We now have a highly efficient crew to deal with inquiries from clients. Our intention is "100% shopper pleasure by our merchandise quality, price tag & our staff service" and take pleasure in a very good standing amongst purchasers. With quite a few factories, we can easily provide a wide vary of Wireless Rain Station, Clean Ph Meter, Graduated Transfer Pipette, The principle of our organization is usually to provide high-quality items, qualified services, and trustworthy communication. Welcome all friends to place trial order for developing a long-term small business relationship.
2022 Good Quality Tbq Solar Radiation Sensor - Rain sensor stainless steel outdoor hydrological station – Huacheng Detail:

Water-carrying caliber Ф200 ± 0.6mm
Measuring range ≤4mm / min (precipitation intensity)
Resolution 0.2mm (6.28ml)
Accuracy ± 4% (indoor static test, rain intensity is 2mm / min)
Power supply mode DC 5V 
DC 12V 
DC 24V 
Other
Output form Current 4 ~ 20mA
Switching signal: On-off of reed switch
Voltage: 0~2.5V 
Voltage: 0~5V    
Voltage 1 ~ 5V
Other
Instrument line length Standard: 5 meters
Other
Working temperature 0 ~ 50 ℃
Storage temperature -10 ℃ ~ 50 ℃

1. If equipped with a weather station produced by the company, directly connect the sensor to the corresponding interface on the weather station using a sensor line;

2. If the sensor is purchased separately, as the sensor outputs a set of switching signals, the cable connector does not matter positive and negative. Connect the sensor to the circuit as shown in the figure.

lf-0004-rain

If the sensor outputs other signals, the corresponding line sequence and function of the conventional sensor are as follows:

Line color Output signal
Voltage Current communication
Red Power + Power + Power +
Black(green) Power ground Power ground Power ground
Yellow Voltage signal Current signal A+/TX
Blue     B-/RX

lf-0004-rain1

Structure Dimensions 

lf-0004-rain2

Transmitter size  

1. the serial format
Data bits 8 bits
Stop bit 1 or 2
Check Digit None
Baud rate 9600 Communication interval is at least 1000ms
2. Communication format
[1] Write device address
Send: 00 10 Adress CRC (5 bytes)
Returns: 00 10 CRC (4 bytes)
Note: 1. The address bit of the read and write address command must be 00.
2. Adress is 1 byte and the range is 0-255.
Example: Send 00 10 01 BD C0
Returns 00 10 00 7C
[2] Read device address
Send: 00 20 CRC (4 bytes)
Returns: 00 20 Adress CRC (5 bytes)
Explanation: Adress is 1 byte, the range is 0-255
For example: Send 00 20 00 68
Returns 00 20 01 A9 C0
[3] Read real-time data
Send: Adress 03 00 00 00 01 XX XX
Note: as shown below:

Code Function definition Note
Adress Station number (address)  
03 Function code  
00  00 Initial address  
00  01 Read points  
XX XX CRC Check code,front low later high  

Returns: Adress 03 02 XX XX XX XX YY YY
Note

Code Function definition Note
Adress Station number (address)  
03 Function code  
02 Read unit byte  
XX  XX Data (high before, low after) Hex
XX  XX CRCCheck code  

To calculate the CRC code:
1. The preset 16-bit register is FFFF in hexadecimal (that is, all are 1). Call this register the CRC register.
2. XOR the first 8-bit data with the lower bit of the 16-bit CRC register and put the result in the CRC register.
3. Shift the contents of the register to the right by one bit (toward the low bit), fill the highest bit with 0, and check the lowest bit。
4. If the least significant bit is 0: repeat step 3 (shift again), if the least significant bit is 1: the CRC register is XORed with the polynomial A001 (1010 0000 0000 0001).
5. Repeat steps 3 and 4 until 8 times to the right, so that the entire 8-bit data has been processed.
6. Repeat steps 2 to 5 for the next 8-bit data processing.
7. The CRC register finally obtained is the CRC code.
8. When the CRC result is put into the information frame, the high and low bits are exchanged, and the low bit is first.

RS485 circuit

1. The installation position of the sensor can be selected on the ground, self-made big tube, iron pillar flange or on the roof of the house according to actual requirements.
2. Adjust the three leveling screws on the chassis to make the level bubble indication level (the bubble stays in the center of the circle), and then slowly tighten the three M8 × 80 fixing expansion screws; if the level bubble changes, you need to readjust.
3. Assemble and fix the sensor as shown in the figure above.
4. After fixing, open the rain bucket and cut off the nylon cable ties on the funnel, slowly inject fresh water into the rain sensor, and observe the turning process of the bucket to check whether the data is received on the acquisition instrument. Finally, quantitative water (60-70mm) is injected. If the data displayed by the acquisition instrument is consistent with the amount of injected water, the instrument is normal, otherwise it must be repaired and adjusted.
5. Avoid disassembling the sensor during installation.

1. Please check whether the packaging is intact and check whether the product model is consistent with the selection.
2. Do not connect line with power on. Only check the wiring and make sure the power is on.
3. The sensor cable length will affect the output signal of the product. Do not arbitrarily place the components or wires that have been soldered when the product leaves the factory. If there is a need for change, please contact the manufacturer.
4. The sensor should be inspected regularly to remove dust, mud, sand, leaves and insects, so as not to block the water flow channel of the upper tube (funnel). The cylindrical filter can be removed and washed with water.
5. There is dirt on the inner wall of the dump bucket, which can be washed with water or alcohol or detergent aqueous solution. It is strictly forbidden to wipe with fingers or other objects, so as not to get oily or scratch the inner wall of the dump bucket.
6. During freezing in winter, the instrument should be stopped and can be taken back to the room.
7. Please save the verification certificate and the certificate of conformity, and return it with the product when repairing.

