12V  DC 24V  Other Output form Current: 4~20mA  Voltage: 0~2.5V  Voltage: 0~5V     RS232 RS485 TTL Level: (frequency; Pulse width) Other Load resistance Voltage type: RL≥1K Current type: RL≤250Ω Working temperature -50 ℃ ~ 80 ℃ Relative humidity 0 ...

    • Best quality Noise Tester - Microcomputer automatic calorimeter – Huacheng

      Best quality Noise Tester - Microcomputer auto...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Hot-selling Industrial Combustible Gas Methane Alarm - Portable pump suction single gas detector User’s Manual – Huacheng

      Hot-selling Industrial Combustible Gas Methane ...

      System configuration 1. Table1 Material List of Portable pump suction single gas detector Gas Detector USB Charger Please check materials immediately after unpacking. The Standard is necessary accessories. The Optional can be chosen according to your needs. If you have no need to calibrate, set the alarm parameters, or read the alarm record, don’t purchase the optional accessories. System parameter Charging Time: about 3hours~6 hours Charging Voltage: DC5V Service Time: Combustible ...

    • Factory Cheap Hot Portable Liquid Flow Meter - Microcomputer automatic calorimeter – Huacheng

      Factory Cheap Hot Portable Liquid Flow Meter -...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...