1. The display meter has no indication. The collector may not be able to obtain the information correctly due to wiring problems. Please check whether the wiring is correct and firm.
2. The displayed value of the display is obviously inconsistent with the actual situation. Please empty the water bucket and refill the bucket with a certain amount of water (60-70mm), and clean the inside wall of the bucket.
3. If it is not the above reasons, please contact the manufacturer.

No Power supply Output Signal Instructions
LF-0004     Rain sensor
  5V-    
12V-    
24V-    
YV-    
  M Switch signal output
V 0-2.5V
V 0-5V
W2 RS485
A1 4-20mA
X Other
E.g.: LF-0014-5V-M: Rain sensor. 5V power supply, switch signal output

Product detail pictures:

2022 Good Quality Tbq Solar Radiation Sensor - Rain sensor stainless steel outdoor hydrological station – Huacheng detail pictures

2022 Good Quality Tbq Solar Radiation Sensor - Rain sensor stainless steel outdoor hydrological station – Huacheng detail pictures

2022 Good Quality Tbq Solar Radiation Sensor - Rain sensor stainless steel outdoor hydrological station – Huacheng detail pictures

2022 Good Quality Tbq Solar Radiation Sensor - Rain sensor stainless steel outdoor hydrological station – Huacheng detail pictures


Related Product Guide:

Our business sticks for the basic principle of "Quality could be the life with the firm, and track record will be the soul of it" for 2022 Good Quality Tbq Solar Radiation Sensor - Rain sensor stainless steel outdoor hydrological station – Huacheng , The product will supply to all over the world, such as: Austria, Grenada, Bulgaria, Our advanced equipment, excellent quality management, research and development ability make our price down. The price we offering may not be the lowest, but we guarantee it is absolutely competitive! Welcome to contact us immediately for future business relationship and mutual success!
  • We are really happy to find such a manufacturer that ensuring product quality at the same time the price is very cheap.
    5 Stars By Andrew from Sydney - 2017.01.28 18:53
    The after-sale warranty service is timely and thoughtful, encounter problems can be resolved very quickly, we feel reliable and secure.
    5 Stars By Eve from Zurich - 2017.06.16 18:23
    Write your message here and send it to us

    Related products

    • Super Lowest Price Rain Gauge Thermometer - Microcomputer automatic calorimeter – Huacheng

      Super Lowest Price Rain Gauge Thermometer - Mi...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Bottom price Weather Station With Barometric Pressure - Miniature Ultrasonic Integrated Sensor – Huacheng

      Bottom price Weather Station With Barometric Pr...

      Top appearance  Frontal appearance     Supply voltage DC12V ±1V Signal output RS485 Protocol Standard MODBUS protocol, baud rate 9600 Power consumption 0.6W Working  temperature -40-80℃ Working humidity 0-100%RH Standard cable length 2.5m Protection class IP65 Wind speed     Measuring range 0-40m/s Measurement accuracy ±0.5+2%FS Resolution 0.01m/s Wind direction     Measuring range 0-359° Measurement acc...

    • Special Design for Mass Air Flow Sensor Temperature - Rain sensor stainless steel outdoor hydrological station – Huacheng

      Special Design for Mass Air Flow Sensor Tempera...

      Water-carrying caliber Ф200 ± 0.6mm Measuring range ≤4mm / min (precipitation intensity) Resolution 0.2mm (6.28ml) Accuracy ± 4% (indoor static test, rain intensity is 2mm / min) Power supply mode DC 5V  DC 12V  DC 24V  Other Output form Current 4 ~ 20mA Switching signal: On-off of reed switch Voltage: 0~2.5V  Voltage: 0~5V     Voltage 1 ~ 5V Other Instrument line length Standard: 5 meters Other Working temperature 0 ~ 50 ℃ Storage temperature -10 ℃ ~ ...

    • Trending Products  Fast Response Air Temperature Sensor - FXB-01 Metal wind vane wind direction sensor wind vane – Huacheng

      Trending Products Fast Response Air Temperatur...

      Customized 3.5-meter-high luminous metal weather vane (customizable stainless steel pole of any height) Overall height: 350mm Pointer length: 1200mm Weight: 4.5kg Note: The support rod is configured by the customer

    • Good Quality Noise Monitoring Station - CLEAN MD110 Ultra-thin Digital Magnetic Stirrer – Huacheng

      Good Quality Noise Monitoring Station - CLEAN ...

      ●60-2000 rpm (500ml H2O) ●LCD screen displays working and setting status ●11mm ultra-thin body, stable and space-saving ●Quiet, no loss, no maintenance ●Clockwise and counterclockwise (automatic) switching ●Off timer setting ●Compliant with CE specifications and does not interfere with electrochemical measurements ●Use environment 0-50°C Rated Voltage 100 – 240VC Rated frequency 50-6Hz Output voltage 12VDC Input power 5W Magnetic Stirrer Quadrupole Drive Coil Display LCD ...

    • One of Hottest for Atmospheric Dew Point - Microcomputer automatic calorimeter – Huacheng

      One of Hottest for Atmospheric Dew Point - Mic...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...